THESE INSTRUCTIONS APPLY TO THE FOLLOWING MODEL:
EDGE REUSABLE CONCRETE ANCHOR
USER INSTRUCTION MANUAL
AFA930301
EN 795:2012 TYPE B
EN 80079-36:2016
EN 80079-37:2016
1. INTRODUCTION: This is classed as Personal Protective Equipment (PPE) by the European PPE
Regulation (EU)2016/425 and has been shown to comply with this Regulation through the Harmonized European Standard
EN 795:2012 Type B.
Edge Concrete Anchor
This Anchor is designed to minimize the risk of /provide protection against the danger of falling from heights. However,
always remember that no item of PPE can provide full protection and care must always be taken while carrying out
the risk related activity.
2. PERFORMANCE AND LIMITATIONS OF USE: The Anchor has been tested in accordance with EN 795:2012 Type B and
has achieved the following performance levels :
EN 795:2012 Type B Test Result / Comment
General Requirements
for Anchor devices
(Clause 4.1)
Static Strength
(Clause 4.4.2.3)
Dynamic Strength
(Clause 4.4.2.2)
Corrosion Resistence
(Clause 4.2.2.1)
(PASS)
No sharp edges (PASS).
Sustained a force of 12 kN for 3 minutes (PASS).
When tested with rigid steel mass of 100 kg, the test mass held after test with
the device remaining stable throughout. (PASS)
No corrosion evident after 48 hours of salt spray testing. (PASS)
3. APPLICATION: This Anchor is designed for fastening into a pre-defined hole of dia. 20 mm. through a drilling depth of
Minimum. The anchorage eye is used as an anchorage point for fall protection equipment.
4. INSPECTION : Visually inspect the system before each use to enusre that it is in a serviceable condition and is operating
correctly. If during inspection, doubts are raised about the safety of the system or a component, these should be replaced
either by the manufacturer or a competent person.
5. PRECAUTIONS:
ŸEnsure the Medical condition of the user does not affect his safety in normal and emergency use.
ŸEnsure that the Anchor is installed directly above the user's head.
ŸEnsure that the equipment is compatible with other items when assembled into a system.
89mm
Please read and understand the manufacturer's instructions for each component or part of the complete system.
Manufacturer's instructions must be followed for proper use, care, and maintenance of this product. These instructions must
be retained and be kept available for the user's reference at all times. Alterations or misuse of this product, or failure to follow
instructions, may result in serious injury or death.
Note: The user is advised to keep this user instructions document for the life of the product.
01
02
A diameter hole of 0.75” (20mm) with
minimum deepness of 3.5” (89mm) is
to be drilled ensuring it to be straight
and perpendicular to the surface. The
drilled hole must have a uniform
diameter with no trace of peaks and
valleys on the inner wall. Clean the
drilled hole by blowing compressed
air.
Now the eye of the anchor can be
used as anchorage point. Connect
the lanyard with the anchor.
Now the anchor is ready to use.
Put your thumb inside the anchor loop and the first two fingers around the trigger
while placing the anchor. Also until the trigger and spring fully compresses, squeeze
the fingers and thumb together. To lock the anchor, release the trigger after inserting
it in the hole at least 3” (76mm) deep.
SQUEEZE THE TRIGGER
RELEASE THE TRIGGER
6. INSTRUCTIONS FOR USAGE : AFA930301
The concrete Anchor (AFA930301) may be attached to the structure by pulling on the spring loaded trigger component.
Spoon Orientation
* Best practice for spoon orientation when
0
loaded 90 to hole.
Load
Best
Load
OK
See Spoon Orientation
PROPER LAODING
See Spoon Orientation
Good
Best
Good
0
0
0
90
0
90
HOLE DRILLING REQUIREMENT CHART
(A)” Minimum distance from edge/corner (B)” Concrete thickness
(B)”
6” (15.3 cm)
12” (30.5 cm)
12” (30.5 cm)
5” (12.7 cm)
03
Anchorage
SRL
Reusable
Concrete
Anchorage
Connector
Fall Arrest
Anchorage
Restraint
Reusable Concrete
Anchorage Connector
Restraint Lanyard
Anchorage
Work Positioning
Back-up
Fall Arrest
System
Reusable
Concrete
Anchorage
Connector
Restraint Lanyard
Reusable Concrete
Anchorage Connector
Anchorage
Anchorage
Anchorage
Reusable Concrete
Anchorage Connector
Back-up
Fall Arrest
System
Reusable Concrete
Anchorage Connector
Suspension Line
Seat Board
Personnel Riding
With the help of trigger grip, one can get fast and easy operation for both installation and removal for added productivity designed
for cured concrete with a compression strength of at least 3000 p.s.i.
To use as a Removable portable anchor point on both vertical and overhead surfaces, as well as in combination with horizontal
lifelines, the EDGE Concrete Anchor has been designed.
04
7. INSTALLATION REQUIREMENTS: For safe effective installation of the Reusable Concrete Anchor, make sure to observe the following
requirements:
Concrete: A compressive strength of 3000 p.s.i. (20.7 MPa) is must for the concrete to secure the anchor. Do not use the Reusable
Concrete Anchor in lightweight concrete, hollow block, grout, stone, wood, steel or any other substrate. The concrete base material must
be at least 5 inches (12.7 cm) thick.
Mounting Hole Location: The thickness and width of the concrete is considered to analyze the allowable distance for mounting the
Reusable Concrete Anchor from an edge or corner. Mounting hole location requirements are as follows:
Ÿ
Ÿ
Concrete Thickness
12 in (30.5 cm)
10 in (25.4 cm)
8 in (20.3 cm)
5 in (12.7 cm)
12 in (30.5 cm)
16 in (40.6 cm)
20 in (50.8 cm)
24 in (61 cm)
6 in (15.3 cm)
8 in (20.3 cm)
10 in (25.4 cm)
12 in (30.5 cm)
Minimum Mounting Distance from Edge/CornerConcrete Width
Note: Drill bits for drilling mounting holes must conform to ISO 5468 addressing carbide-tipped masonry drills
and blanks for carbide-tipped masonry drills.
8. ANCHORAGE STRENGTH: Ensure that the structure on to which the anchor is fitted is strong enough to withstand a load of
20kN.
9. LIMITATION:
ŸIt should be the personal property of its user.
ŸIt should not be used in highly acid or basic environments.
ŸThe equipment shall not be used out side its limitation, or for any purpose other than that for which it is intended.
ŸThe anchor has been tested to EN 795 : 2012 Type B and is appropriate for maximum of single person use with energy
absorber as per EN 355:2002 that is rated to user mass of up to 140kg including tools.
ŸIt is essential for the safety of user that if the product is resold outside the original country of destination, the reseller
shall provide instruction for use, for maintenance, for periodic examination and for repair in the language of the country
in which product is to be used.
ŸIt is advisable to use the dorsal attachment D-Ring of the harness for connection.
ŸA full body harness is the only acceptable body holding device that can be used in fall arrest system.
ŸFollowing conditions may be hazardous & may affect the performance of Anchor -
ŸExtreme temperature.
ŸTrailing or looping of Lanyards over sharp edges.
ŸExtreme acidic or basic environments.
ŸAbrasive or sharp edge structures which can damage the equipment.
ŸChemical Reagents.
ŸClimatic exposure.
ŸWhen the equipment gets wet, either from being in use or when due to cleaning, it should be allowed to dry by itself and
be kept away from open fire or any other source of heat.
ŸWhen Anchor device is used as part of a fall arrest system, the user shall be equipped with a means of limiting the
maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 6 kN.
ŸAny dangers that may arise by the use of combinations of items of equipment in which the safe function of any one item
is affected by or interferes with the safe function of another.
ŸEnsure that the harness used confirms to EN 361 and the Karabiner is connected to attachment elements of the
harness; also ensure that harness has an attachment located appropriately to the fall arrester.
05
ŸIt is essential for safety that the anchor device or anchor point should always be positioned, and the work carried out in
such a way as to minimize both the potential for falls and potential fall distance. Where it is essential that the anchor
device/point is placed above the position of the user, the manufacturer shall make a statement to that effect.
ŸStandard packaging supplied from manufacturer should be used during transportation to protect the equipment against
damage.
ŸIt is important to conduct regular periodic examination of the product because the safety of the user depends upon the
continued efficiency and durability of the product.
ŸThe frequency of examination should be at least once in a year however it can be more than once if legislation requires,
or frequency of use is high or environmental conditions have an adverse effect on it eg. excessive rain, sea side
environment, excessive heat etc.
ŸEnsure that all markings on the product are legible and readable.
ŸAnchor device is marked with the date of the last inspection.
ŸThe anchor device should only be used for personal fall protection equipment and not for lifting equipment.
ŸEnsure that spring movement is well working .
ŸEnsure all the parts are free from rust.
ŸIf there is any crack/damage/deformation shown on the product, it should be removed immediately from the service.
10. COMPATIBILITY: To optimize protection, in some instance it may be necessary to use the anchor with suitable PPE such as:
boots/ gloves/ helmet and ear protection. In this case, before carrying out the risk-related activity, consult your supplier to
ensure that all your protective products are compatible and suitable for your application.
11. REPAIR: If the product becomes damaged, it will NOT provide the optimum level of protection, and therefore should be
immediately removed from service. It needs to be inspected to see if it is replaced or repaired. Never use the damaged
product. Repair is only permitted by the manufacturer or a nominated repair centre or individual approved by the
manufacturer.
12. CLEANING AND MAINTENANCE: In case of minor soiling, wipe the anchor with cotton cloth or a soft brush. Do not use any
0 0
abrasive material. For intensive cleaning wash the anchor in water at a temperature between 30 C to 60 C by using a neutral
0
detergent (pH 7). The washing temperature should not exceed 60 C. Do not use acid or basic detergents.
13. STORAGE AND TRANSPORT: When not in use, store the anchor away from heavily acidic or basic environment. Never
place heavy items on top of it. Store in cool dry place, preferably away from moisture, direct sunlight, chemically hazardous
environment, extra acidic or basic conditions and sharp edges.
14. WITHDRAWAL FROM USE: If the system has been used to arrest a fall, it should be removed from service and returned to
the manufacturer or a competent repair centre for servicing and re-test.
15. WARNING:
ŸDo not make any alteration or additions to the equipment without the manufacturer’s prior written consent and repair
shall only be carried out by personnel trained by the manufacture & duly authorized by him.
The Anchor is marked with
i)
requirements of the PPE Regulation (EU)2016/425
ii) Identification of the manufacturer
iii) Type or product code
iv) Minimum Breaking Strength
v) UID for traceability of Product
vi) Norm Reference.
vii) Read The Instruction Before Use.
viii) For single user only
(ix) Atex marking.
The CE mark showing that the product meets the
UID: XXXXXXXXXXXX
(iv)
(v)
(i)
(ix)
(ii)
(vi)
(viii)
(iii)
(vii)
AKS/AFA930301/280121/V1
Certification Body :
SATRA Technology Europe Ltd, Bracetown Business Park, Clonee, Dublin D15 YN2P Ireland (Notified Body 2777)
Ongoing Assessment Body:
SGS Fimko Oy, Takomotie 8, FI-00380 Helsinki, Finland (Notified Body 0598)
www.kstrong.com
USA South America ASIA
KStrong Inc.
150 N. Radnor Chester Road Suite F200
Radnor, Pennsylvania 19087 United States
Contact number : 1-833-KSTRONG
For EU Declaration, please visit https://kstrong.com/asia/eu-declaration-form/
LIFESPAN: The estimated product Lifespan is 10 years from the date of manufacture. The following factors can reduce the
Lifespan of the product: intense use, contact with chemical substances, specially aggressive environments, extreme
temperature exposure, UV exposure, abrasions, cuts, violent impacts, bad use or maintenance.
DISCLAIMER: Prior to use, the end user must read and understand the manufacturer's instructions supplied with this product
at the time of shipment and seek training from their employer's trained personnel on the proper usage of the product.
Manufacturer is not liable or responsible for any loss, damage or injury caused or incurred by any person on grounds of
improper usage or installation of this product.
Periodic examination
next due date
Product
Model & type/Identification
Trade Name
Address
Identification number
Manufacturer
Tel, email into use
Year of manufacture
Purchase Date
Date first put into use
Other relevant information (eg. document number)
PERIODIC EXAMINATION AND REPAIR HISTORY
Date
Name and signature
of competent person
Reason for entry
(periodic examination
or repair)
Defects noted, repairs
relevant information
carried out and other
EQUIPMENT RECORD

Other KStrong Winch manuals

KStrong AFT75108 Operator's manual

KStrong

KStrong AFT75108 Operator's manual

KStrong AFT730042 Operator's manual

KStrong

KStrong AFT730042 Operator's manual

KStrong AFT730020 Operator's manual

KStrong

KStrong AFT730020 Operator's manual

KStrong AFT730020 Operator's manual

KStrong

KStrong AFT730020 Operator's manual

Popular Winch manuals by other brands

TOHO S Series instruction manual

TOHO

TOHO S Series instruction manual

Westin T-MAX EW-8500 Fitting instructions

Westin

Westin T-MAX EW-8500 Fitting instructions

AL-KO 351 Instructions for use

AL-KO

AL-KO 351 Instructions for use

Tractel caRol TR150 Operating and maintenance instructions

Tractel

Tractel caRol TR150 Operating and maintenance instructions

Cequent FULTON instructions

Cequent

Cequent FULTON instructions

Enthuze ENT4401P owner's manual

Enthuze

Enthuze ENT4401P owner's manual

Champion Power Equipment C50079 owner's manual

Champion Power Equipment

Champion Power Equipment C50079 owner's manual

Andersen Compact Motor 68/72ST product manual

Andersen

Andersen Compact Motor 68/72ST product manual

Ronstan Compact Motor 68/72ST product manual

Ronstan

Ronstan Compact Motor 68/72ST product manual

Strong X009142JA instruction manual

Strong

Strong X009142JA instruction manual

Westin T-MAX ATW4500 Fitting instructions

Westin

Westin T-MAX ATW4500 Fitting instructions

Prowinch PWCD Series user manual

Prowinch

Prowinch PWCD Series user manual

Ramsey Electronics 2000 owner's manual

Ramsey Electronics

Ramsey Electronics 2000 owner's manual

Porter 713220HT installation instructions

Porter

Porter 713220HT installation instructions

TRAC Salt Water Series manual

TRAC

TRAC Salt Water Series manual

Parkside PSZ 250 B2 Operation and safety notes

Parkside

Parkside PSZ 250 B2 Operation and safety notes

haacon TANGO WV 300 operating instructions

haacon

haacon TANGO WV 300 operating instructions

KFI SE45w Owner's Manual and Operating Instructions

KFI

KFI SE45w Owner's Manual and Operating Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.