3. CONNECTIONS AND INSTALLATION
The SET/DM3AL sensor is equipped with a shield-
ed 2-wire cable. The numbered wires 1 and 2 of
the cable are connected to the corresponding con-
nectors (1 = +, 2 = - ) in the control unit. Unnum-
bered wire is connected to the cable shield. Always
check the connections from the installation and
operation manual of the control unit as well.
In figure 3 the connection example 1; a LJB2-78-
83 junction box has been used to connect the ca-
bling to the equipotential bonding.
In figure 3 connection examples 2 and 3; equipo-
tential bonding is not available. The shield is con-
nected to the appropriate connector in the supply
device.
In these kinds of arrangements, it must be
ensured that the electrostatic charges do not
cause a hazard. Make sure in the installation that
the device and cabling are not close to any strong
current or other installations, and that they are not
exposed to any strong stream flows, mechanical
abrasions, or impacts.
The cable may be shortened or extended with a
junction box, if necessary. The sensor may be
installed by hanging it from its cable (upper limit
alarm) or immersed in the liquid to be measured
(lower limit or interface alarms).
The example in figure 3 shows an oil separator
application in which the switch data is received
when the upper electrode is covered in oil i.e. is no
longer immersed in the conductive liquid.
4. OPERATION
This chapter provides a general description of the
operation of the oil alarm in different situations. For
a more detailed description, please refer to the
manual of the control unit in use.