Lakes COASTLINE ONE DOOR QUADRANT ENCLOSURE Maintenance and service guide

Rev 05.12
COASTLINE ONE DOOR QUADRANT ENCLOSURE
Installation / Maintenance Instructions Rev 01.19

IMPORTANT NOTES :
Please Read Carefully & retain these instructions for Future Reference.
1. For ease & safety we advise that two persons assemble this product.
2. Protect shower tray surfaces at all times.
3. Exposed glass corners / edges MUST NOT contact hard surfaces at any time.
4. Check for cables, pipes etc before drilling walls.
5. Ensure all surfaces are dry, clean & free of loose debris / dust.
6. Unpack goods with care (small parts can become lodged in packaging & inadvertently discarded).
Check parts supplied against parts & fittings listed herein. Damaged parts / omissions may be
resolved by calling Lakes Bathrooms Helpline.
7. Whilst precautions are taken in manufacture, care must be taken when handling as rail ends may
have sharp edges.
8. Before commencing, check :
a) shower tray (or base) is level & completely sealed to finished / tiled walls.
b) finished walls are sound & free of cracks, loose tiles / grout.
8. AFTER INSTALLATION, DO NOT ‘WET’ ENCLOSURE FOR 48 HOURS TO ENSURE FULL CURE OF
SILICONE SEALANT.
USE :
General Care & Maintenance.
Provided this product is installed & operated in accordance with these instructions, problems should
not arise. However should maintenance be required it should be carried out by a competent person
with reference to these instructions. Before any work is carried out the root cause of the problem
must be identified. Lakes Bathrooms service engineers are available if necessary to consult / carry out
remedial work. Call Lakes Bathrooms HELPLINE.
Cleaning.
(Every one to two weeks depending on local water {hardness} conditions).
All glass panels in this product have a hydrophobic coating aiding ‘runoff’ of water droplets, reducing
the need for frequent cleaning. For best appearance / product life however, regular cleaning is
recommended.
Use ONLY mild soap / detergent solutions to clean. Rinse with water, squeegee glass panels & wipe
frames dry with a soft cloth. Under no circumstances should abrasive, caustic or scouring products be
used. Cleaning products should have pH value 4 ~ 8. DO NOT use ‘spray & leave’ type cleaning
products. Non compliance with these cleaning instructions may cause decorative finishes to
deteriorate & could adversely affect safe operation of the enclosure.
Limescale ~ should a build up of limescale occur, remove using a 50:50 solution of white vinegar &
water applied with a soft cloth & rinsed / dried thoroughly afterwards.
Daily Care.
To prevent the build up of limescale, do not allow water droplets to dry on glass or frames. After
showering, rinse with water, remove droplets from glass with a squeegee & wipe frame with a soft
cloth.
Customer Service.
Quality Guarantee : Lakes Bathrooms Ltd guarantee Shower Doors & Enclosures against any
manufacturing or material defects for the lifetime of the product. We will resolve defects free of charge
by repairing / replacing parts as we feel necessary. To be ‘free of charge’ service work must be carried
out by Lakes Bathrooms or approved agents.
Not Covered by this Guarantee : Damage or defects that result from improper installation, improper
use, or lack of maintenance (including limescale buildup). Damage or defects that result from repairs /
modifications undertaken by unauthorized persons. This guarantee is in addition to statutory & other
legal rights.
What to do if something goes wrong : Should the product not function correctly on initial use, firstly,
contact the installer to check that unit installation & commissioning are in accordance with these
instructions. Should this not resolve difficulties or should performance decline, consult
‘Troubleshooting’ section to see if simple home maintenance is needed. Alternatively our HELPLINE staff
can assist, or if necessary arrange for a service engineer to visit.
Spares : We maintain extensive spare part stocks. Spares can be ordered / purchased from your retailer
in the first instance. Parts will normally be dispatched within two working days from order placement.
Pro Forma invoices will be sent for cheque payments.

SUPPLIED PARTS :
Doorstop blocks
& Buffers 4 each
Bottom Wheel 2x
Cover Section 2x
4 x 45 pan head self
tapping screw 8x
Wall Plug 8x
Top Wheel 2x
Handle
Kit 1x
Curved Horizontal Profile
(handed pair) complete with
Glazing Blocks
pair each
Cover Caps
Stiffener
(frame corners)
2x
3,5 x 10 pan head self
tapping screw 8x
Wall Profile 2x
wall side
see fig D
Fixed Panel Sub Assy 1x flat : 1x curve
glass
vertical frame
3,5 x 40mm
pan head self
tapping screw
4x
screw location
block 2x
3,5 x 10 pan head self
tapping screws
Top Cap
(wall profile) 2x
Door
Glass
1x
Edge Seal
1x 1989mm
1x 1896mm
Top Cap
(vertical frame) 2x
Magnetic Seal
2x
Glazing Seal 4x

Good quality silicone
sealant & applicator
Spirit Level (with vertical ‘bubble’)
Tools Required
Tape Measure
Pencil Power drill &
8mm masonry bit
Pozidriv Screwdriver
A
3mm HSS drill bit
Lakes Coastline Quadrant is fully reversible, so suitable for fitting to left or right hand trays.
Ensure tray is correctly levelled & that all tray/wall joints are sealed & cured over entire
length of tray sides (See Fig A ) prior to fitting enclosure.
DO NOT SEAL BASE / WALL EDGES UPTO A FITTED ENCLOSURE !
SIZE Adjustment A X Wall Profile Position
(outside)
800 (080) 765—795mm 780mm
900 (090) 865—895mm 880mm
100 (100) 965—995mm 980mm
900800 (090080) 865-895/765-795mm 880 / 780mm
1000800 (100080) 965-995/765-795mm 980 / 780mm
1200800 (120080) 1165-1195/765-795mm 1180 / 780mm
1200900 (120090) 1165-1195/865-895mm 1180 / 880mm
AFFIX WALL PROFILES
X
X outside
of wall profile
Wall profile orientation : Mounting holes to inside (wet area).
Measure, plumb & mark wall profile positions, drill, plug & affix both wall profiles.

B
FRAME SUB ASSEMBLY (glazing blocks / doorstops pre fitted—shown for reference only)
Doorstops :
If necessary, remove / refit as shown
pilot hole
glazing
block/glass
Glazing Block :
If necessary, remove / refit as shown
Glazed Corners. Assemble glazing seals onto glass
end as shown. Check glazing block location around
glass corner before fully tightening corner screws
(2 per corner).

CPLUMB, & AFFIX FRAME
Manipulate & centralise frame
in wall mounts until plumb
(check vertical &horizontal
frame members).
Check that frame is parallel to
tray edges & curve.
With frame in desired position,
from inside enclosure, using
wall profile holes as a guide,
drill dia 3mm pilot holes & affix
frame to wall mounts with 8off
3,5 x 10 self tapping screws.
Carefully orientate cover section, & from inside
enclosure, working from top to bottom, snap fit
cover section onto wall profile.
Fit frame & wall profile top cover caps.
Cover Section
wall side

DOOR ASSEMBLY
DTop Wheel : Assemble with
adjusting screw to underside.
Lightly tighten clamp screw*
& do not fit cover** at this
stage.
Bottom Wheel : Assemble
with push button uppermost.
Fully tighten clamp screw & fit
cover.
**
*
Right hand shown.
(reverse for Left hand)
Assemble handle to glass as
shown (grubscrews to inside).
Ensure plastic washers are
fitted each side beneath
handles.
Tighten grubscrews fully
to retain.

HANG DOORS
E
From outside enclosure, using
buttons, engage bottom wheels in
bottom horizontal profile.
Carefully lift doors into enclosure & engage top wheels into wheel groove.
(If necessary loosen, but do not remove centre screw to permit engagement).
Immediately after all wheels are correctly engaged, fully tighten centre screw to retain door.
Fit internal wheel covers **.
From outside enclosure, using buttons, engage bottom wheels in bottom

FIT EDGE & MAGNETIC SEALS
F
Fit edge seals to leading edges of
fixed panels & trailing edges of doors.
Fit magnetic seals to leading edges of doors as shown.
SEALS MAY BE WETTED TO EASE ASSEMBLY

G
From underside of top wheels, adjust door height until bottom wheels are engaged in
horizontal profile (no wobble). Then adjust door angle plumb with vertical frame profiles &
check door magnets in contact over full door height.
Use of good quality silicone sealant & cleaning / degreasing of all joint areas is recommended.
Apply continuous silicone sealant bead EXTERNALLY ONLY
ADJUST DOORS & SEALING

BASIC TROUBLESHOOTING :
Door motion noisy / Door not running smoothly / Door loose on bottom rail :
Check for edge seals dragging on glass (can cause ‘clicking’ noise).
Check top wheels engaged properly in rails & roll smoothly along rails.
Check door height adjustment ~ raise doors so that spring loaded bottom wheels are in contact with,
& roll smoothly along bottom rail.
Wheels & grooves are factory greased, however over time this may disperse or become contaminated
by dust etc, cleaning of grooves & re application of sanitary silicone based grease will restore & ensure
smooth door motion.
Door rocks in frame on fully opening / closing (on door reaching stops) :
Check door plumb ~ adjust angle until full contact with stops is achieved.
Leakage :
The sealing method described in these instructions relies on a continuous seal being applied
between shower walls & tray before installing the enclosure (see fig A), it ensures a watertight
seal around the perimeter of the enclosure to the shower walls & tray.
In the unlikely event of an enclosure leak, water will be visible on the outside of the enclosure
itself, or around the perimeter joints ONLY. Water / moisture appearing outside this area
(ie at floor level) is normally due to incorrect tray installation.
Lakes Bathrooms Ltd
Alexandra Way
Ashchurch
Tewkesbury
Gloucestershire GL20 8NB
Service England, Scotland, Wales
8.30am—5pm Mon ~ Thurs
8.30am—4.30pm Fri
Tel / HELPLINE : 01684 853870
Fax : 01684 857411
www.lakesbathrooms.co.uk
Email : admin@lakesbathrooms.co.uk
Service : Northern Ireland
Ian A Kernohan
Firtrees
Green Way Industrial Estate
Conlig
Northern Ireland
BT23 7SU
8.30am—5pm Mon ~ Thurs
8.30am—4.30pm Fri
Tel : 02891 270233
Fax : 02891 270597