n®QUICK START GUIDE
TESTING
1. Press and hold until the meter turns on.
2. Tap . Select a Water Source type. Tap to confirm.
3. Tap . Select a disk series (found on disk packaging). Tap
to confirm.
NOTE: Disk Series are limited by Water Source Type selection.
4. Remove a disk from the packaging.
5. Use the syringe (1189) to fill the disk with the water sample.
6. Insert the disk. Cover the disk with the Universal Disk Cover.
Close the lid.
7. Tap to start test. Tap to stop the test. If the test is
cancelled discard the disk.
8. The results will be displayed.
9. Choose an option.
¬Tap to add a tag.
¬Tap the highlighted to save the test results to the
test log if Auto Save is not enabled.
¬Tap the hightlighted to send the results to the
enabled Mobile Bluetooth Printer.
¬Tap the highlighted to send the results to a
Bluetooth enabled device.
¬Tap to return to the Test Screen.
10. Press and hold for 2 seconds to turn the meter off.
DOS & DON’TS
BEFORE FIRST USE
¬Fully charge battery using the Spin Touch
USB cable and adapter plug in AC outlet.
¬Ensure your Spin Touch has latest
firmware
1. Download and install WaterLink®
Connect 2 Application for Windows at
http://softwarecenter.lamotte.com/.
Select WaterLink® Connect 2 Software
for Windows FREE Download.
2. Plug meter into the computer with
the provided USB cable and launch
WaterLink Connect 2 Application from
the Start Menu.
3. A prompt will appear if firmware
updates are available. Select Update.
Testing and data transfer will not
be possible until firmware has been
updated.
NOTE: For water samples over 100 °F (38 °C) subtract
0.3 from pH result or, for the most accurate result,
wait until water sample is below 90 °F (32 °C) to test.
Remove residue daily. Residue will damage the meter
and cause inaccurate results. See Cleaning in manual.
¬Do not touch top or bottom of disk. Handle disk by the
edge.
¬Do not fill disk while in the meter. Fill disk on clean, dry
surface.
¬Fill the disk on a dark surface to more easily see the
sample water.
¬The disk should not contain any large air bubbles. Air
bubbles will result in erroneous results.
¬Always use the disk cover.
¬Only the Universal Disk Cover (Code 1719) can be used
with the WaterLink®Spin Touch®.
¬Empty syringe of old sample before filling with next
sample.
¬Remove filled disk from meter after testing. Do not
travel with filled disks in meter. They may leak.
¬Keep the chamber clean and dry. Gently swab LED
and photodiode lenses located around the hub with
a cotton swab dampened with streak-free window
cleaner. Do not use alcohol. It will leave a thin film over
the lenses when dry.
¬Go to SETTINGS>Other Settings to select hardness and
nitrogen units. Nitrogen results can be reported in ppm
Nitrate-N units or ppm Nitrate units. 1 Nitrate-N unit =
4.4 Nitrate units.
Disk US Patent No. 8,734,734
FCl US Patent No. 8,987,000
FCl EU Patent No. EP2784503 A1
TCl US Patent No. 8,993,337
[email protected] | 410-778-3100 | 800-344-3100 | www.lamotte.com
FILLING
1. Fill the disk using
slow, even pressure.
The sample water
will fill the spaces
between the baffles in a
counterclockwise order.
Each space will fill from
the bottom to the top.
Sample water should be
added until the sample
water in the fourth
chamber fills to the top
of the chamber slightly
past the embossed
fill line. It is OK to fill
slightly past the fill line.
Correct Fill
(Fill line)
2. Do not overfill the
disk. If the disk is
overfilled, sample
water will flow out
of the overflow hole
in the center of the
disk. The disk is not
leaking. Dry the disk
and run the test.
Overfilled
(Dry disk before placing in meter)
3. Do not under fill the
disk. If the disk is under
filled, the reagent
chambers will not fill
entirely and results will
be inaccurate. Underfilled
4. Do not introduce
air bubbles into the
disk. The reagent
chambers will not fill
entirely and results
will be inaccurate.
As soon as a bubble
starts to form, pull
back on the plunger
to draw the bubble
out of the disk. Begin
the filling process
again.
Air
Bubble
5. Wet disks should be
dried thoroughly with a
lint free wipe. The disk
should be handled by
the edges.
6. Disks should be filled and used within 10
minutes. They cannot be filled ahead of time.
For filling and troubleshooting tips go to: www.lamotte.com/spin_support/
BLUETOOTH CONNECTION
The WaterLink®Spin Touch®is capable of connecting to a Bluetooth enabled device, such as a phone or tablet.
The Spin Touch is also compatible with a LaMotte Bluetooth Printer [Code 5-0066]. Other Bluetooth printers
are not supported.
Transferring results over Bluetooth to a mobile device requires that a mobile app is installed on the device and
an active account for the associated software program. For example, with an active WaterLink®Solutions™
account and the WaterLink®Solutions™mobile app on a phone or tablet, results can be transferred from
the meter into the application. Mobile apps for LaMotte software products are available from iTunes (for iOS
devices) and Google Play (for Android devices).
For detailed information read the Spin Touch manual. Go to http://softwarecenter.lamotte.com/ to learn
more about LaMotte software products.
LaMotte, WaterLink, Spin Touch are ® registered trademarks of LaMotte Company
© 2021 LaMotte Company, All Rights Reserved | 3585-QG | 04.27.21

Other manuals for WaterLink Spin Touch DW

5

Other LaMotte Measuring Instrument manuals

LaMotte DC1500 Copper User manual

LaMotte

LaMotte DC1500 Copper User manual

LaMotte SMART Colorimeter User manual

LaMotte

LaMotte SMART Colorimeter User manual

LaMotte WaterLink SpinTouchFF User manual

LaMotte

LaMotte WaterLink SpinTouchFF User manual

LaMotte DC1500 PHOSPHATE User manual

LaMotte

LaMotte DC1500 PHOSPHATE User manual

LaMotte CON 6 PLUS User manual

LaMotte

LaMotte CON 6 PLUS User manual

LaMotte ColorQ TesTabs Pro-9 User manual

LaMotte

LaMotte ColorQ TesTabs Pro-9 User manual

LaMotte Tracer 1749 User manual

LaMotte

LaMotte Tracer 1749 User manual

LaMotte WaterLink Spin Touch User manual

LaMotte

LaMotte WaterLink Spin Touch User manual

LaMotte smart spectro 2 User manual

LaMotte

LaMotte smart spectro 2 User manual

LaMotte Tracer 1766 User manual

LaMotte

LaMotte Tracer 1766 User manual

LaMotte DC1500 CHLORINE User manual

LaMotte

LaMotte DC1500 CHLORINE User manual

LaMotte Tracer 1741 User manual

LaMotte

LaMotte Tracer 1741 User manual

LaMotte PockeTester 1766 User manual

LaMotte

LaMotte PockeTester 1766 User manual

LaMotte Tracer PockeTester User manual

LaMotte

LaMotte Tracer PockeTester User manual

LaMotte WaterLink SpinTouch 3580 User manual

LaMotte

LaMotte WaterLink SpinTouch 3580 User manual

LaMotte DC1500 CHLORINE User manual

LaMotte

LaMotte DC1500 CHLORINE User manual

LaMotte 4140-03 User manual

LaMotte

LaMotte 4140-03 User manual

LaMotte TC-3000 User manual

LaMotte

LaMotte TC-3000 User manual

LaMotte SMART3 User manual

LaMotte

LaMotte SMART3 User manual

LaMotte Tracer 1749 User manual

LaMotte

LaMotte Tracer 1749 User manual

LaMotte DC1500 CHLORINE User manual

LaMotte

LaMotte DC1500 CHLORINE User manual

LaMotte ColorQ DW User manual

LaMotte

LaMotte ColorQ DW User manual

LaMotte pHPLUS DIRECT 2 User manual

LaMotte

LaMotte pHPLUS DIRECT 2 User manual

LaMotte DC1500 SULFATE User manual

LaMotte

LaMotte DC1500 SULFATE User manual

Popular Measuring Instrument manuals by other brands

KIM ELECTRIC KMF000 Series installation manual

KIM ELECTRIC

KIM ELECTRIC KMF000 Series installation manual

MICRO-EPSILON thermoMETER CS Assembly instructions

MICRO-EPSILON

MICRO-EPSILON thermoMETER CS Assembly instructions

Fluke 323 user manual

Fluke

Fluke 323 user manual

Heinz Walz JUNIOR PAM Operator's guide

Heinz Walz

Heinz Walz JUNIOR PAM Operator's guide

Xylem WTW pH/Cond 3320 quick start guide

Xylem

Xylem WTW pH/Cond 3320 quick start guide

Swan Analytical Instruments AMI Codes-II TC Operator's manual

Swan Analytical Instruments

Swan Analytical Instruments AMI Codes-II TC Operator's manual

Mirion Technologies CheckPoint:Laundry RTM750 user manual

Mirion Technologies

Mirion Technologies CheckPoint:Laundry RTM750 user manual

EXFO IQS-5320 user guide

EXFO

EXFO IQS-5320 user guide

HIPOTRONICS KVM-W Series operating instructions

HIPOTRONICS

HIPOTRONICS KVM-W Series operating instructions

KegLand Fill-O-Meter instruction manual

KegLand

KegLand Fill-O-Meter instruction manual

Bosch ISN-GMX-P3S installation guide

Bosch

Bosch ISN-GMX-P3S installation guide

LOVATO ELECTRIC EXP10 31 instruction manual

LOVATO ELECTRIC

LOVATO ELECTRIC EXP10 31 instruction manual

THORLABS PM200 quick reference

THORLABS

THORLABS PM200 quick reference

Rover OMNIA-6 user guide

Rover

Rover OMNIA-6 user guide

Mobeye ThermoGuard CM2200 user manual

Mobeye

Mobeye ThermoGuard CM2200 user manual

Video Clarity ClearView installation guide

Video Clarity

Video Clarity ClearView installation guide

geo-FENNEL FLP 100 user manual

geo-FENNEL

geo-FENNEL FLP 100 user manual

YOKOGAWA YPP6870 manual

YOKOGAWA

YOKOGAWA YPP6870 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.