manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lamptron
  6. •
  7. Controllers
  8. •
  9. Lamptron CM430 User manual

Lamptron CM430 User manual

Other Lamptron Controllers manuals

Lamptron CM512 User manual

Lamptron

Lamptron CM512 User manual

Lamptron CM430 User manual

Lamptron

Lamptron CM430 User manual

Lamptron CM615 User manual

Lamptron

Lamptron CM615 User manual

Lamptron CW611 User manual

Lamptron

Lamptron CW611 User manual

Lamptron FC Touch User manual

Lamptron

Lamptron FC Touch User manual

Lamptron CU423 User manual

Lamptron

Lamptron CU423 User manual

Lamptron FC9 User manual

Lamptron

Lamptron FC9 User manual

Lamptron FC5V3 User manual

Lamptron

Lamptron FC5V3 User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.lamptron.com info@lamptron.com
Lamptron CM430 Instruction Manual
Thank you for choosing LAMPTRON CM430 controller.It
is optimized for air-cooled applications.
Limited Edition:Unque Colors except PWM Control,
Touch , Red-Blue Color and UV Color.
FEATURES:
PWM control
Colorful touch display
Red-Blue Color and UV Color version for your choice
Manual/Auto control
Compatible with PWM fans and stardard fans
Alarm temperature can be adjustable
Differences compared with CM430:
1)Touch Voice can be OFF
2) Adding the function of case temperature measurement
3)Wrong operation reminders
SPECIFICATION:
Dimension 148.5mm * 42.5mm * 63mm
Screen dimension 129mm * 32.5mm(wider screen)
Power output Up to 30 watts per channel
Control channels 4 Channels(1 PWM+3 Stardard Channel)
DC Input +12V(Standard” D” Connector)
DC Ouput 0 V - 12V DC
Compatible PWM and Standard Fans
Color Available UV,R&B
Alarm Alarm temperature can be adjusted
PWM Function PWM control(1st channel)
INSTALLATION:
Installation location:
The CM430 is designed to fit in a 5.25” bay,please use the
included screws to install it within your pc case.(Phillips
screwdriver needed and not included.)
CONNECTIONS:
1. POWER:to 4-Pin Molex Power Connector.
2. PWM: to PWM fans or stardard fans(Note:just 1st channel
offer PWM function)
3. OUT1~OUT3: to standard fans
4. TEMP0~TEMP3: to themal sensors.
OPERATION:
⑴Power On/Off, long press for 3 seconds to turn it off
⑵Start boost mode ⑶Alarm switch ⑷Backlight adjustment button
⑸PWM output ⑹⑺⑻Stardard Fan control output ⑼Increase
⑽Reduce ⑾Automatic mode ⑿Manual mode ⒀Speed, voltage,
Percentage display ⒁Unit display ⒂Speed meter ⒃Functional
area ⒄Temperature ⒅C/F
SETTING:
1. Manual/Auto control
Click to switch between auto and manual control,manual
mode was setuped as default.
2. Backlight brightness setting
Click to control brightness ranging 100% -- 50% -- 0%.
Power-on default is 100%. Backlight automaticly shutdown after 3
minutes in Auto Mode.
3. Alarm On/Off setting
Click for all the Alarm and Touch Voice on/off.
4. Start-boost setting
Click to set on/off Start-boost; the default is Off.
5. Functional area
Click to Select fan work mode between Quiet Mode/Fullpower
mode/ , , , .
for Fullpower which means 100% working ; for Quiet
Mode which means 40%working.
6. Operational settings for each channel
7. Speed, voltage, Percentage display
Click to switch in Speed/voltage/Percentage display.
8. Alarm setting
Long press over 3 seconds to set high or low temperature
for alarming.
www.lamptron.com info@lamptron.com
Lamptron CM430 Instruction Manual(continue)
Speed display:
Touch Speed zone to switch between RPM(speed),%(percentage)
and V(voltage)
1. Speed:RPM(Revolutions Per Minute)
2. Percentage:Power output percentage
3. Voltage:Output voltage
Alarm Temperature setting:
1. Press
2. Long Press “ ⒄Temperature “ display area
3. Choose the fan from , , , selete the channel
you want to set temperature.(the channel connected with
fan,the display will be showed out)
4. Touch “⒀Speed, voltage, Percentage display “area,”HHHH”
and “LLLL” will be switchable in the display area;when
display”HHHH”,means you are setting upper temperature
limit;when display “LLLL” means you are setting lower
temperature limit.(Factory Setting upper temperature limit
50℃/122℉,lower temperature limit 20℃/68℉)
5. touch , to set the temperature.
One short touch means 0.1℃or 1°F;Long Touch ranging
1℃or 10°F.
6. Touch to save the setting,Done!.
Restore factory settings:
In Manul Mode,long touch ,system will restore to
factory settings.
Factory settings data:
Alarm and Touch Voice ON
Start-boost OFF
Temperature display ℃
Speed RPM.
The percentage of fan speed 40%.
Upper temperature limit 50℃/122℉
Lower temperature limit 20℃/68℉.
Start-boost setting:
1. On :Working voltage range DC7V~~DC12V.
2. Off :Working voltage range DC0V~~DC12V.
Automatic operation mode:
1. Press into Auto mode.
System will work according to specified upper and lower
temperature limits, fans will run automaticlly according to
system detected temperatures.
2. Fans will run in 100% when temperature≥ upper temperature
limit,
3. Start-boost On ,fans will run in 40% when temperature
≤lower temperature limit
4. Start-boost Off , fans will be off when temperature ≤lower
temperature limit
⒃Functional area will circulate between operating channels
Fullpower mode:
Press to ,Fullpower mode works,fans run at 100%
percentage(full speed)
⒃Functional area will circulate between operating
channels
Quiet Mode:
Press to ,Silent mode works,fans run at 40%
percentage(Quiet Mode)
⒃Functional area will circulate between operating
channels
Accessories:
1 CM430
3pcs 3-PIN fan extension cables
1pcs 4-PIN PWM fan extension cable
4pcs thermal sensor cables
4pcs Screws
1 Installation Guide
We hope you enjoy your CM430 and it serves your
projects well.if you think any aspect of the CM430 can be
improved or if you are willing to share your creative ideas with
us, you are more than welcomed to contact us through our
email (info@lamptron.com).We are always happy to hear from
you !