and represent the output of that channel, value, units,
You can choose speed (RPM), voltage (Vol), or flow units (LPH GPM),
the default is speed (RPM).
Tip: Only in the channel used by the electronic flowmeter can you choose
the flow unit, fan and pump modes can only use speed (RPM) or voltage
(Vol) units.
Connect the power supply “P”, the controller goes into normal operation,
and the screen will display “ ” logo; press Key or Key ,
Or rotate ; enter the main interface explained below:
Show channel 1~6 icon, position for the selected
channel,You can use the knob clockwise or counter-clockwise rotation
to rotate through the channels. Icons . Each channel can
choose one in three operational modes. The default is fan mode when
you first start your CW611:
Lamptron CW611 instruction manual
SPECIFICATIONS:
Thank you for choosing the LAMPTRON CW611
controller, this controller is designed & optimized for
both air-cooled and water-cooled applications.
For computer use only.
Large screen, narrow border design, clear and pleasing white on
black, high-brightness backlight.
Use of a knob and a secondary button will allow you to be able to
use all of the functions easily.
Each channel can be used in three optional modes of fan, pump and
flow meter. Every channel is identified with an intuitive icon for each
mode.
Each channel can be individually set to manual mode (M) or
automatic mode (A). Set the target temperature of the channel in
automatic mode and you can specify the lowest output value and the
highest output value per channel. If the actual temperature does not
reach the target temperature, the output remains in the minimum set
value, when the actual temperature exceeds the target temperature,
the output begins to increase. Automatic control supports fans
equipped with or without tachometers.
Each of the 6 channels has a maximum output of 36 watts, which you
can easily cycle using the knob.
When a channel is placed in fan or water pump mode, you can set
the channel to show voltage or speed units.
Backlight brightness options of 20%, 50%, 80%, 100%, and OFF, so
you can choose what suits you best.
Each individual channel can turn on or off the alarm based on Celsius
or Fahrenheit.
Commonly used features and advanced functions are separated,
press the knob for a short period to enter the frequently used
functions of the current channel settings, or press it for a longer
period to enter the advanced features of the current channel.
Press the auxiliary key to navigate through the options while in that
mode, one finished, press the knob for a shot period to return to the
main interface.
OPERATION:
Dimension
148.5mm * 42.5mm * 63mm
LCD Dimension
118mm * 31mm(wide screen)
Power Output
Up to 36 watts per channel
Control Channel
6 Channels
Color Available
Black Anodized/Silver
DC Input + 12V(Standard “D” Connector)
DC Output 0V - 12V DC
Connectors 6pcs 3pin connectors
INSTALLATION:
The CW611 is designed to fit in a 5.25” bay, please use the included
screws to install it within your pc case. (Phillips screwdriver required
and not included)
Installation location:
Press and hold the knob to enter the settings of the current channel.
To enter the commonly used settings, press the knob for a short period.
To enter the more advanced settings, press for a longer period.
Rotate the knob to change the parameters accordingly.
Press the knob for a short period to exit to the main screen.
Auxiliary keys used to confirm setting changes after selecting them
within the menu (access explained in the previous point). In addition, in
the main interface, press the auxiliary button can switch the backlight
brightness, backlight will be 100% > 80% > 50% > 20% > turn off the
backlight > 20% > 50% > 80% > 100% of the sequence cycle.
CONNECTIONS:
Instructions:
1. P: Standard Molex. Connect to your power supply.
Tip: Be sure to use at least 18AWG wiring specifications.
2. P1 ~ P6: Channels 1 to 6 output interface (compatible fan, water
pump, electronic flow meter), the six interfaces are standard with
KF2510 3pin interfaces.
Tip: You can also use a KF2510 4pin connector.
3. TEMP1 ~ TEMP6: are respectively connected to the P1~P6
secondary connectors corresponding to the sensors.
Tip: Automatic control of each output channel is carried out according
to the temperature reported by the temp sensors.
1
1
2
12
2
34 5 6 7 8
Alarm icon, The default is off (which will show , when turned on,
it´ll show . Each channel can be individually turned on or off (in terms
of the Alarm).
CW611
1
2
Fan Water Pump Electronic Flow Meter
34 85 7
6
9
10 11 12 13 14 15
2
1
CW611
1
2
3
1
34567
9
Shows current operational mode.
10 10
11 11
13
14
15
The temperature values of the currently selected channel.
Temperature unit, the default is Celsius ℃but can be changed to
Fahrenheit ℃. Each channel can be individually defined.
Current backlight level. Instructions on how to change this are written
earlier in this manual.
F

Other Lamptron Controllers manuals

Lamptron CU423 User manual

Lamptron

Lamptron CU423 User manual

Lamptron CM512 User manual

Lamptron

Lamptron CM512 User manual

Lamptron CM430 User manual

Lamptron

Lamptron CM430 User manual

Lamptron FC9 User manual

Lamptron

Lamptron FC9 User manual

Lamptron CM430 User manual

Lamptron

Lamptron CM430 User manual

Lamptron FC Touch User manual

Lamptron

Lamptron FC Touch User manual

Lamptron CM615 User manual

Lamptron

Lamptron CM615 User manual

Lamptron FC5V3 User manual

Lamptron

Lamptron FC5V3 User manual

Popular Controllers manuals by other brands

Linear LTM4636 manual

Linear

Linear LTM4636 manual

DeZurik G-SERIES manual

DeZurik

DeZurik G-SERIES manual

Flycolor Raptor S-Tower 20A F4 FC user manual

Flycolor

Flycolor Raptor S-Tower 20A F4 FC user manual

Newport ESP302 Startup manual

Newport

Newport ESP302 Startup manual

AviteQ Vibtronic SC-2 Series operating manual

AviteQ

AviteQ Vibtronic SC-2 Series operating manual

Enttec OCTO MK2 user manual

Enttec

Enttec OCTO MK2 user manual

Roth BW/H Komfort HE Manual for the specialised craftsman

Roth

Roth BW/H Komfort HE Manual for the specialised craftsman

CGS MERLIN GDPX+ Installation operation & maintenance

CGS

CGS MERLIN GDPX+ Installation operation & maintenance

PACSystems RX3i Important product information

PACSystems

PACSystems RX3i Important product information

Faller 180725 instruction manual

Faller

Faller 180725 instruction manual

Enttec DMXEtherGate Mk2 manual

Enttec

Enttec DMXEtherGate Mk2 manual

Edgewater Networks EdgeMarc 4800 Hardware installation guide

Edgewater Networks

Edgewater Networks EdgeMarc 4800 Hardware installation guide

Maxim MAX3421E Programming guide

Maxim

Maxim MAX3421E Programming guide

THORLABS LCC25 operating manual

THORLABS

THORLABS LCC25 operating manual

EUROSTER 11WBZ Installation and operation manual

EUROSTER

EUROSTER 11WBZ Installation and operation manual

BENDIX EC-30 ABS-ATC CONTROLLER Troubleshooting

BENDIX

BENDIX EC-30 ABS-ATC CONTROLLER Troubleshooting

Danfoss Optyma Plus user guide

Danfoss

Danfoss Optyma Plus user guide

DOGA HDC-30i instruction manual

DOGA

DOGA HDC-30i instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.