Lamptron CU423 User manual

www.lamptron.com info@lamptron.com
Lamptron CU423 Instruction Manual
Thank you for choosing LAMPTRON CU423
controller. This controller is compatible with air
cooling and water cooling control.
FEATURES:
Classic Clock Dial design
40W per Channel,4 channels
Voltage,Speed and Temperature display
Manual/Auto Control Mode available
High quality sleeved wires
We recommend that you read the following detailed description
of the installation manual before using the CU423
SPECIFICATION:
Dimension 148.5mm * 42.5mm * 65mm
Power output Up to 40 watts per channel
Control channels 4 Channels
DC Input +12V(standard power interface + 5557-2 D
shape * 4 p r)
DC Ouput 0 V - 12V DC
Compatible 2510 male head 3 p socket
INSTALLATION:
Installation location:
The CU423 is designed to fit in a 5.25” bay,please use the
included screws to install it within your pc case.(Phillips scre
wdriver needed and not included.) According to your actual si
tuation, please reserve a good connection and linear space.
CONNECTIONS:
1. PWR_IN1 and PWR_IN2: input power supply
Warning: Please be sure connecting PWR-IN1 and PWR-IN2 at
the same time,then the CU423 can work normally!!!
2. OUT1 ~ OUT4: channel 1 ~ 4 output, it is a standard 3 pin
KF2510 interface.(you can also connect KF2510 4 pin
connector)
3. TEMP1 ~ TEMP4: connect to the temperature sense
4. J2: start boost on/off.
OPERATION:
①②③④ndicates the channel 1 to 4, ⑤reduce,⑥increase,
⑦Speed indicator light,⑧ temperature indicator light,⑨Voltage
indicator light
SETTING:
Power on over 2 seconds to enter the display mode.At same
time,each channel can be setup.
Automatic mode is ruuning at least 4.5 V - 12 V
In Auto Mode,the indicator lights are all lighted up(Voltage,
Speed,Temperature).
1, CU423 can be ruuning in Manul/Auto Mode.In Auto Mode,user
can not make any changes.
2, the left side of button for reducing, the right side of the button for
increasing;
Short push each button means switching from Voltage,Speed
and Temperature
Long Push each button over 3 second means switching
between Manul/Auto Mode.
3, CU423 start boost function ON
CU423 start boost function OFF
Setup Manual/Auto Mode:
CU423 setup as manual mode originally.
Long press the button for 3 seconds to switch between
Manul/Auto mode
Once choosed Auto Mode,3 indicators LEDs(Voltage,Speed
and Temperature) all lighted up to show Auto mode is ON.
Once choosed Manual Mode, 3 indicators
LEDs(Voltage,Speed and Temperature) all lighted up to show Auto
mode is OFF.
Manual mode:
CU423 defaults as Speed indicator is ON
Short press the button to switch to the voltage indicator ON,
press button on the right side is inceasing,press button on the left
side is reducing.
CU423 have memory function.Once power off,CU423 can running
back to last time users’ setup.
Automatic mode:
CU423 automatic modemeans the target temperature is 45 ,℃
the minimum voltage is 4.5V,the maximum voltage of 12V.Once the
temperature is above 60 .CU423℃will works in full power
(Warning: automatic mode needs to connect the corresponding
channel of thermal sensors.)
Alarm function:
When the voltage reaches 7 v and above, and no speed at the
same time, then alarming and speed indicator flashing.
When the temperature reached 85 ℃and above, then alarming and
temperature indicator flashing
We hope you enjoy Lamptron CU423 and it
serves your projects well.if you think any aspect of
the CU423 can be improved or if you are willing to
share your creative ideas with us, you are more than
welcomed to contact us through our email
([email protected]).We are always happy to hear
from you !

Other Lamptron Controllers manuals

Lamptron CM430 User manual

Lamptron

Lamptron CM430 User manual

Lamptron CM512 User manual

Lamptron

Lamptron CM512 User manual

Lamptron FC9 User manual

Lamptron

Lamptron FC9 User manual

Lamptron CM615 User manual

Lamptron

Lamptron CM615 User manual

Lamptron FC5V3 User manual

Lamptron

Lamptron FC5V3 User manual

Lamptron CM430 User manual

Lamptron

Lamptron CM430 User manual

Lamptron FC Touch User manual

Lamptron

Lamptron FC Touch User manual

Lamptron CW611 User manual

Lamptron

Lamptron CW611 User manual

Popular Controllers manuals by other brands

Mitsubishi FX2N-4AD-PT user guide

Mitsubishi

Mitsubishi FX2N-4AD-PT user guide

Warmup butech 8GM operating manual

Warmup

Warmup butech 8GM operating manual

MAR-IN Controls SG 6100 Technical manual

MAR-IN Controls

MAR-IN Controls SG 6100 Technical manual

Seada SolarWall Pro Series quick start guide

Seada

Seada SolarWall Pro Series quick start guide

TECH SINUM PS-10 230 manual

TECH

TECH SINUM PS-10 230 manual

Aiphone LEM-1DL/C manual

Aiphone

Aiphone LEM-1DL/C manual

Emerson MultiFlex RTU Installation and operation manual

Emerson

Emerson MultiFlex RTU Installation and operation manual

Opera 6000 series Operation manual

Opera

Opera 6000 series Operation manual

GOK NDR 0515 Assembly and operating manual

GOK

GOK NDR 0515 Assembly and operating manual

Reflex Servitec S operating manual

Reflex

Reflex Servitec S operating manual

Neptune RM-12P manual

Neptune

Neptune RM-12P manual

T-Motor fixed wing Series instructions

T-Motor

T-Motor fixed wing Series instructions

Watts Vision Wired WFC-03 6Z HC 24 Quick installation guide

Watts

Watts Vision Wired WFC-03 6Z HC 24 Quick installation guide

ADTEK CS2-RL Operation manual

ADTEK

ADTEK CS2-RL Operation manual

YASKAWA A1000 Series manual

YASKAWA

YASKAWA A1000 Series manual

National Instruments PXI-8150B Note to Users

National Instruments

National Instruments PXI-8150B Note to Users

Sanhua MQ-A11 Series instructions

Sanhua

Sanhua MQ-A11 Series instructions

ABB COMMANDER 310 installation guide

ABB

ABB COMMANDER 310 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.