Lanner LEC-6032C User manual

Industrial Communication Platforms
LEC-6032C
User Manual
Version: 1.8
Date of Release:2022-10-06

LEC-6032C User Manual
2
This manual describes the overview of the various functionalities of this product, and the
information you need to get it ready for operation. It is intended for those who are:
-responsible for installing, administering and troubleshooting this system or Information
Technology professionals.
-assumed to be qualified in the servicing of computer equipment, such as professional system
integrators, or service personnel and technicians.
The latest version of this document can be found on Lanner’s official website, available either
through the product page or through the Lanner Download Center page with a login account and
password.
The icons are used in the manual to serve as an indication of interest topics or important messages.
Icon
Usage
This mark indicates that there is something you should pay
special attention to while using the product.
This mark indicates that there is a caution or warning and it is
something that could damage your property or product.
To obtain additional documentation resources and software updates for your system, please visit
the Lanner Download Center. As certain categories of documents are only available to users who
are logged in, please be registered for a Lanner Account at http://www.lannerinc.com/ to access
published documents and downloadable resources.
In addition to contacting your distributor or sales representative, you could submit a request at our
Lanner Technical Support and fill in a support ticket to our technical support department.
Your feedback is valuable to us, as it will help us continue to provide you with more accurate and
relevant documentation. To provide any feedback, comments or to report an error, please email
[email protected]m. Thank you for your time.
Note or Information
Warning or Important

LEC-6032C User Manual
3
Taiwan Corporate Headquarters
Lanner Electronics Inc.
7F, No.173, Sec.2, Datong Rd.
Xizhi District, New Taipei City 22184,
Taiwan
立端科技股份有限公司
221 新北市汐止區
大同路二段 173 號7樓
T: +886-2-8692-6060
F: +886-2-8692-6101
China
Beijing L&S Lancom Platform Tech. Co.,
Ltd.
Guodong LOFT 9 Layer No. 9 Huinan Road,
Huilongguan Town, Changping District,
Beijing
102208 China
T: +86 010-82795600
F: +86 010-62963250
E: service@ls-china.com.cn
USA
Lanner Electronics Inc.
47790 Westinghouse Drive
Fremont, CA 94539
T: +1-855-852-6637
F: +1-510-979-0689
E: sales_us@lannerinc.com
Canada
Lanner Electronics Canada Ltd
3160A Orlando Drive
Mississauga, ON
L4V 1R5 Canada
T: +1 877-813-2132
F: +1 905-362-2369
E: sales_ca@lannerinc.com
Europe
Lanner Europe B.V.
Wilhelmina van Pruisenweg 104
2595 AN The Hague
The Netherlands
T: +31 70 701 3256
E: sales_eu@lannerinc.com

LEC-6032C User Manual
4
This document is copyrighted © 2022 by Lanner Electronics Inc. All rights are reserved. The original
manufacturer reserves the right to make improvements to the products described in this manual at any time
without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by
any means without the prior written permission of the original manufacturer. Information provided in this
manual is intended to be accurate and reliable. However, the original manufacturer assumes no responsibility
for its use, nor for any infringements upon the rights of third parties that may result from such use.
Intel® and Intel® Atom® are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other
countries. Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp. All other product
names or trademarks are properties of their respective owners.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note
1. An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby
radio and television reception. It is essential that only the supplied power cord be used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
Important
1. Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
2. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.

LEC-6032C User Manual
5
Follow these guidelines to ensure general safety:
Keep the chassis area clear and dust-free during and after installation.
Do not wear loose clothing or jewelry that could get caught in the chassis. Fasten your tie or scarf and roll
up your sleeves.
Wear safety glasses if you are working under any conditions that might be hazardous to your eyes.
Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
Disconnect all power by turning off the power and unplugging the power cord before installing or
removing a chassis or working near power supplies.
Do not work alone if potentially hazardous conditions exist.
Never assume that power is disconnected from a circuit; always check the circuit.
Suivez ces consignes pour assurer la sécuritégénérale :
Laissez la zone du châssis propre et sans poussière pendant et après l’installation.
Ne portez pas de vêtements amples ou de bijoux qui pourraient être pris dans le châssis. Attachez votre
cravate ou écharpe et remontez vos manches.
Portez des lunettes de sécurité pour protéger vos yeux.
N’effectuez aucune action qui pourrait créer un danger pour d’autres ou rendre l’équipement dangereux.
Coupez complètement l’alimentation en éteignant l’alimentation et en débranchant le cordon
d’alimentation avant d’installer ou de retirer un châssis ou de travailler à proximité de sources
d’alimentation.
Ne travaillez pas seul si des conditions dangereuses sont présentes.
Ne considérez jamais que l’alimentation est coupée d’un circuit, vérifiez toujours le circuit. Cet appareil
génère, utilise et émet une énergie radiofréquence et, s’il n’est pas installé et utilisé conformément aux
instructions des fournisseurs de composants sans fil, il risque de provoquer des interférences dans les
communications radio.
There is risk of Explosion if Battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Installation only by a skilled person who knows all Installation and Device Specifications which are to be
applied.
Do not carry the handle of power supplies when moving to another place.
Please conform to your local laws and regulations regarding safe disposal of lithium BATTERY.
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in
an explosion.
Leaving a battery in an extremely high temperature surrounding environment can result in an explosion or
the leakage of flammable liquid or gas.
A battery subjected to extremely low air pressure that may result in an explosion or the leakage of
flammable liquid or gas.
Risque d’explosion si la pile est remplacée par une autre d’un mauvais type.
Jetez les piles usagées conformément aux instructions.
L’installation doit être effectuée par un électricien formé ou une personne formée à l’électricité connaissant
toutes les spécifications d’installation et d’appareil du produit.
Ne transportez pas l’unité en la tenant par le câble d’alimentation lorsque vous déplacez l’appareil.
Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment to
acceptable operating temperatures without adequate circulation. Be sure that the room in which you
choose to operate your system has adequate air circulation.
Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An

LEC-6032C User Manual
6
open chassis permits air leaks, which may interrupt and redirect the flow of cooling air from internal
components.
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs
when electronic components are improperly handled and can result in complete or intermittent failures.
Be sure to follow ESD-prevention procedures when removing and replacing components to avoid these
problems.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. If no wrist strap is available,
ground yourself by touching the metal part of the chassis.
Periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms
(Mohms).
L’équipement électrique génère de la chaleur. La température ambiante peut ne pas être adéquate pour
refroidir l’équipement à une température de fonctionnement acceptable sans circulation adaptée. Vérifiez
que votre site propose une circulation d’air adéquate.
Vérifiez que le couvercle du châssis est bien fixé. La conception du châssis permet à l’air de refroidissement
de bien circuler. Un châssis ouvert laisse l’air s’échapper, ce qui peut interrompre et rediriger le flux d’air
frais destiné aux composants internes.
Les décharges électrostatiques (ESD) peuvent endommager l’équipement et gêner les circuits électriques.
Des dégâts d’ESD surviennent lorsque des composants électroniques sont mal manipulés et peuvent causer
des pannes totales ou intermittentes. Suivez les procédures de prévention d’ESD lors du retrait et du
remplacement de composants.
Portez un bracelet anti-ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est
disponible, reliez votre corps à la terre en touchant la partie métallique du châssis.
Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et 10
mégohms (Mohms).
Mounting Installation Precaution
Do not install and/or operate this unit in any place that flammable objects are stored or used in.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore, consideration should be given to installing
the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by
the manufacturer.
Installation of the equipment (especially in a rack) should consider the ventilation of the system’s intake
(for taking chilled air) and exhaust (for emitting hot air) openings so that the amount of airflow required
for safe operation of the equipment is not compromised.
To avoid a hazardous load condition, be sure the mechanical loading is even when mounting.
Consideration should be given to the connection of the equipment to the supply circuit and the effect that
overloading of the circuits might have on over-current protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable earthing should be maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g., use of power strips).
Installation & Operation:
This equipment must be grounded. The power cord for product should be connected to a socket-outlet
with earthing connection.
Cet équipement doit être mis à la terre. La fiche d'alimentation doit être connectée à une prise de terre
correctement câblée
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National
Electrical Code and NFPA 75.
Peut être installé dans des salles de matériel de traitement de l'information conformément à l'article 645
du National Electrical Code et à la NFPA 75.
The machine can only be used in a restricted access location and must be installed by a skilled person.
Les matériels sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT.

LEC-6032C User Manual
7
Warning
Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired
earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible
metal parts.
“Product shall be used with Class 1 laser device modules.”
Avertissement
Équipement de classe I. Ce matériel doit être relié à la terre. La fiche d’alimentation doit être raccordée à une
prise de terre correctement câblée. Une prise de courant mal câblée pourrait induire des tensions
dangereuses sur des parties métalliques accessibles.
“Le produit doit être utilisé avec des modules de dispositifs laser de classe 1.”
Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding)
is very important to protect the equipment against the harmful effects of external noise and to reduce the risk
of electrocution in the event of a lightning strike. To uninstall the equipment, disconnect the ground wire
after turning off the power. A ground wire is required and the part connecting the conductor must be greater
than 4 mm2 or 10 AWG.
Avant d’allumer l’appareil, reliez le câble de mise à la terre de l’équipement à la terre.
Une bonne mise à la terre (connexion à la terre) est très importante pour protéger l’équipement contre les
effets néfastes du bruit externe et réduire les risques d’électrocution en cas de foudre.
Pour désinstaller l’équipement, débranchez le câble de mise à la terre après avoir éteint l’appareil.
Un câble de mise à la terre est requis et la zone reliant les sections du conducteur doit faire plus de 4 mm2
ou 10 AWG.
Loosen the screw of the earthing point.
Connect the grounding cable to the ground.
The protection device for the power source must provide 30 A current.
This protection device must be connected to the power source before power.
The cable hould 16 AWG
Desserrez la vis du terminal de mise à la terre.
Branchez le câble de mise à la terre à la terre.
L’appareil de protection pour la source d’alimentation doit fournir 30 A de
courant.
Cet appareil de protection doit être branché à la source d’alimentation avant
l’alimentation.
Le câble doit 16 AWG

LEC-6032C User Manual
8
Table of Contents
Ordering Information.................................................................................................. 9
Specifications ............................................................................................................ 10
Mechanical Drawing..................................................................................................11
Block Diagram.......................................................................................................... 12
Front I/Os.................................................................................................................. 13
Side I/Os.................................................................................................................... 14
Rear I/Os ................................................................................................................... 14
Jumpers & Connectors Locations on the Motherboard ............................................ 15
Jumper Settings & Connector Pinout ...................................................................... 18
Installing SO-DIMM Memory.................................................................................. 26
Installing a Disk Drive .............................................................................................. 27
Mounting LEC-6032 by DIN Rail ............................................................................ 29
Main .................................................................................................................. 32
Advanced .......................................................................................................... 33
Chipset .............................................................................................................. 55
Security ............................................................................................................. 59
Boot................................................................................................................... 60
Save & Exit....................................................................................................... 62

LEC-6032C User Manual
9
Thank you for choosing LEC-6032 series. This industrial embedded Box PC is designed for
networking capability for industrial environments. LEC-6032 is built with Intel Atom E3845 CPU
inside for low processing power consumption. The system provides 5 LAN ports for network
connections and 2 additional SFP ports for model type-C. To fit in harsh industrial environment,
LEC-6032 can be mounted by DIN Rail and supports wide temperature operations. LEC-6032 is
definitely the compact and robust embedded Box PC for industrial communications.
Product Features:
⚫Intel® Atom E3845 CPU
⚫1 x 4 GB DDR3L SDRAM SO-DIMM socket
⚫USB: 1 x USB 2.0 Type-A port and 1 x USB 3.0 Type-A port
⚫Serial: 1 x RS-232 pin header. The port is enabled via cable connection.
⚫LAN port configuration
LEC-6032 B/D: 5 x RJ-45 10/100/1000 Mbps ports
LEC-6032 C: 5 x RJ-45 10/100/1000 Mbps ports and 2 x SFP GbE ports
LEC-6032 F: 3 x RJ-45 10/100/1000 Mbps ports and 4 x SFP GbE ports
⚫LAN Bypass (Lanner’s Generation 3 bypass)
⚫Display: 1 x VGA pin header
⚫Storage: 1 x SATA 2.5” HDD/SSD kit
⚫Standards & Certifications: RoHS, CE, FCC
⚫Wide temperature : -40 to 75℃
Ordering Information
LEC-6032C
Wide Temperature DIN rail Fanless Box PC with Intel Atom E3845 processor, 5
x GbE RJ45 with 1 pair Gen 3 bypass, 2 x GbE SFP, 1 x USB 3.0 host, 1 x USB
2.0 host, 1 x DB9 RS232

LEC-6032C User Manual
10
Processor
Intel® Atom™ Processor E3845 (4 Cores, 1.91 GHz)
Memory
1x 204-pin SO-DIMM DDR3L, 1333 MHz, up to 8GB
BIOS
AMI SPI Flash BIOS
Serial Port
1x DB9 RS-232 w/ 1.5 KV ESD Protection
USB Port
1x USB 3.0 Type-A port
1x USB 2.0 Type-A port
Graphic
Intel® HD Graphics,
1x VGA internal pin-header
Storage
1x SATA 2.5” HDD/SSD kit
Network
Controller
Intel® i210-IT
Ports
5x RJ45 10/100/1000Mbps Ports w/ 1 pair Gen 3 bypass,
2x GbE SFP Ports
Protection
1.5KV built-in
LEDS
HDD: Blinking indicates hard disk activities, whereas off indicates there is no
hard disk present or data access activities.
RUN: A programmable dual green/red LEDs which can be used for
indicating system status.
PWR: Green indicates power-on, whereas off indicates power-off status.
SFP(only LEC-6032 C/F): Blinking indicates active, and green indicates link
for fiber status.
LAN: Active in blinking yellow LED, and speed in green (100Mbps) / yellow
(1Gbps).
Mechanical
Dimensions
78 x 146 x 127mm
Housing
Aluminum
Mounting
DIN Rail
Power
12~36 Vdc, 6032E:24 Vdc, Phoenix contact 6-pin connector w/ lock
Watchdog
Timer
Watchdog Timer 256 Level Time Interval System Reset, Software
Programmable
Environment
Operating Temperature
-40~75℃
Storage Temperature
-40~85℃
Humidity
5% to 95% (non-condensing)
Driver Support
Microsoft Windows
Linux
Standards &
Regulations
Green
RoHS
EMC
CE, FCC Class A

LEC-6032C User Manual
11
Mechanical Drawing
Unit: mm

LEC-6032C User Manual
12
Block Diagram

LEC-6032C User Manual
13
Front I/Os
F1 PWR/RUN/HDD LED
1 x PWR/RUN/HDD LED set for power, device and
storage activity status
F2 SFP LED
Blinking indicates active, and green indicates link for
fiber status
F3 LAN
5 x 10/100/1000 mbps RJ-45 LAN ports
F4 SFP
2 x SFP GbE ports
F5 USB 2.0
1 x USB2.0 Type-A port
F6 USB 3.0
1 x USB3.0 Type-A port
F7 DB9 COM
1 x DB9 COM port with RS-232 (enabled by connecting
the required cable to the internal pin header)
F1
F2
F4
F3
F7
F5
F6
F4

LEC-6032C User Manual
14
Side I/Os
S1 Power Input
12 - 36Vdc power input via 6-pin Phoenix Contact
connector
Rear I/Os
The bracket on the rear is designed for DIN Rail mounting purpose.
S1

LEC-6032C User Manual
15
Jumpers & Connectors Locations on the Motherboard
J3
J2
USB1
LAN1/2
USB2
LPC1
CON1
SPIROM
JP1
J4
COM1
VGA1
RST2
J5
MCU1

LEC-6032C User Manual
16
Jumpers & Connectors Locations for I/O Card
CN1
LANB1/2/3
SFP1/2
J1
P12V1

LEC-6032C User Manual
17
The Motherboard
Label
Description
LAN1/2
2 x RJ-45 LAN ports
USB1
1 x USB3.0 Type-A port
USB2
1 x USB2.0 Type-A port
COM1
RS-232 internal pin header
VGA1
Internal VGA pin header
RST2
Jumper setting for hardware/software reset
JP1
Board-to-board power connector
SPIROM1
For debug purpose
J4
DIMM
J2
SATA 7-pin signal connector
CON1
SATA 4-pin power connector
J3
2x40pin board-to-board connector
LPC1
For debug purpose
MCU1
LPC1114 burn connector
J5
Clear CMOS
I/O Card
Label
Description
CN1
6-pin power input
LANB1/2/3
3 x GbE LAN ports
P12V1
Board-to-board power connector
J1
Board-to-board connector
SFP1/2
2 x SFP LAN ports

LEC-6032C User Manual
18
Jumper Settings & Connector Pinout (Motherboard)
PWR1: Power On/Off
Jumper
Description
1-2
Power ON/OFF system
NC (Default)
Normal
CLR1:Clear CMOS
Jumper
Description
1-2
Clear CMOS RAM
NC (Default)
Normal
J1: AT mode select
Jumper
Description
1-2
AT mode
NC (Default)
Normal
RST2: Hardware/Software select
Jumper
Description
1-2
Software reset
2-3 (Default)
Hardware reset
J5: LPC1114 Burn Select
Jumper
Description
2-3
Burn mode
NC (Default)
Normal

LEC-6032C User Manual
19
Connector Pin Assignment
VGA1: VGA pin header
Pin
Description
1
VGA_R
2
GND
3
VGA_G
4
GND
5
VGA_B
6
GND
7
VGA_HSYNC
8
GND
9
VGA_VSYNC
10
Ground
11
DD_DATA
12
DD_CLK
LPC1: LPC pin header (For debug purpose)
Pin No.
Description
Pin No.
Description
1
LPC_CLK_1
2
LPC_AD1
3
PLTRST_P80_N
4
LPC_AD0
5
LPC_FRAME_N
6
P3V3
7
LPC_AD3
8
GND
9
LPC_AD2
10
GND

LEC-6032C User Manual
20
COM1: serial COM pin header with RS-232 signal
Pin No.
Description
Pin No.
Description
1
NC
2
NC
3
COM1_RXD
4
NC
5
COM1_TXD
6
NC
7
NC
8
NC
9
COM1_GND
SPIROM1: SPI ROM Connector (For debug purpose)
Pin
Description
Pin
Description
1
SPI_HD1_N
2
PCH_SPI_CS1_N
3
PCH_SPI_CS0_N
4
V_3P3_SPI_R
5
PCH_SPI_MISO
6
SPI_HD0_N
7
NC
8
PCH_SPI_CLK
9
GND
10
PCH_SPI_MOSI
MCU1: LPC1114 Burn Connector
Pin
Description
Pin
Description
1
NC
2
NC
3
PIO1_6_RXD
4
PIO1_5_RTS_N
5
PIO1_7_TXD
6
PIO0_7_CTS_N
7
NC
8
NC
9
GND
10
P3V3SB
Table of contents
Other Lanner Desktop manuals

Lanner
Lanner FW-7526 User manual

Lanner
Lanner LVC-5550S User manual

Lanner
Lanner LEC-2055 User manual

Lanner
Lanner LEC-6040 User manual

Lanner
Lanner LEC-2250 User manual

Lanner
Lanner LEC-2530 User manual

Lanner
Lanner LEC-2290H User manual

Lanner
Lanner NVA-3000 Series User manual

Lanner
Lanner NCA-1020 Series User manual

Lanner
Lanner LEC-6021A User manual