Lanner NCA-4030 User manual

1
NCA-4030
User Manual
Version: 1.0
Date of Release: 2022-10-21
Network Appliance Platforms

NCA-4030 User Manual
2
This manual describes the overview of the various functionalities of this product, and the information you need
to get it ready for operation. It is intended for those who are:
-responsible for installing, administering and troubleshooting this system or Information Technology
professionals.
-assumed to be qualified in the servicing of computer equipment, such as professional system integrators,
or service personnel and technicians.
The latest version of this document can be found on Lanner’s official website, available either through the
product page or through the Lanner Download Center page with a login account and password.
The icons are used in the manual to serve as an indication of interest topics or important messages. Below is a
description of these icons:
Icon
Usage
This mark indicates that there is something you should pay special
attention to while using the product.
This mark indicates that there is a caution or warning and it is
something that could damage your property or product.
To obtain additional documentation resources and software updates for your system, please visit the Lanner
Download Center. As certain categories of documents are only available to users who are logged in, please be
registered for a Lanner Account at http://www.lannerinc.com/ to access published documents and
downloadable resources.
In addition to contacting your distributor or sales representative, if there are any technical queries, you could
submit a support ticket to our Lanner Technical Support department.
Your feedback is valuable to us, as it will help us continue to provide you with more accurate and relevant
documentation. To provide any feedback, comments or to report an error, please email to
[email protected]m. Thank you for your time.
This document is copyrighted © 2022. All rights are reserved. The original manufacturer reserves the right to
make improvements to the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means
without the prior written permission of the original manufacturer. Information provided in this manual is
intended to be accurate and reliable. However, the original manufacturer assumes no responsibility for its use,
nor for any infringements upon the rights of third parties that may result from such use.
Note or Information
Warning or Important

NCA-4030 User Manual
3
Taiwan Corporate Headquarters
Lanner Electronics Inc.
7F, No.173, Sec.2, Datong Rd.
Xizhi District, New Taipei City 22184,
Taiwan
立端科技股份有限公司
221 新北市汐止區
大同路二段 173 號7樓
T: +886-2-8692-6060
F: +886-2-8692-6101
China
Beijing L&S Lancom Platform Tech. Co., Ltd.
Guodong LOFT 9 Layer No. 9 Huinan Road,
Huilongguan Town, Changping District, Beijing
102208 China
T: +86 010-82795600
F: +86 010-62963250
E: service@ls-china.com.cn
USA
Lanner Electronics Inc.
47790 Westinghouse Drive
Fremont, CA 94539
T: +1-855-852-6637
F: +1-510-979-0689
E: sales_us@lannerinc.com
Canada
Lanner Electronics Canada Ltd
3160A Orlando Drive
Mississauga, ON
L4V 1R5 Canada
T: +1 877-813-2132
F: +1 905-362-2369
E: sales_ca@lannerinc.com
Europe
Lanner Europe B.V.
Wilhelmina van Pruisenweg 104
2595 AN The Hague
The Netherlands
T: +31 70 701 3256
E: sales_eu@lannerinc.com

NCA-4030 User Manual
4
Intel® and Intel® Celeron® are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries.
Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp.
All other product names or trademarks are properties of their respective owners.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Follow these guidelines to ensure general safety:
Keep the chassis area clear and dust-free during and after installation.
Do not wear loose clothing or jewelry that could get caught in the chassis. Fasten your tie or scarf and roll up your
sleeves.
Wear safety glasses if you are working under any conditions that might be hazardous to your eyes.
Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
Disconnect all power by turning off the power and unplugging the power cord before installing or removing a chassis
or working near power supplies
Do not work alone if potentially hazardous conditions exist.
Never assume that power is disconnected from a circuit; always check the circuit.
Suivez ces consignes pour assurer la sécuritégénérale :
Laissez la zone du châssis propre et sans poussière pendant et après l’installation.
1. An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent interference
to the nearby radio and television reception. It is essential that only the supplied power cord be used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
1. Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
2. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.

NCA-4030 User Manual
5
Ne portez pas de vêtements amples ou de bijoux qui pourraient être pris dans le châssis. Attachez votre cravate ou
écharpe et remontez vos manches.
Portez des lunettes de sécurité pour protéger vos yeux.
N’effectuez aucune action qui pourrait créer un danger pour d’autres ou rendre l’équipement dangereux.
Coupez complètement l’alimentation en éteignant l’alimentation et en débranchant le cordon d’alimentation avant
d’installer ou de retirer un châssis ou de travailler à proximité de sources d’alimentation.
Ne travaillez pas seul si des conditions dangereuses sont présentes.
Ne considérez jamais que l’alimentation est coupée d’un circuit, vérifiez toujours le circuit. Cet appareil génère, utilise
et émet une énergie radiofréquence et, s’il n’est pas installé et utilisé conformément aux instructions des fournisseurs
de composants sans fil, il risque de provoquer des interférences dans les communications radio.
There is risk of explosion if the battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Installation should be conducted only by a trained electrician or only by an electrically trained person who knows all
installation procedures and device specifications which are to be applied.
Do not carry the handle of power supplies when moving to another place.
Please conform to your local laws and regulations regarding safe disposal of lithium battery.
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in an
explosion.
Leaving a battery in an extremely high temperature environment can result in an explosion or the leakage of
flammable liquid or gas.
A battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or gas.
Risque d’explosion si la pile est remplacée par une autre d’un mauvais type.
Jetez les piles usagées conformément aux instructions.
L’installation doit être effectuée par un électricien formé ou une personne formée à l’électricité connaissant toutes les
spécifications d’installation et d’appareil du produit.
Ne transportez pas l’unité en la tenant par le câble d’alimentation lorsque vous déplacez l’appareil.
Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment to acceptable
operating temperatures without adequate circulation. Be sure that the room in which you choose to operate your
system has adequate air circulation.
Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An open chassis
permits air leaks, which may interrupt and redirect the flow of cooling air from internal components.
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when
electronic components are improperly handled and can result in complete or intermittent failures. Be sure to follow
ESD-prevention procedures when removing and replacing components to avoid these problems.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. If no wrist strap is available, ground
yourself by touching the metal part of the chassis.
Periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms (Mohms).
L’équipement électrique génère de la chaleur. La température ambiante peut ne pas être adéquate pour refroidir
l’équipement à une température de fonctionnement acceptable sans circulation adaptée. Vérifiez que votre site
propose une circulation d’air adéquate.
Vérifiez que le couvercle du châssis est bien fixé. La conception du châssis permet à l’air de refroidissement de bien
circuler. Un châssis ouvert laisse l’air s’échapper, ce qui peut interrompre et rediriger le flux d’air frais destiné aux
composants internes.
Les décharges électrostatiques (ESD) peuvent endommager l’équipement et gêner les circuits électriques. Des dégâts
d’ESD surviennent lorsque des composants électroniques sont mal manipulés et peuvent causer des pannes totales
ou intermittentes. Suivez les procédures de prévention d’ESD lors du retrait et du remplacement de composants.

NCA-4030 User Manual
6
Portez un bracelet anti-ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est disponible,
reliez votre corps àla terre en touchant la partie métallique du châssis.
Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et 10 mégohms
(Mohms).
Mounting Installation Precautions
The following should be put into consideration for rack-mount or similar mounting installations:
Do not install and/or operate this unit in any place that flammable objects are stored or used in.
The installation of this product must be performed by trained specialists; otherwise, a non-specialist might create the
risk of the system’s falling to the ground or other damages.
Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient strength for supporting the
system or use of inappropriate installation components.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing
the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the
manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow required for safe
operation of the equipment is not compromised.
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the
effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Grounding - Reliable grounding of rack mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Installation & Operation
This equipment must be grounded. The power cord for product should be connected to a socket-outlet with earthing
connection.
Cet équipement doit être mis à la terre. La fiche d'alimentation doit être connectée à une prise de terre correctement
câblée
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code
and NFPA 75.
Peut être installé dans des salles de matériel de traitement de l'information conformément à l'article 645 du National
Electrical Code et àla NFPA 75.
The machine can only be used in a restricted access location and must be installed by a skilled person.
Les matériels sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT.
Warning
Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground
socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
“Product shall be used with Class 1 laser device modules.”
Avertissement
Équipement de classe I. Ce matériel doit être relié à la terre. La fiche d’alimentation doit être raccordée à une prise de
terre correctement câblée. Une prise de courant mal câblée pourrait induire des tensions dangereuses sur des parties
métalliques accessibles.
“Le produit doit être utilisé avec des modules de dispositifs laser de classe 1.”

NCA-4030 User Manual
7
Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding) is very
important to protect the equipment against the harmful effects of external noise and to reduce the risk of electrocution
in the event of a lightning strike. To uninstall the equipment, disconnect the ground wire after turning off the power. A
ground wire (green-and-yellow) is required and the part connecting the conductor must be greater than 4 mm2 or 10
AWG.
Avant d’allumer l’appareil, reliez le câble de mise à la terre de l’équipement à la terre.
Une bonne mise à la terre (connexion à la terre) est très importante pour protéger l’équipement contre les effets
néfastes du bruit externe et réduire les risques d’électrocution en cas de foudre.
Pour désinstaller l’équipement, débranchez le câble de mise à la terre après avoir éteint l’appareil.
Un câble de mise àla terre est requis et la zone reliant les sections du conducteur doit faire plus de 4 mm2 ou 10 AWG.
Connect the grounding cable to the ground.
The protection device for the DC power source must provide 30 A current.
This protection device must be connected to the power source before DC power.
Branchez le câble de mise à la terre à la terre.
L’appareil de protection pour la source d’alimentation CC doit fournir 30 A de
courant.
Cet appareil de protection doit être branché à la source d’alimentation avant
l’alimentation CC.

NCA-4030 User Manual
8
Main Features.................................................................................................................................10
Package Content.............................................................................................................................10
Ordering Information .....................................................................................................................10
Optional Accessories ......................................................................................................................10
System Specifications.....................................................................................................................11
Front Panel .....................................................................................................................................12
Rear Panel.......................................................................................................................................13
Block Diagram.................................................................................................................................14
Jumpers and Connectors................................................................................................................15
Opening the Chassis .......................................................................................................................20
Installing the System Memory .......................................................................................................21
Installing M.2 Memory Card (Optional) .........................................................................................23
Installing TPM Module (Optional)..................................................................................................24
Installing Disk Drive(s) (Optional)...................................................................................................25
Installing NIC Modules....................................................................................................................27
Installing PGN Module (Optional) ..................................................................................................28
Mounting the System.....................................................................................................................31
Main Page.......................................................................................................................................38
Advanced Page ...............................................................................................................................39

NCA-4030 User Manual
9
Platform..........................................................................................................................................58
Socket .............................................................................................................................................63
Server Mgmt...................................................................................................................................74
Security...........................................................................................................................................79
Boot Menu......................................................................................................................................82
Save and Exit Menu........................................................................................................................83
Warranty Policy ..............................................................................................................................86

NCA-4030 User Manual
10
The NCA-4030 is based on Intel Xeon D, a branch of Xeon processors optimized for delivering ultra-low power
consumption and robust performance. This appliance comes with the most innovative System-on-a-Chip built
for the edge and is ideal for applications in networking, 5G and IoT/IIoT Edge computing, delivering
improvement in packet processing performance, virtualized Customer Premise Equipment (vCPE) usages.
Intel® Xeon D-1700 4~10 Cores
4x DDR4 2933MHz, Max. 128GB
4x 1G RJ45, 1x 2.5G RJ45, 1x 1G RJ45 (LOM), 4x 10G SFP+
2x NIC Slots, 1x RJ45 Console, 2x USB 3.0
2x 2.5” Internal HDD/SSD Bays, 1x M.2 2242
3x Fans, 450W 1+1 Redundant PSUs
Your package contains the following items:
1x NCA-4030 Network Security Platform
1x Power Cable
2x Console Cable
2x SATA Cable
Nameplate
1x Short Ear Rackmount Kit (with screws)
SKU No.
Main Features
NCA-4030A
Intel Ice Lake D, 10C, 5x 1G RJ45, 1x 1G RJ45(LOM), 4x 10G SFP+, 2x NIC Module Slots
NCA-4030B
Intel Ice Lake D, 8C, 4x 1G RJ45, 1x 2.5G RJ45, 1x 1G RJ45 (LOM), 4x 10G SFP+, 2x NIC Slots
NCA-4030C
Intel Ice Lake D, 4C, 4x 1G RJ45, 1x 2.5G RJ45, 1x 1G RJ45 (LOM), 4x 10G SFP+, 2x NIC Slots
Model
Description
PCIe Cable
PCIe cable for rear side PCIe expansion (By Project)
IAC-TPM04A
TPM 2.0 Module Card
PGN-300
4G LTE Radio Modem with LTE Cat-6 Embedded Module
PGN-600
4G LTE Radio Modem with LTE Cat-12 Embedded Module
1U Rackmount Kit
1U Slide Rackmount Rail Kit with screw pack

NCA-4030 User Manual
11
Form Factor
1U 19” Rackmount
Platform
Processor Options
Intel® Xeon® D-1700
CPU Cores/TDP
SKU A: 10C, 85W;
SKU B: 8C, 67W;
SKU C: 4C, 45W
CPU Socket
1x Onboard LGA1150
Security Acceleration
Intel® QuickAssist Technology (By SKU)
BIOS
AMI SPI Flash BIOS
System Memory
Technology
DDR4 2933MHz REG or ECC/Non-ECC RDIMM
Max. Capacity
128GB
Socket
4x 288-pin DIMM
Networking
Ethernet Ports
1x 2.5G RJ45 Intel® i226-AT (MGMT Port);
5x 1G RJ45 LAN Ports
4x 10G SFP+ Ports
NIC Module Slot
2x NIC slots
LOM
I/O Interface
1x 1G RJ45 LOM Port (via BMC)
OPMA Slot
Yes
I/O Interface
Reset Button
1x Reset Button
LED Indicator
Power/Status/Storage, refer to Appendix A
Power Button
1x ATX Power Button
Console Port
1x 2.5G RJ45 Console Management Port
USB Port
2x USB 3.0 Ports
LAN Port
4x 1G RJ45 Ethernet Ports;
4x 10G SPF+ Ports;
LOM Port
1x 1G RJ45 LOM Port
Power Input
AC Power Inlet on PSU
Storage
HDD/SSD Support
2x 2.5” Internal HDD/SSD Storage bays
Onboard Slots
1x M.2 (SATA) 2242 B-Key
Expansion
PCIe
1x PCI-E*8 FH/HL (Optional),
1x PGN LTE Module (Optional)
Miscellaneous
Watchdog
Yes
Internal RTC with Li Battery
Yes
TPM
Yes (Optional)
Cooling
Processor
Passive CPU Heatsink
System
3x Individual Cooling Smart Fans
Environmental Parameters
Temperature
0~40ºC Operating,
-20~70ºC Non-Operating
Humidity (RH)
5~90% Operating,
5~95% Non-Operating
System Dimensions
Size (WxDxH)
438 x 44 x 510mm
Weight
9.4 kg
Package Dimensions
(WxDxH)
739 x 215 x 582 mm
Weight
13 kg
Power
Type/Watts
450W 1+1 Redundant PSU
Input
AC 90~264V @47~63 Hz
OS Support
Linux
Approvals and Compliance
CE/FCC Class A, UL, RoHS

NCA-4030 User Manual
12
No.
Description
F1
LED Indicators
Power/Status/Storage, pls refer to Appendix A
F2
Reset Button
1x Reset Button
F3
Console Port
1x 2.5G RJ45 Console Management Port
F4
USB Port
2x USB 3.0 Ports
F5
SFP Port
4x 10G SFP+ Ports
F6
LAN Port
5x 1G RJ45 Ethernet Ports
F7
LOM Port
1x 1G RJ45 LOM Port (for remote management)
F8
PGN Module
1x Removable PGN Module Slot (Optional)
F9
NIC Module
2x NCS2 Slim Type NIC Module (Optional)
F1
F2
F3
F8
F9
F6
F4
F5
F7

NCA-4030 User Manual
13
No.
Description
R1
Power Supply
450W 1+1 Redundant PSU
R2
Rear PCIe Expansion
1x PCIe*8 FH/HL (Optional)
R3
ESD Jack
1x ESD Jack
R4
Ground Hole
2x Grounding Holes
R5
Reset Button
1x Reset Button
R6
Power Switch
1x Slim Type ATX ON/OFF Button
R7
Smart Fans
3x Independent Swappable Smart Fans
R4
R5
R1
R2
R6
R7
R3

NCA-4030 User Manual
14

NCA-4030 User Manual
15
The following displays the connectors and jumpers on the motherboard layout.
1~3 (JFAN1 ~ JFAN3): Fan Connector M-180°
4~6 (JFAN4~JFAN6): Fan Connector M-RA
7~8 (JATX3~JATX4): To Power Board 12V Power Connector
9~10 (JATX1~JATX2): To PCIe Card Power Connector
11 (J7): To Power Board
12 (JALAM1): Buzzer Alert

NCA-4030 User Manual
16
13 (JPWR1): PWRBTN
14 (J8): Power PMBUS
15 (Type C): USB 3.0 Port1 (Type C) PGN Module CONN
16 (CON1): SIM Select Control Pin
17~18 (JPCIEG1~JPCIEG2): PCIe Gen4 Connector
19~20 (JSASHD1~JSASHD2): MiniSAS Connector (SATA)
21 (PCIESLOT1): PCIE Gen3 Slot
22 (JSPI_TPM1): SPI & JSPI_TPM1 Pin Connector
23 (JXDP): XDP Connector (Debug only)
24 (JSATAPW1): SATA HDD Power Connector
25 (JVGA1): VGA Connector
26 (JIDV): IDV Connector (Debug Only)

NCA-4030 User Manual
17
27 (JCMOS1): CMOS Control Pin
28 (BAT1): To BAT Connector
29~30 (JSATA1~JSATA2): SATA Connector
31 (JGP1): GPIO Connector
32 (JSMB1_DEBUG): SMB1 Connector (debug only)
33 (JBMC_REME_DB1): BMC Remote Debug Select Connector
34 (JNGFF1): M.2 Connector
35 (JCOM1): COM Console Port Connector
36~39 (JDDR1~JDDR4): DDR4 DIMM Connector
40 (JLPC_80P1): Debug Port Connector (LPC & ESPI)

NCA-4030 User Manual
18
41 (J14): BIOS Boot Up Select & Dual BIOS Function Select Connector
42 (JBMC1): BMC Update Select Connector
43 (JBMCBG1): RST_SMB_SWITCH Select Connector
44 (JOPEN1): Case Open Connector
45 (J4): JTAG Select Connector
46 (JSMB2_DEBUG): SMB1 Connector (Debug only)
47 (J5): JTAG Connector (CPLD Burn File)
48 (JNMI1): NMI Connector
49 (J9): UART Select Connector

NCA-4030 User Manual
19
50 (JIPMB1): IPMB Connector
51 (JDB1): BMC UART5 Connector (BMC debug)
52 (JRST1): RESET Connector (Do not use)
53 (JBMC_HSBP1): SMB_HSBP_PFR Connector (Do not use)
54~55 (RJ3_RJ2): IG Copper LAN Port (Marvell 88E1543)
56 (RJ1): Up: 2.5G Copper LAN Port (I226);
Down: 1G Copper LAN Port (AST2500 MAC1)
57 (FIBER1): 10G Fiber Port (PHY C827)
58 (JUSBCOM1): RJ45 COM Console Port; USB 3.0 x2
59 (SW2): Reset Button
60 (JSOC_UART1): SOC UART Connector
1 (J11): Flash Security Override

NCA-4030 User Manual
20
To reduce the risk of personal injury, electric shock, or damage to the system, please remove all power
connections to shut down the device completely and wear ESD protection gloves when handling the installation
steps.
1. Power off the system and remove all
power connections.
2. Remove the two (2) screws on the rear
panel.
3. Gently pull the top cover backwards and
lift the chassis cover up to remove.
Table of contents
Other Lanner Network Hardware manuals

Lanner
Lanner IIOT-I530 User manual

Lanner
Lanner FW-7580 User manual

Lanner
Lanner NCA-2510 User manual

Lanner
Lanner uCPE NCA-4020 User manual

Lanner
Lanner NCA-5230 User manual

Lanner
Lanner LWR-X8460 User manual

Lanner
Lanner ICS-P570 User manual

Lanner
Lanner NCA-1513 User manual

Lanner
Lanner FW-8771 User manual

Lanner
Lanner HLM-1101 User manual

Lanner
Lanner IIOT-I330 User manual

Lanner
Lanner NCS2-VT04 User manual

Lanner
Lanner IIOT-I531 User manual

Lanner
Lanner FX-3230 User manual

Lanner
Lanner NCA-1515 User manual

Lanner
Lanner NCA-5540 User manual

Lanner
Lanner NCA-2523 User manual

Lanner
Lanner NCA-2512 User manual

Lanner
Lanner NCR-1510 User manual

Lanner
Lanner ECA-4027 User manual