POWER
DC INPUT
DC 9V-12V
300mA min
ON OFF
DMX OUTPUT
1 = Ground
2 = Data -
3 = Data +
1
2
3
VersiLED 6
www.prolight.co.uk
IO

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProlight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thisxtureisforprofessionaluseonly-itisnotdesigned
fororsuitableforhouseholduse.Theproductmustbe
installedbyaqualiedtechnicianinaccordancewithlocal
territoryregulations.Thesafetyoftheinstallationisthe
responsibilityoftheinstaller.Thexturepresentsrisksof
severeinjuryordeathduetorehazards,electricshock
andfalls.
• WARRANTY:Oneyearfromdateofpurchase.

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 3
Product overview & technical specications
TheVersiLED6fromLEDJisauniversalDMXcontrollerdesignedforcontrollingmulticolourLEDxtures.Suitable
forusewithRGB,RGBW,RGBWAorRGBWAUVproducts,withorwithoutdimmerchannelsthecontrollermaybe
usedforLEDparcans,panelsorevenLEDstriplights.
VersiLED 6 DMX Controller
• Cancontroluptofourxtures/groupsfromRGB+dimmer
throughtoRGBWA+UV,eachxturemaybesetindividually
• Masterdimmerfunction,evenforRGBWA+UVproducts
• SeparateRGBWandAmber/UVcolourmixonfadercontrol
• LTPcontrolsystemforintuitiveoperation
• Strobefunctionwithadjustablespeed(1-20Hz)
Specications VersiLED 6
Powersupply DC9V-12V,300mAmin
(byadaptorincluded)
Dimensions 60x250x110mm
Weight 1kg
Ordercode LEDJ322
BLACKOUT STROBE
M1 M4
M2 M5
M3 M6
CHANNEL
MODE
M1: RGBD
M2: RGBWD
M3: RGBWAD
M4: RGBWAUV
M5: DRGBWAUV
M6: RGBWAUVD
0
100
80
60
40
20
R G W A UV/D
0
100
80
60
40
20
0
100
80
60
40
20
0
100
80
60
40
20
0
100
80
60
40
20
SPEED
30
SEC
0.1
SEC
1-10
1
11-20
2
21-30
3
31-40
4AUTO SOUND
RUN MODE
B
DIMMER/
STROBE
SPEED
SOUND
SENSITIVITY
0
100
80
60
40
20
R G B
RGBW
MIX
AUV
MIX
W A UV
A UVR G B W
MACRO
1
8
7
6
5
4
3
2
VersiLED 6
POWER
DC INPUT
DC 9V-12V
300mA min
ON OFF
DMX OUTPUT
1 = Ground
2 = Data -
3 = Data +
1
2
3
VersiLED 6
www.prolight.co.uk
IO
01-RGBWAUV/Dchannelfaders
02-Fixture/groupbuttons&LEDindicators
03-Channelmodeselection&LEDindicators
04-Runmodeselect(autoorsound)
05-Blackoutbutton
06-Strobebutton
07-RGBWcolourmix
08-Amber/UVcolourmix
09-Colourmacrofader
10-Speedcontrol
11-Strobespeed/soundsensitivity/
masterdimmer
12-3-PinDMXoutput
13-DCpowerinput(centre+ve)
14-Poweron/offswitch
Inthebox:
1 x controller,
1 x power adaptor
& 1 x user manual
01
12 13 14
02
04 05 06
03 07 08 09 10 11

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 4
Initial setup:
ConnectthesuppliedmainspoweradaptortotheDCpowerinputonthecontrollerandthentoa
suitablemainsvoltagesupply(100-240VAC~50/60Hz).
Thecontrollercanbeusedtocontrol3,4,5or6colourLEDproductseachwithorwithouta
dimmerchannel.
ThecontrollerisbasedaroundLTP(LastTakesPrecedence)acrossitscontrolsurface,thismeansthe
lastcommandexecutedonthecontrollerwilloverridethepreviouscommand.Becauseofthis,the
controlleriseasytouseforthosewhocarrylittleknowledgeofDMXcontrollers.
DMX channel assignment:
ThecontrollerhaspresetDMXstartaddressesforeachofthefourxtures.Pleasesetyourxturetothe
followingDMXaddresses.
Pleasenote:IftwoormorexturesaresettothesameDMXaddresstheywillreceivethesame
DMXcommands.
Master dimmer:
ThecontrolleralsohasanadditionalMasterDimmerfunction.WhileholdingdowntheBlackout
button,usethestrobe/dimmerfadertoadjusttheoverallmasterintensity.Thisfunctionwilloperatefor
allxturesregardlessofxtureselection.Themasterdimmerfunctionwilloverridealloutputsincluding
soundandautomodes.Ifyouhaveusedthemasterdimmertodimyourxture(s)tozeroyouwillhave
todimthembackupinordertousemanualdimming/colourmixingagain.
01) RGBWAUV/D channel faders:
TheRGBWAUV/Dfadersareusedtocreateamanualcolourmix.Firstselectthexturegroups
asrequiredfromthefourxturegroupsandthenusethefaderstoadjustthecolourandintensity
asrequired.
02) Fixture/group buttons and LED indicators:
Thexture/groupbuttonsareusedtoselectordeselectxtures.NexttoeachbuttonisanLED
indicator,thiswillilluminatewhenthexturesareselected.
Operating instructions
Fixture Number Group DMX Start Address
1001
2011
3021
4 031

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 5
03) Channel mode selection and LED indicators:
Thecontrollercanbeusedtocontroluptofourxtures/groupsfromRGBthroughtoRGBWA+UV,each
xturemaybesetindividuallytosuittheDMXchannelsofyourLEDxturesfromRGB+Dimmerupto
andincludingRGBWAUV+Dimmer.Selectthedesiredxture/groupusingthexture/groupbuttons,then
selectthechannelmode.Unselectthexture/groupandthenrepeattheprocessforeachofthefour
xture/groupsuntilset.Pleasenote:WhenusingMode5andMode6,thedimmerchanneloutputvalue
willbe255,thisenablesyoutocolourmixandthenusethemasterdimmerdetailedabove.
Fader allocation VS Mode chart:
04) Run mode select (auto or sound):
Thebuilt-incolourmacro’smaybetriggeredbyeithersoundcontrolorautowithspeedcontrol.
PresstheRunModebuttontochangebetweensoundorautocontrol.TheLEDindicatorwill
illuminatetoshowtheRunMode.Usethespeedandsoundsensitivityfaderstoadjusttheauto
speedorsoundsensitivity.
05) Blackout button:
Theblackoutcontrolcanbeusedforinstantblackout(off)commandsofthexturescontrolledbythe
VersiLED6controller.Theblackoutbuttonisaglobalcommandandwillcontrolthexturesregardless
ofanyxture/groupselection.
PressandholdtheblackoutbuttontoenabletheMasterDimmerfunctionandatthesametimeusethe
strobespeed/dimmerfadertocontroloverallintensityofthedimmerchannels.Thiswillalsofunctionas
aglobalcommandandwillcontrolthexturesregardlessofanyxture/groupselection.
06) Stobe button:
PressandholdtheStrobebuttontoactivateawhitestrobeacrossthexturesselectedonthexture/
group.Whileholdingthebutton,thestrobespeedcanbeadjustedusingthestrobespeed/sound
sensitivity/dimmerfader.Thestrobespeedisadjustable1Hz-20Hz.Pleasenote:Ifthemasterdimmer
functionhasbeensettozerothenthestrobewillnotoperate.Pleasesetthemasterdimmerbackupfor
thestrobetofunctionagain.
07) RGBW colour mix:
TheRGBWcolourmixfadercanbeusedforrapidselectionofstaticcolours.Pushthefadertofadefrom
Red,throughGreenandBlueuptofullonattheupperlimitofthefader.
Operating instructions
Mode Fader 1 Fader 2 Fader 3 Fader 4 Fader 5 Fader 6 DMX Allocation
M1 RGBD Red Green Blue Dimmer - - RGB+CH4MasterDimmer
M2 RGBWD Red Green Blue White Dimmer - RGBW+CH5MasterDimmer
M3 RGBWAD Red Green Blue White Amber Dimmer RGBWA+CH6MasterDimmer
M4 RGBWAUV Red Green Blue White Amber UV RGBWAUV
M5 DRGBWAUV Red Green Blue White Amber UV RGBWAUV+CH1(xedat255)
M6 RGBWAUVD Red Green Blue White Amber UV RGBWAUV+CH7(xedat255)

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 6
Operating instructions
08) Amber/UV colour mix:
TheAmber/UltraVioletcolourmixfadercanbeusedforrapidselectionofstaticcolours.Pushthefader
tofadefromAmberthroughtoUltraVioletuptofullonattheupperlimitofthefader.Thefadermaybe
usedinconjunctionwiththeRGBWcolourmixtoaddAmberorUltraVioletintotheRGBWmixedcolours.
09) Colour macro fader:
TheVersiLED6controllerhasbuiltinRGBWAUVcolourmacro’sthatcanbetriggeredbysoundwith
adjustablesensitivityorautowithspeedcontrol.Selectthedesiredxture/groupsandthenusethe
macrofadertoselectfromoneoftheeightinternalcolourmacros.Theautospeedcanbesetusing
thespeedfader,whilethesoundsensitivitycanbesetusingthestrobespeed/soundsensitivity/master
dimmerfader.
10) Speed control:
Thespeedcontrolfaderisusedtoadjustthespeedofthebuiltincolourmacros.
11) Strobe speed/sound sensitivity/master dimmer:
Thestrobespeed/soundsensitivity/masterdimmerfaderprovidescontrolformultiplefunctions
onthecontroller.
12) 3-Pin DMX output:
DMXoutputconnection.3-pinXLRoutputsocket.Pin1=Ground,Pin2=data–ve,Pin3=data+ve
13) DC power input (centre +ve):
Centrepositivetypeconnection.9-12VDC,300mAminimumregulatedtype.
14) Power on/off switch:
Usethisswitchtopowerthecontrolleron/off.
Macro Channel Value Description
N/A 000-007 Blackout
1 008-038 RGBFade
2039-069 RGBChange
3070-100 RGBWFade
4 101-131 RGBWChange
5 132-162 Red/GreenChange
6 163-193 Red/BlueChange
7 194-224 Green/BlueChange
8 225-255 RGBWAUVChange

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 7
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 8
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 9
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 10

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 11

www.prolight.co.uk VersiLED 6 DMX Controller User Manual 12
Table of contents
Other Ledj Controllers manuals
Popular Controllers manuals by other brands

Lenz
Lenz Digital plus LH101 operating manual

SainSmart
SainSmart 2M542 operating manual

Speed Passion
Speed Passion Reventon wireles Bluetooth Unit user manual

Duplomatic Oleodinamica
Duplomatic Oleodinamica EWM-SP-DAD/20E Startup manual

Hydrofarm
Hydrofarm autopilot APC8400 user manual

Carel
Carel AT th Tune Series manual

Omron
Omron NSJ Series Connection guide

Mitsubishi Electric
Mitsubishi Electric ME1PB1-L installation manual

FUTABA
FUTABA CGY750 instruction manual

Rockwell Automation
Rockwell Automation Allen-Bradley AADvance T9110 System Build Manual

TOPP
TOPP C240 Installation and use instructions

D-Box
D-Box HaptiSync Hub quick start guide