manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lemo
  6. •
  7. Cables And Connectors
  8. •
  9. Lemo DCS.F2.N02.PA User manual

Lemo DCS.F2.N02.PA User manual

www.lemo.com
DCS.F2.N02.PA Instruction Manual
STANDARD
EXTENDED
TO EXTENDNOZZLE
DEPRESS BLACK BUTTON
ANDPULL NOZZLE
Push Lock Button
Pull Nozzle
Extended ModeStandard Mode
C. Lock Button
D.Outer Shell
F. Indicator
E. Cover
G. F2 Guide Cap male
B. Nozzle
A. Tip
STANDARD
EXTENDED
TO EXTEND NOZZLE
DEPRESS BLACK BUTTON
AND PULLNOZZLE
Full
View of Indicator View of the Nozzle end
Little
Empty
Cloth (White)
Tip (Black)
Tip (Black)
Cloth
(White)
Red
Cloth
(White)
Red
No Cloth (Black)
Identification of remaining cloth
No
A
B
C
D
E
F
G
Tip Lead the cleaning cloth to the optical connector end face
Nozzle Lead tip to the optical connector end face
Lock Button Push the button to extend and contract the nozzle
Outer Shell Push the outer shell to clean the connector
Cover Avoids contamination of tip
Indicator Provides indication of remaining cleaning cloth
F2 Guide Cap male For use with F2 male contact
Part Name Function
The DCS.F2.N02.PA is a high-performance device designed for cleaning the ferrule end faces of LEMO’s fiber optic
F2 contacts. Carefully read this instruction manual before using this device.
Please keep this instruction manual for future reference.
For use with LEMO F2 contacts such as:
FFS.F2.BA2.LCE30 (male contact) FFS.F2.BA2.LCT10 (male contact)
PSS.F2.BA2.LCE30 (female contact) PSS.F2.BA2.LCT10 (female contact)
FFT.F2.BA2.LCE10 (male contact field terminated) PST.F2.BA2.LCE10 (female contact field terminated)
These contact types are commonly used in the 3K.93C Series broadcast connectors (SMPTE connectors).
1. Safety precautions
Though our device is deemed safe, improper usage or handling can still inflict injury to others.
The DCS.F2.N02.PA is designed to clean ANSI/SMPTE (304 M-1009 and 311M-1998) based connectors, or other LEMO
connectors with F2 contacts.
LEMO is not liable for damage caused in attempt to apply this device to other applications.
2. Notes on usage
Do not attempt to disassemble as this can cause damage to the device.
Do not re-use cleaning cloth as this will eliminate its cleaning ability.
Do not touch the cleaning cloth as this will cause contamination.
Do not pull the cleaning cloth, use only the device body.
Do not use this cleaner when the cloth is empty, as this can cause damage to the connector.
3. Notes on storage for extended periods
Do not expose device to direct sunlight, high temperature or high humidity.
The cover on the guide cap should be closed at all times when device is not in use.
4. Device construction
DCS.F20910.doc September 2010
www.lemo.com
LEMO USA Inc.
Tel :707-578-8811 Fax : 707-578-0869 Toll Free : 800-444-5366
E-mail : [email protected] http://www.lemo.com
6. Applications
Female F2 contact cleaning
1. Remove Guide Cap and cover from the device.
2. Insert tip of cleaner into sleeve of the connector
3. Push the Outer Shell to start cleaning the F2 contact.
A “click” sound indicates end of cleaning process.
Close the cover after use.
Male F2 contact cleaning
1. Open the Cover on the Guide Cap.
2. Insert tip of cleaner into sleeve of the connector
with the F2 Guide Cap on.
3. Push the Outer Shell to start cleaning the F2 contact.
A “click” sound indicates end of cleaning process.
Close the cover after use.
Guide Cap
Cover
F2 Guide Cap male
EXTENDED
TOEXTENDNOZZLE
DEPRESSBLACK BUTTON
ANDPULLNOZZLE
Be careful not to slant the DCS.F2.N02.PA while inserting into
the adapter. Do not overly exert force during insertion as this
may cause damage to both the connector and the
DCS.F2.N02.PA Cleaner. If pushing Outer Shell is inhibited,
remove DCS.F2.N02.PA from adapter and ensure that there is
no sizeable debris inhibiting the cleaning process.
Be careful not to slant connector while inserting into the F2
Guide cap. Do not overly exert force during insertion as this
may cause damage to both the connector and the
DCS.F2.N02.PA Cleaner. If pushing Outer Shell is inhibited,
remove DCS.F2.N02.PA from adapter and ensure that there
is no sizeable debris inhibiting the cleaning process.
EXTENDED
STAN
TO EXTEND NOZZLE
DEPRESS BLACK BUTTON
AND PULL NOZZLE
EXTENDED
TO EXTEND NOZZLE
DEPRESS BLACK BUTTON
AND PULL NOZZLE
Push straight
EXTENDED
TO EXTEND NOZZLE
DEPRESS BLACK BUTTON
ANDPULLNOZZLE
Push straight
STANDAR
EXTENDED
TO EXTENDNOZZLE
DEPRESS BLACK BUTTON
ANDPULLNOZZLE

Other Lemo Cables And Connectors manuals

Lemo REDEL 1P User manual

Lemo

Lemo REDEL 1P User manual

Lemo K Series User manual

Lemo

Lemo K Series User manual

Lemo 0F Series User manual

Lemo

Lemo 0F Series User manual

Lemo T Series User manual

Lemo

Lemo T Series User manual

Popular Cables And Connectors manuals by other brands

Lindy 38402 user manual

Lindy

Lindy 38402 user manual

LINK-MI LM-SP142M quick start guide

LINK-MI

LINK-MI LM-SP142M quick start guide

Staubli KBT16BV-NS/M Series Assembly instructions

Staubli

Staubli KBT16BV-NS/M Series Assembly instructions

Philips SWV4114S/10 user manual

Philips

Philips SWV4114S/10 user manual

Raychem TRACETEK TT3000 SERIES installation instructions

Raychem

Raychem TRACETEK TT3000 SERIES installation instructions

Ametek Land Spot installation guide

Ametek

Ametek Land Spot installation guide

Simon 10000561-039 Installation

Simon

Simon 10000561-039 Installation

Kramer CLS-AOCH/xl installation instructions

Kramer

Kramer CLS-AOCH/xl installation instructions

NEUTRIK Easycon EZ Series Assembly instructions

NEUTRIK

NEUTRIK Easycon EZ Series Assembly instructions

Acom 3x2000A operating manual

Acom

Acom 3x2000A operating manual

Keysight Technologies Y1245A installation guide

Keysight Technologies

Keysight Technologies Y1245A installation guide

Actisense OPTO-4 quick start guide

Actisense

Actisense OPTO-4 quick start guide

IFM CR3132 manual

IFM

IFM CR3132 manual

CONDUCTIX SR10 Installation operation & maintenance

CONDUCTIX

CONDUCTIX SR10 Installation operation & maintenance

Meltric SP operating instructions

Meltric

Meltric SP operating instructions

Hyperkin M07433 quick start guide

Hyperkin

Hyperkin M07433 quick start guide

Dietzel Univolt Univolt MIFS installation guide

Dietzel Univolt

Dietzel Univolt Univolt MIFS installation guide

Extron electronics STP24LC Specification sheet

Extron electronics

Extron electronics STP24LC Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.