7
7 MARKING
The outside of the device is provided with external marking positioned in a visible
place. Marking includes:
- Producer trademark
- Part no.
- Batch number and production date. Example: A18 NS1-123456. The batch's first
letter refers to the month of manufacture (A=January, B=February, etc.). The second
and third digits indicate the production year (18 =2018, 19=2019, etc.).
8 TECHNICAL DATA
8.1 Housing
Housing made of glass fiber reinforced, self-extinguishing and shock-proof
technopolymer
Degree of protection: IP67 acc. to EN 60529
IP69K acc. to ISO 20653
(Protect the cables from direct high-pressure and high-temperature water jets)
8.2 General specifications
Locking with guard interlocking,
contact-free, coded: Type 4 according to EN ISO 14119
Encoding level acc. to EN ISO 14119: Low level with AC-L250-SCA actuator
High with AC-L250-UCA actuator
SIL*
PL*
Cat.*
PFHDMTTFD
Mode 1 / Mode 2
Interlock monitoring function (protec-
tive device closed)
3 e 4 1.22E-09 1840
Locking function (protective device
locked) - Not available in mode 2
3 e 4 1.23E-09 2657
Monitoring of the protective device
locking function
3 e 4 2.29E-10 2243
System (general) 3 e 4 1.24E-09 1671
Mode 3
Interlock monitoring function (protec-
tive device closed)
2 d 2 1.49E-09 3987
Locking function (protective device
locked)
2 d 2 1.50E-09 2627
Monitoring of the protective device
locking function
3 e 4 2.04E-10 2254
System (general) 2 d 2 1.82E-09 1677
(*) Values that can be achieved by the device. The final values of the safety application on the
machine always depend on the external devices, circuit and wiring.
DC: High
Mission time: 20 years
Ambient temperature: -20°C … +50°C
Storage temperature: -40°C … +75°C
Maximum operation altitude: 2000 m
Time for starting the switching operation: 2 s
Maximum actuation frequency with
actuator lock and release: 600 switching cycles/hours
Mechanical life expectancy: 1 million switching cycles
Max. actuation speed: 0.5 m/s
Min. actuation speed: 1 mm/s
Installation position: Any
Max. force before breakage F1max: 2100 N according to EN ISO 14119
Max. locking force FZh: 1615 N according to EN ISO 14119
Play of locked actuator: 4 mm
Extraction force of unlocked actuator: ~ 20 N
8.3 Electrical data
8.3.1 Electrical data of power supply
Nominal operating voltage Ue: 24 VDC ±10% SELV
Operating current at Uevoltage:
- minimum: 40 mA
- with electromagnet activated: Max. 0.4 A
- with electromagnet activated and
all outputs at maximum power: 1.2 A
Rated insulation voltage Ui: 32 VDC
Rated surge withstand voltage Uimp: 1.5 kV
External safeguarding: 2 A type gG or equivalent safeguarding
Overvoltage category: III
Electrical life expectancy: 1 million switching cycles
Electromagnet switch-on time: 100% ED
Max. electromagnet power consumption: 9 W
Degree of contamination: 3 according to EN 60947-1
8.3.2 Electrical data of IS1/IS2/I3/IE1/IE2/I5/EDM inputs
Nominal operating voltage Ue1: 24 VDC
Rated current consumption Ie1: 5 mA
8.3.3 Electrical data of OS1/OS2 safety outputs
Nominal operating voltage Ue2: 24 VDC
Output type: OSSD, PNP
Maximum current for output Ie2: 0.25 A
Minimum current for output Im2: 0.5 mA
Therm. nominal current Ith2: 0.25 A
Usage category: DC-13; Ue2=24 VDC, Ie2=0.25 A
Short-circuit detection: Yes
Overcurrent protection: Yes
Internal self-resetting protection fuse: 1.1 A
Time for deactivation pulses on
safety outputs: < 300 µs
Maximum permissible capacitance
between outputs: < 200 nF
Maximum permissible capacitance
between output and ground: < 200 nF
Response time for OS1 and OS2 safety
outputs on input deactivation: Typically 7 ms, maximum 15 ms
Response time upon release
of the actuator: Typically 7 ms, max. 12 ms
Response time upon removal
of the actuator: Typically 120 ms, max. 200 ms
Maximum delay for EDM input
signal state change: 500 ms
8.3.4 Electrical data of O3/O4 signal outputs
Nominal operating voltage Ue3: 24 VDC
Output type: PNP
Maximum current for output Ie3: 0.1 A
Usage category: DC-13; Ue3=24 VDC, Ie3=0.1 A
Short-circuit detection: No
Overvoltage protection Yes
Internal self-resetting protection fuse: 1.1 A
8.3.5 RFID sensor data
Assured operating distance Sao: 2 mm
Assured cut-out distance Sar: 6 mm (actuator not locked)
10 mm (actuator locked)
Nominal switching distance Sn: 3 mm
Repeatability: ≤10% Sn
Differential travel: ≤20 % Sn
Maximum switching frequency: 1 Hz
Min. distance between 2 identical devices
to avoid reciprocal radio interferences: 0 mm
8.4 Conformity with standards
EN ISO 14119:2013, EN 60947-5-3:2013, EN 60947-1, EN 60204-1, EN ISO 12100,
EN 60529, EN 61000-6-2, EN 61000-6-3, BG-GS-ET-19, IEC 61508:2010, SN 29500,
EN ISO 13849-1:2015, EN ISO 13849-2:2012, EN 62061:2005 + A2:2015, EN 61326-1,
EN 61326-3-1, EN 61326-3-2, ETSI 301 489-1, ETSI 301 489-3, ETSI 300 330-2,
UL 508, CSA 22.2 No.14
8.5 Conformity with directives
Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU, Radio Equipment Direc-
tive 2014/53/EU, RoHS Directive 2011/65/EU
Statements acc. to FCC Part 15: This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired
operation.
9 SPECIAL VERSIONS ON REQUEST
Special versions of the device are available on request.
The special versions may differ substantially from the descriptions in these operating
instructions.
The installer must ensure that he has received written information from the support
service regarding installation and use of the special version requested.
10 DISPOSAL
At the end of its mission time, the device must be disposed of properly, according to
the rules in force in the country in which the disposal takes place.
11 SUPPORT
The device can be used for personnel protection. For questions or doubts concerning
installation or use, always contact our technical customer service under the following
contact address:
24-hour on-call service at: +49 7021 573-0
Service hotline: +49 7021 573-123
Return address for repairs:
Service center
Leuze electronic GmbH + Co. KG
In der Braike 1
D-73277 Owen / Germany
12 EC CONFORMITY DECLARATION
Leuze electronic GmbH + Co. KG
In der Braike 1, D-73277 Owen/Germany
The safety sensors of the L300 series have been developed and manufactured in
accordance with the applicable European standards and directives.
The manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen,
possesses a certified quality assurance system in accordance with ISO 9001.
© 2019 Copyright Leuze electronic. All rights reserved.