LevelOne Infinity IEC-2000 User manual

IEC-2000
10/100/1000 Industrial Media Converter, SFP -40 to 75C
Quick Installation Guide
v1.00‐1209
IEC-2000 Page 1
Overview
LevelOne IEC-2000 is an industrial Gigabit Ethernet media converter
with a rugged aluminium case which providing superb heat
dissipation. This converter is designed to be mounted on an
industrial standard DIN-rail, plus the clearly visible status LEDs
provide simple monitoring of port link activity. It also features Link
Fault Pass Through in order to alert remote location when link
status changes
Fault Detection
Relay contact sends alert signal when the power failed or a port link
disconnected, therefore the system operator can respond quickly.
This relay contact can be easily configured with a simple DIP switch
High Reliability
All components are built to withstand harsh environment
applications without compromise where humidity, temperature
variation and even shock vibration are concerns, including Electric
& Utility, Critical Infrastructure, Transportation and Surveillance
Security. This device operates under -40 to 75 Celsius (-40 to 167
Fahrenheit) temperature.
Safety
Complies with NEMA (National Manufacturers Association) TS1 &
TS2 Environmental certified for the Traffic Control Equipment that
withstand extreme temperatures, operating voltage and humidity
fluctuation, vibration and shock commonly experienced in severe
outdoor environments.
IEC-2000 Page 2
Features
Complies with NEMA TS1 & TS2 Environmental requirements for
Traffic control equipment
Complies with IEC61000-6-2 EMC Generic standard immunity for
Industrial environment
SFP slot supports pluggable Gigabit optic modules that enabling
you to choose from a variety of transceiver
DIP switch configuration for "Link-Fault-Pass-Through," link
down alarm, speed, duplex mode
1000Mbps-Full/Half-duplex, Auto-Negotiation, Auto-MDI/MDIX
Full wire-speed forwarding rate
Alarms for power and port link failure by relay output
-40°C to 75°C (-40°F to 167°F) operating temperature range
IP30 aluminium case
Supports DIN-rail mounting installation
Package Contents
IEC-2000
Quick Installation Guide
IEC-2000 Page 3
LED Status
LED Status Description
PW 1,2,3
Steady Power On
Off Power Off
FAULT
Steady Redundant Power or Ports are failed
Off Redundant Power or Ports are normal
LNK/ACT
Steady Network connection is established
Flashing Transmitting or Receiving data
Off No connection occurred
FDX/COL
Steady Full duplex mode
Flashing Collision occurred
Off Half duplex mode
1000
Steady Connection at 1000Mbps speed
Off No connection
100
Steady Connection at 100Mbps speed
Off Connection at 10Mbps speed
LFPT
Steady LFPT is enabled
Off LFPT is disabled
LFPT: Link Forward Pass Through
IEC-2000 Page 4
Power Input
Terminal Block
Power1 12 – 48VDC (+), Power Ground (-)
Power2 12 – 48VDC (+), Power Ground (-)
Earth Ground
Relay Output (Fault)
*Relay warning signal disable for following:
1. The relay contact closes if Power1 and Power2 are both failed but Power3 on.
2. The relay contact closes if Power3 is failed but Power1 and Power2 are both
on.
DC Terminal Block Power
DC Terminal Block Power Inputs: There are two pairs of power
inputs can be used to power up this media converter.
Power3: DC JACK Power input 12VDC
IEC-2000 Page 5
DIP Switch
DIP 0 (Off) 1 (On)
1 Disable LFPT Enable LFPT
2 Disable link down alarm for copper port Enable link down alarm for copper port
3 Disable link down alarm for SFP slot Enable link down alarm for SFP slot
4 Enable Force mode for SFP slot Enable Auto mode for SFP slot
Note:
LFPT: Link Forward Pass Through
Disconnect the power before change the DIP switch settings
IEC-2000 Page 6
DIN Rail Mount
Assembly: Place the switch on the DIN rail from above using the
slot. Push the front of the switch toward the mounting surface
until it audibly snaps into place
Start-up: Connect the supply voltage to start up the switch via
the terminal block (or DC JACK)
Dismantling: Pull out the lower edge and then remove the switch
from the DIN rail.
IEC-2000 Page 7
10/100Base-TX Connector
Pin Label
1 TP0+
2 TP0-
3 TP1+
4 TP2+
5 TP2-
6 TP1-
7 TP3+
8 TP3-
SFP Slot
SFP slot supports pluggable
Gigabit optic modules that
enabling you to choose from a
variety of transceiver

Other LevelOne Media Converter manuals

LevelOne FVM-1101 User manual

LevelOne

LevelOne FVM-1101 User manual

LevelOne FVT-2002 User manual

LevelOne

LevelOne FVT-2002 User manual

LevelOne VDS-0202 BNC User manual

LevelOne

LevelOne VDS-0202 BNC User manual

LevelOne IEC-1220 User manual

LevelOne

LevelOne IEC-1220 User manual

LevelOne Infinity IEC-1400 User manual

LevelOne

LevelOne Infinity IEC-1400 User manual

LevelOne VDS-0120 PSE User manual

LevelOne

LevelOne VDS-0120 PSE User manual

LevelOne VDS-1201 User manual

LevelOne

LevelOne VDS-1201 User manual

LevelOne FVT-5001 User manual

LevelOne

LevelOne FVT-5001 User manual

LevelOne IEC-1300 User manual

LevelOne

LevelOne IEC-1300 User manual

LevelOne FVT-6001 User manual

LevelOne

LevelOne FVT-6001 User manual

LevelOne GVT-2000 User manual

LevelOne

LevelOne GVT-2000 User manual

LevelOne VDS-0110 User manual

LevelOne

LevelOne VDS-0110 User manual

LevelOne FVT-2001 User manual

LevelOne

LevelOne FVT-2001 User manual

LevelOne FVT-2000 User manual

LevelOne

LevelOne FVT-2000 User manual

LevelOne POS-4000 User manual

LevelOne

LevelOne POS-4000 User manual

LevelOne VDS-1201 Operator's manual

LevelOne

LevelOne VDS-1201 Operator's manual

LevelOne FVT-0103TXFC User manual

LevelOne

LevelOne FVT-0103TXFC User manual

LevelOne Infinity IEC-2002 User manual

LevelOne

LevelOne Infinity IEC-2002 User manual

LevelOne VDS-0200 Manual

LevelOne

LevelOne VDS-0200 Manual

LevelOne GVM-1101 User manual

LevelOne

LevelOne GVM-1101 User manual

LevelOne Infinity IEC-1020 User manual

LevelOne

LevelOne Infinity IEC-1020 User manual

LevelOne POI-2001 User manual

LevelOne

LevelOne POI-2001 User manual

LevelOne Infinity IEC-1040 User manual

LevelOne

LevelOne Infinity IEC-1040 User manual

LevelOne FVT-2202 User manual

LevelOne

LevelOne FVT-2202 User manual

Popular Media Converter manuals by other brands

DirectOut Technologies ANDIAMO 2.AD Hardware guide

DirectOut Technologies

DirectOut Technologies ANDIAMO 2.AD Hardware guide

Tews Technologies TAMC900 user manual

Tews Technologies

Tews Technologies TAMC900 user manual

WFCO WF-68100-AD Series manual

WFCO

WFCO WF-68100-AD Series manual

Ltech M4-C manual

Ltech

Ltech M4-C manual

Fuba OKB 1200 user manual

Fuba

Fuba OKB 1200 user manual

DX HDV-338 user manual

DX

DX HDV-338 user manual

Dexin NDS3558A user manual

Dexin

Dexin NDS3558A user manual

Baumer HOG 16 Mounting and operating instructions

Baumer

Baumer HOG 16 Mounting and operating instructions

ASEA AC100Q-3 Operation manual

ASEA

ASEA AC100Q-3 Operation manual

San Telequip SC10EK2 W user manual

San Telequip

San Telequip SC10EK2 W user manual

Speaka Professional SP-3957148 operating instructions

Speaka Professional

Speaka Professional SP-3957148 operating instructions

GE MultiNet instruction manual

GE

GE MultiNet instruction manual

IMC Networks FiberLinX Installation and reference manual

IMC Networks

IMC Networks FiberLinX Installation and reference manual

GarrettCom Magnum FT14 Series Installation and user guide

GarrettCom

GarrettCom Magnum FT14 Series Installation and user guide

RGBlink Q2 Series quick start

RGBlink

RGBlink Q2 Series quick start

Lika C50MI quick start guide

Lika

Lika C50MI quick start guide

Sony HCD-LF10 - Cd/dvd Component For Home Theater... Service manual

Sony

Sony HCD-LF10 - Cd/dvd Component For Home Theater... Service manual

Aus Electronics Direct AA6000 user manual

Aus Electronics Direct

Aus Electronics Direct AA6000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.