FEATURES
• Conventional Toggle styling • Soft Fade ON
• Individual touch plates - simplify Dimming adjustments • Maintains DIM level when turned OFF
• Simple adjustment of DIM level - 'just a touch' • Fits standard wallbox
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
must not cause harmful interference, and (2) This device must accept any interference received, including interference
that may cause undesired operation.
INSTALLATION INSTRUCTIONS
WARNING: TO BE INSTALLEDAND/OR USED IN ACCORDANCE WITHAPPROPRIATE ELECTRICAL CODES AND
REGULATIONS.
WARNING: IF YOUARE NOT SURE ABOUTANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED
ELECTRICIAN.
CAUTION (For Incandescent Only): USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY.
CAUTION (For Magnetic Low-Voltage Only):
1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES
ONLY. USE A LEVITON ELECTRONIC LOW-VOLTAGE DIMMER TO CONTROL ELECTRONIC (SOLID STATE)
LOW-VOLTAGE TRANSFORMERS.
2. WHEN AMAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL, WITH ALL LAMPS INOPERATIVE,
EXCESS CURRENT MAY FLOW THROUGH THE TRANSFORMER. TOAVOID POSSIBLE TRANSFORMER
FAILURE DUE TO OVERCURRENT, USE ATRANSFORMER THAT INCORPORATES THERMAL PROTECTION OR A
FUSE AT THE PRIMARY WINDINGS.
OTHER CAUTIONS:
1. USE ONLY ONE (1) DIMMER PER LOAD. THE SWITCH(ES) WILL TURN THE LIGHT ON AT THE BRIGHTNESS
LEVEL SELECTED AT THE DIMMER.
2. IN A3-WAY APPLICATION, THE DIMMER MUST BE CONNECTED TO THE LOAD.
3. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS.
4. USE THIS DEVICE ONLY WITH COPPER OR COPPER
CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES
MARKED CO/ALR OR CU/AL.
MULTI-GANG INSTALLATION:
When ganging dimmers, the side sections of the mounting strap
must be removed. Use pliers to carefully bend side sections
back and forth until they break off (see Figure 1). The side
sections dissipate heat, so removing them requires a derating of
the dimmer's capacity (see chart).
MAXIMUM BULB WATTAGE (For Magnetic Low-Voltage
Only):
Low-voltage dimmers are rated in Volt-Amps (VA). The
maximum bulb wattage is determined by the efficiency of the
transformer in the low-voltage lighting system. Transformer
efficiencies will vary from different manufacturers; consider 75%
efficient as average. Use the chart to determine maximum bulb
wattage for typical transformer efficiency ratings.
TO INSTALL:
1. WARNING: TOAVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST
THAT POWER IS OFF BEFORE WIRING!
2. Remove existing wallplate and switch or dimmer, if
applicable.
3. Remove 3/4" (1.9 cm) of insulation from each circuit
conductor. Make sure that ends of conductors are straight.
4. Connect lead wires per appropriate WIRING DIAGRAM as
follows: WARNING: CONNECT A MAGNETIC LOW-
VOLTAGE DIMMER ONLY TO THE PRIMARY
(HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-VOLTAGE
TRANSFORMER. NOTE: Common terminal of a 3-Way
Switch is usually labeled and/or BLACK. Twist strands of
each lead tightly and, with circuit conductors push firmly into
appropriate wire connector. Screw connectors on clockwise
PK-92952-10-00-0A
®
For Technical Assistance Call:
1-800-824-3005 (U.S.A Only)
1 800 405-5320 (Canada Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not
for the benefit of anyone else that this product at the time of its
sale by Leviton is free of defects in materials and workmanship
under normal and proper use for two years from the purchase
date. Leviton’s only obligation is to correct such defects by
repair or replacement, at its option, if within such two year
period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton
Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591 (In Canada send to Leviton Mfg. of Canada
Ltd., 165 Hymus Blvd., Point Claire, (Quebec), Canada H9R
1E9). This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This
warranty is void if this product is installed improperly or in an
improper environment, overloaded, misused, opened, abused,
or altered in any manner, or is not used under normal operating
conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any
implied warranty is required by the applicable jurisdiction, the
duration of any such implied warranty, including merchantability
and fitness for a particular purpose, is limited to two years.
Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage
to, or loss of use of, any equipment, lost sales or profits or
delay or failure to perform this warranty obligation. The
remedies provided herein are the exclusive remedies under
this warranty, whether based on contract, tort or otherwise.
Single Pole (One location) or
3-Way (Multi-location)
120VAC, 60Hz
Incandescent
Cat. No. TGI06-10, 600W
Cat. No. TGI06-1L, 600W (Lighted)
Cat. No. TGI10-1L, 1000W (Lighted)
Magnetic Low-Voltage
Cat. No. TGM10-1L, 1000VA (Lighted)
Total minimum wattage must
exceed 40W and 40VA
INSTALLATION INSTRUCTIONS
PK-92952-10-00-0A
®
/
/
/
/
Mounting Strap
Side Sections
ON/OFF
Toggle
Upper
Touch Plate
Lower
Touch Plate
LED
(optional)
Figure 1 - Dimmer Functions
Two More than
Rating Single Gang 2 Gang
1000VA 750W 600W 525W
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Two More than
Cat. No. Single Gang 2 Gang
TGI06-10, TGI06-1L 600W 500W 400W
TGI10-1L 1000W 800W 700W
TGM10-1L 1000VA 800VA 700VA
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
/
/
//