Leviton 23A00-1 Mounting instructions

SURFACE REMOTE TEMPERATURE SENSOR
Cat. No. 23A00-1
Installation Instructions and User’s Guide
INSTALLATION ENGLISH
DI-021-EM231-00A
DESCRIPTION
The Model 23A00-1 is a surface mount temperature sensor that can be installed on an Omnistat2
thermostat to monitor the temperature of a remote location, can be combined with the onboard
temperature sensor for the average temperature of two locations, or can be used to monitor the
outdoor temperature for dual fuel heat pump installations.
When used indoors, the remote sensor allows a customer to monitor the temperature of an area without having a visible thermostat. The thermostat, or group of thermostats, could
be in a different location offering the customer complete control of temperatures.
INSTALLATION
1. Install Omnistat2 base in selected thermostat location and connect to heating/cooling equipment per manufacturer’s instructions.
2. Connect thermostat to base and con rm that everything operates correctly. Disconnect the thermostat from the base.
3. Run a twisted pair, shielded cable from the Omnistat2 to the Remote Temperature Sensor location. For distances up to 100 feet, typical twisted pair, PVC-insulated, shielded
cable may be used. For distances from 100-150 feet, twisted pair with polypropylene insulated conductors, shielded must be used. For distances from 150-250 feet, twisted pair
with foam-polyethylene insulated conductors, shielded must be used. Wire runs must not exceed 250 feet.
4.
Open cover to the Model 23A00-1 Remote Temperature Sensor. Connect the data wires of the shielded cable to the wires on the temperature sensor using the supplied wire splices.
5. Wrap the shield around the jacket of the cable and tape.
6. At the Omnistat2 location, make the connections to the Green and Black terminals under the section marked “Remote Temp Sensor” on the right terminal strip. Note that the
shield and one of the wires from the remote temperature sensor are tied together and get connected to the Black terminal – See Figure 1.
CONFIGURATION
Reconnect the Omnistat2 to the base and con gure the remote temperature sensor according to the application.
The Temperature Sensor Installation Settings are used to con gure the internal temperature sensor and optional remote temperature sensor that is connected to the thermostat.
Any temperature sensors that are set as the same type (i.e. indoor or outdoor) will display the average temperature reading among the sensors. An asterisk (*) next to a setup item
indicates the default setting.
Internal Sensor: This will enable or disable the onboard temperature sensor for indoor use only. *Enabled
External Sensor 1: This will enable the external temperature sensor for indoor or outdoor use. All indoor and outdoor temperatures are averaged between all sensors of the same
type. *Disabled
OPERATION
On the Omnistat2 Home Page, con rm that the thermostat is displaying the proper temperature. If the remote temperature sensor is con gured as “outdoor’, con rm that the proper
outdoor temperature is displayed in the Message Bar on the Omnistat2.
SPECIFICATIONS
DIMENSIONS: 2W x 1.5H x 1D
WARNINGS AND CAUTIONS
• Read and understand all instructions. Follow all warnings and instructions marked on the product.
• Do not use this product near water - e.g., near a tub, wash basin, kitchen sink or laundry tub, in a
wet basement, or near a swimming pool.
• Never push objects of any kind into this product through openings, as they may touch dangerous
voltages.
• SAVE THESE INSTRUCTIONS.
WARNINGS AND CAUTIONS
• Never install communications wiring or components during a lightning storm.
• Never install communications components in wet locations unless the
components are designed speci cally for use in wet locations.
• Never touch uninsulated wires or terminals unless the wiring has been
disconnected at the network interface.
• Use caution when installing or modifying communications wiring or
components.
(23I00-1)
FIGURE 1: OVERALL INSTALLATION DIAGRAM
WEB VERSION

For Technical Assistance Call: 800-824-3005 - www.leviton.com
DI-021-EM231-00A (23I00-1)© 2013 Leviton Mfg. Co., Inc.
LEVITON LIMITED WARRANTY
Leviton warrants to the original consumer purchaser and not for the benet of anyone else that products manufactured by Leviton under the Leviton brand name (“Product”) will be free from defects in
material and workmanship for the time periods indicated below, whichever is shorter: • OmniPro II and Lumina Pro: three (3) years from installation or 42 months from manufacture date.
• OmniLT, Omni IIe, and Lumina: two (2) years from installation or 30 months from manufacture date. • Thermostats, Accessories: two (2) years from installation or 30 months from manufacture date.
• Batteries: Rechargeable batteries in products are warranted for ninety (90) days from date of purchase. Note: Primary (non-rechargeable) batteries shipped in products are not warranted.
Products with Windows® Operating Systems: During the warranty period, Leviton will restore corrupted operating systems to factory default at no charge, provided that the product has been used as
originally intended. Installation of non-Leviton software or modication of the operating system voids this warranty. Leviton’s obligation under this Limited Warranty is limited to the repair or replacement,
at Leviton’s option, of Product that fails due to defect in material or workmanship. Leviton reserves the right to replace product under this Limited Warranty with new or remanufactured product.
Leviton will not be responsible for labor costs of removal or reinstallation of Product. The repaired or replaced product is then warranted under the terms of this Limited Warranty for the remainder of
the Limited Warranty time period or ninety (90) days, whichever is longer. This Limited Warranty does not cover PC-based software products. Leviton is not responsible for conditions or applications
beyond Leviton’s control. Leviton is not responsible for issues related to improper installation, including failure to follow written Installation and operation instructions, normal wear and
tear, catastrophe, fault or negligence of the user or other problems external to the Product. To view complete warranty and instructions for returning product, please visit us at www.leviton.com.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their
respective owners; such use is not meant to imply afliation, sponsorship, or endorsement.
WEB VERSION
Table of contents