LG 14HK701G-W User manual

2
ENGLISH
CONTENTS
OPEN SOURCE SOFTWARE NOTICE
INFORMATION --------------------------------------------3
ON CLEANING ---------------------------------------------3
GENERAL DESCRIPTION---------------------------------3
PART NAME AND FUNCTION ---------------------------6
ASSEMBLING BATTERY--------------------------------11
REMOVING BATTERY ----------------------------------12
SPECIFICATION AND DIMENSION OF EACH PART
-------------------------------------------------------------13
ENVIRONMENTAL REQUIREMENT------------------- 20
CALIBRATION SOFTWARE INSTALL -----------------20
CONNECTION TYPES ----------------------------------- 21

3
ENGLISH
OPEN SOURCE SOFTWARE NOTICE
INFORMATION
To obtain the source code under GPL, LGPL, MPL, and other open source licenses, that is contained in this
product, please visit http://opensource.lge.com.
In addition to the source code, all referred license terms, warranty disclaimers and copyright notices are
available for download.
LG Electronics will also provide open source code to you on CD-ROM for a charge covering the cost of performing
such distribution (such as the cost of media, shipping, and handling) upon email request to opensource@lge.
com.
This offer is valid for a period of three years after our last shipment of this product. This offer is valid to anyone
in receipt of this information.
ON CLEANING
Recommended Cleaning Chemicals
•Isopropanol 70%
•Ethanol 70%
•Cidex®OPA
•0.9% NaCl solution
How to Use Cleaner
•Prior to cleaning, turn off the Detector and remove the power cable.
•Soak a soft cloth in a recommended cleaner, then lightly rub the screen with no more than 1 N of force.
•The cleaner could cause serious damage if it leaks inside the Detector while cleaning.
•Do not use benzene, thinner, acids or alkaline cleaners or other such solvents.
•Cleaning guidelines for Detector must only be carried out by medical professionals (doctors or nurses) and
must not be handled by patients.
GENERAL DESCRIPTION
Overview
This model is an x-ray imaging device, a system that can acquire and process X-ray images as digital images. It
utilizes amorphous silicon and a high-performance scintillator to ensure sharp high-definition image quality
with the resolution of 3.6 lp/mm and the pixel pitches of 140 um. This device is a flat panel based X-ray image
acquisition device.This device must be used in conjunction with an operating PC and an X-ray Generator. This
device can be used for digitizing and transferring X-ray images for radiological diagnosis.The data transmission
between the Detector and PC can be enabled with a wired (cable) or wireless connection.
Product Component
•Detector:
•Control Box:
-AC power cord for Control Box
•Battery Charger:
•2 Battery ( )
•AC Power adapter for Charger ( )
•AC Power cord for AC Power adapter
•Cable
-Main Cable: Detector and Control Box link cable (Supply DC power, Ethernet data, control signals of X-ray
Generator)
-Trigger Cable: X-ray Generator to Control Box, transmit control signal between Detector and X-ray
Generator. (Optional)
-LAN Cable: Control Box to PC, exchanges Ethernet data between PC and Detector. (Optional)
•CD: Owner's Manual,
•Regulatory Manual, Inspection Report

4
ENGLISH
Basic Accessories
100kg
Detector 1 EA Battery 2 EA AC Power cord for AC Power adapter 1 EA Inspection Report 1 EA
CD (Owner's Manual / ) 1 EA Main Cable 1 EA Regulatory Manual 1 EA AC Power adapter for Charger 1 EA
Charger 1 EA Control Box 1 EA AC Power cord for Control Box 1 EA

5
ENGLISH
Optional Accessories
Trigger Cable 1 EA LAN Cable 1 EA
•Some models may not include additional accessories.
CAUTION
•You must use the authorized components as per the specification below. Unauthorized components may cause damage and/or cause the product to malfunction.
Component Standard
LAN Cable More than CAT5E Standard
Power Cord US – Approved Medical grade regulation
Others – Approved country safety regulation
•The AC/DC adapters etc. that are being used, with the exception of the upper components, must be supplied by the manufacturer.

6
ENGLISH
PART NAME AND FUNCTION
Detector
Front Back
100kg
1

7
ENGLISH
Side
3
2
4
1
Battery
2
Power Button: Power on/off switch
(On: press over 1 Sec, Off: press over 5 Sec)
3
LED Indicator: Indicating Detector’s status
4
Connection to Main Cable
LED LED Color Status
Green Battery is more than 30 % charged.
Orange Battery charging status is 10 ~ 30 %.
Orange Blinking Battery is less than 10 % charged.
Green Ethernet/Wireless(Station) connection
Green Blinking Wireless(Station) disconnected
White Wireless(AP) connection
White Blinking Wireless(AP) disconnected
Off Ethernet disconnected
Green Power On
Green Blinking Sleep mode
Off Power Off

8
ENGLISH
Battery and Charger
NOTE
•Battery: Li-ion polymer battery (Charging time -Typ. 4 hours)
•Battery pack itself shows the remaining battery percentage.
•Battery charger: 3 ports cradle type
•LED Indicator: Following LEDs are located to each battery.
LED Indicator Status
Green Completion of charging
Orange On charging
Orange Blinking Error (Connection error, etc)
Battery Remain Indicator Battery Level
75 ~ 100%
50 ~ 75%
25 ~ 50%
0 ~ 25%

9
ENGLISH
Control Box
AC-IN T4L 250V
Ethernet Sync
DXD 1 DXD 2
Power Ethernet Ready Exposure
1
AC-IN T4L 250V
Ethernet Sync
DXD 1 DXD 2
Power Ethernet Ready Exposure
7
5
2 3
6
4
No. LED Indicator LED Color Status
1
Green Power normal operation
Off Power off (AC power cord no connection or Power error)
Green Ethernet normal operation
Green blink On data communication
Off Ethernet disconnected
Green Ready signal from X-ray Generator is active
Off Ready signal from X-ray Generator is inactive
Orange blink Power error
Orange Exposure signal from X-ray Generator is active
Off Exposure signal from X-ray Generator is inactive
Orange blink Power error

10
ENGLISH
No. LED Indicator Status
2
Connecting the Control Box and the Detector A. This connector supply power (24V 2.1 A) to the Detector, transmits X-ray synchronization signals and Ethernet image data.
3
Connecting the Control Box and the Detector B.This connector supply power (24 V 2.1 A) to the Detector, transmits X-ray synchronization signals and Ethernet image data.
Control Box supports 2 Detector connections. Usage is, one is for Bucky stand, the other is for table (bed). Generally, X-ray room of hospital installs 2 Detectors, Bucky stand and
table type, it's far more convenient and efficient working environment. These 2 Detectors are not operated simultaneously, control box selects the operating Detector by AWS
command.
4
Connects AC power cord.
5
Ethernet port to transmit image/command between the Detector and PC.
6
This is to synchronize the Detector and X-ray Generator.
7
Control box power fuses are 4A, 250V to Type T fuse.
Power rating:

11
ENGLISH
ASSEMBLING BATTERY
1 Check the battery mounting hole direction. 2 Insert into the hole on the side with the indicator. 3 Press the opposite side to secure the battery indicator.

12
ENGLISH
REMOVING BATTERY
1 Push the battery lock button in the direction of the picture. 2 Remove the battery by lifting it in the direction of the picture.

13
ENGLISH
SPECIFICATION AND DIMENSION OF EACH
PART
The product specifications are subject to change without prior notice for product improvements.
~ refers to alternating current (AC), refers to direct current (DC).
Specifications
Detector
Item Specification
Model 14HK701G
Sensor type Amorphous Silicon TFT
Scintillator Type CsI:TI
Total Pixel Matrix 2500 x 3052 pixels
Total Pixel Area 350 x 427.28 mm
Pixel Pitch 140 um
Effective Pixel Matrix 2488 x 3040 pixels
A/D Conversion 16 bits
Data transmission 802.11 a/b/g/n/ac Wireless LAN Standard, 150 Mbps
Wired Gigabit Ethernet Standard, 500 Mbps
Cycle time Typ. 8 Sec (Wired)
Typ. 11 Sec (Wireless)
Image Transmission Typ. 2 Sec (Wired)
Typ. 2.5 Sec (Wireless)
Image Storage Stores up to 200 images
Energy range 40 kVp ~ 150 kVp
MTF Typ. 89 % at 0.5 lp/mm
DQE Typ. 72 % at 0.1 lp/mm
Item Specification
Size (Width x Height x Depth) 384.0 x 460.0 x 15.2 mm
Weight Typ. 2.95 kg
Window material Carbon Fiber
Trigger mode Manual Mode
Auto Mode (Auto Exposure Detection)
Power consumption Typ. 28 W
Wireless Standard:
802.11 a/b/g/n/ac compliance
Peak mode: 867 Mbps
Frequency: 2.4 GHz / 5 GHz
Bandwidth: 20 MHz / 40 MHz / 80 MHz
MIMO: 2X2
Rating 24 V 2.1 A
Applied part Type: BF
Location:The front side of the Detector (Effective area only)
NOTE
•Maximum wireless signal rate derived from IEEE standard specifications. Actual data throughput will vary.
Network conditions and environmental factors, including volume of network traffic, building materials and
construction, and network overhead, lower actual data throughput rate.
•Recommended Maximum operable distance: 2 m (From the Access Point)
•Wireless antennas:The module adopts the latest 802.11ac technology. The transmitter of the module is
powered by host equipment (Detector). The antennas are 2 printed-dipole antennas.
•Wireless module: 802.11 a/b/g/n/ac USB2.0 module is implemented. It supports 2T2R (2 transmit 2 receive)
MIMO technology, which delivers throughput up to 300 Mbps.
•Images can be saved by the X-ray generator while the power of the detector is turned on without connecting
to a PC.To produce images, X-ray is irradiated at intervals of more than 10 seconds. Check and load the saved
images from .

14
ENGLISH
Detector has been tested with below table’s X-ray condition. This table is only for reference.The legally certified
radiologist expert should control X-ray dose.
Adult
SID (inch/cm) Tube Voltage (KV) Tube Current (mA) Tube Current xTime
(mAs)
Chest P-A 72 inch / 182.8 cm 120 KV 250 mA 2.5 mAs
C-spine LAT 72 inch / 182.8 cm 70 KV 200 mA 10 mAs
L-spine A-P 40 inch / 101.6 cm 75 KV 320 mA 20 mAs
Abdomen A-P 40 inch / 101.6 cm 75 KV 320 mA 10 mAs
Pelvic A-P 40 inch / 101.6 cm 70 KV 320 mA 16 mAs
Wrist A-P 40 inch / 101.6 cm 55 KV 100 mA 2.5 mAs
Elbow A-P 40 inch / 101.6 cm 55 KV 100 mA 3.2 mAs
Shoulder AP 40 inch / 101.6 cm 70 KV 200 mA 6.4 mAs
Foot A-P 40 inch / 101.6 cm 58 KV 100 mA 2.5 mAs
Ankle A-P 40 inch / 101.6 cm 59 KV 100 mA 3.2 mAs
Knee A-P 40 inch / 101.6 cm 58 KV 100 mA 6.4 mAs
Regarding paediatric dosage, it should be much less than for an adult.The certified radiologist should pay
special attention to paediatric X-ray dosage levels.
GRID
Item Recommended Specification
SID 100 cm / 130 cm / 150 cm / 180 cm
Size 384 x 460 mm
Ratio 10 : 1
Frequency 215 Line / Inch
Inter Spacer AL
Battery
Item Specification
Model
Size (Width x Height x Depth) 204.6 x 110.5 x 7.8 mm
Weight Typ. 0.24 kg
Output Nominal voltage Typ. 7.5 V
Operation Temp 10 °C ~ 35 °C
Charging time 4 hours (standard) when charging with the Detector.
3 hours (standard) when charging two batteries with the charger.
Capacity Typ. 4000 mAh, Min. 3850 mAh
Battery performance Typ. 260 shots/6.5 hours
Min. 160 shots/4 hours (Cycle time 90 Sec, with Full charged battery)

15
ENGLISH
Battery Charger
Item Specification
Model
Size (Width x Height x Depth) 125.0 x 90.0 x 255.0 mm
Weight Typ. 0.9 kg
Input 19 V 3.42 A
Output Nominal voltage 8.7 V
Battery Charger Adapter
Item Spec
Model
Manufacturer Asian Power Devices Inc. (APD)
Size (Width x Height x Depth) 134.0 x 59.8 x 31 mm
Weight Typ. 0.3 kg
Input AC 100-240V~ 50-60 Hz, 1.5 A-0.7 A
Output 19 V 3.42 A
Classification by protection type
against Electric Shock
Class equipment
Cable length 1.5 m
Control Box
Item Specification
Model
Size (Width x Height x Depth) 125.0 x 109.8 x 255.0 mm
Weight Typ. 1.3 kg
Input AC 100-240V~ 50/60 Hz, 1.4-0.7 A
Output
24 V 2.1A, Trigger signals, Ethernet data for Detector A.
24 V 2.1A, Trigger signals, Ethernet data for Detector B.
Control Box supports 2 Detector connection.
Usage is, one is for Bucky stand, the other is for table (bed).
Generally, X-ray room of hospital installs 2 Detectors, Bucky stand and
table type, it's far more convenient and efficient working environment.
These 2 Detectors are not operated simultaneously, control box selects
the operating Detector by AWS command.
Transmission image/command between the Detector and PC.
Transmission control signals between the Detector and X-ray Generator.

16
ENGLISH
Cables
Item Length Qty
Main Cable 7 m 1
LAN cable (Optional) 10 m 1
Power cord (110V or 220V) 1.5 m 2
Trigger Cable (Optional) 15 m 1
Wireless module (LGSWFAC73) Specifications
Wireless LAN (IEEE 802.11a/b/g/n/ac)
Frequency Range Output power (Max.)
2400 to 2483.5 MHz
5150 to 5725 MHz
5725 to 5850 MHz (Not for EU)
18.1 dBm
18.6 dBm
13.8 dBm
•As band channels can vary per country, the user cannot change or adjust the operating frequency. This
product is configured for the regional frequency table.
•* IEEE 802.11ac is not available in all countries.

17
ENGLISH
Dimension
Detector
Unit: mm
Front Side
100kg
100kg
384.0
460.0
100kg
15.2

18
ENGLISH
Control Box
Unit: mm
Front Side
Power Ethernet Ready Exposure
125.0
Power Ethernet Ready Exposure
255
109.8

19
ENGLISH
Battery
Unit: mm
Front Side
204.6
110.5
7.8
Battery Charger
Unit: mm
Front Side
125.0
90.0
255.0

20
ENGLISH
ENVIRONMENTAL REQUIREMENT
PC System requirement
PC Specification
CPU Intel i5
Memory 4 GB
Disk capacity At least 10 GB ~ 500 GB recommended
Network card Dual Ethernet 100/1000 Mbps
OS Windows 7/8.1/10 (32bit, 64bit)
Monitor Min. Resolution 1280x720
AP Cisco models recommended (e.g. Linksys EA9200)
CALIBRATION SOFTWARE INSTALL
How to install
Run the installation file. Once the installation file has been executed, follow the
installation instructions on the screen.
How to delete
You can delete the in the following ways:
Deleting from the Control Panel
1 Select Control Panel from the Start menu.
2 Select Programs and Features in Control Panel.
3 Select the [LG DXD Calibration] on the lists.
4 When the program installation and deletion screen appears on the screen, select the [Delete] button.
5 Follow the deletion instructions on the screen and click the [Next] button to proceed.
Deleting with the installation file
1 Run the installation file, then follow the deletion instructions on the screen.
NOTE
•When using the installation file to delete the program, the Installation file must be the same version as the
current software.
Table of contents
Other LG Security Sensor manuals
Popular Security Sensor manuals by other brands

Interlogix
Interlogix ACL870SU-BSMF installation manual

INIM Electronics
INIM Electronics ODI100H Installation and programming manual

Menlo Systems
Menlo Systems FPD510 operating manual

Optex
Optex inSight INS-HX-80N installation instructions

green-i
green-i SPIR-F Product guide

Orno
Orno OR-CR-220 Operation and installation instruction