1. Safety 3
2. Before & After Installation 4
3. Electrical Installation 5
4. Mechanical Installation 6
5. Product Specifications 8
6. Disclaimer of Liability / Disposal 10
7. Transporting and Storage 10
8. Appendix. 11
Revisions Table
Date
Version
Description of change
Remark
2016.12.20 1.0 (1st edition) Publish Installation Manual
2017.08.14 2.0 Change M/Load Spec.

3
Safety
The instructions related to the safety indicated in
the following are for preventing unexpected danger
or damage in advance by safely and exactly using
the product.
Non-compliance of the instructions may immedia-
tely cause serious injury or death.
Non-compliance of the instructions may cause
death or serious injury to the user.
Non-compliance of the instructions may cause
injury or property damage to the user.
①Do not contact with electrically active parts of
the panel, such as terminals, regardless of
connection of the module. It may result in spark
or lethal electric shock.
②Please don’t use the module with the broken
window or the torn back side. There is a danger
of electric shock.
① ②
①Please perform works in the dry condition and
use only dry tools. Do not handle the wet panels
without protection equipment. It may result in
safety accident.
②Damaged module must be treated with safety
protection equipment. It may result in injury.
③Do not approach the damaged or broken module
unless you are an expert. It may result in serious
injury.
④No electrical parts like cables are located after
installation between laminate and mounting
structure.
⑤Do Not reconnect or repair Junction box Cable.
It may occur spark or electric shock.
⑥Do not bending junction box's cable. While
under stress, it may occur module damage.
Cable bending radius should be more than
4 times the cable diameter, at least.
①Please use proper equipment, connector, wire
and buttress for system configuration of the
module. It may result in damage or failure of the
product.
②Do not perform installation in rainy, heavily
windy or snowy days. It may result in safety
accident.
③Do not make holes in the frame or glass of the
module. It may decrease the strength of the
frame or break the glass.
④Do not touch the glass surface or frame of the
solar module after installation of the module. It
may result in injury.
⑤Do not locate a heavy object onto the module.
Do not stand on or step on the module. Do not
drop or suddenly lay down the module. It may
result in injury.
⑥Do not scratch the coating surface of the frame.
It may decrease the strength due to corrosion of
the frame.
⑦Do not concentrate sunlight on the module
surface. It may result in damage of the product.
⑧Do not apply a shock to the junction box of the
module or pull the cable. Do not remove the
labels attached to the module. It may result in
damage of the product.
⑨If the installing structure has a curved surface
e.g. arch type as shown in the below picture, do
not forcefully modify the module in installation
when connecting it with the structure. Please
install the module in the place where the structure
has been completely set up because deformation
of the structure may cause deformation of the
product when performing installation by using a
crane, etc after assembling the module to the
installing structure.
① ② ③
④ ⑤ ⑥
⑦ ⑧
⑨

4
Before & After Installation
Before Installation
Please carefully read this manual before
installation.
• Solar module installation should be performed by
an authorized installer for the safety and
maintenance of the system.
• All installation instructions should be clearly
understood before attempting installation.
• Do not twist, pull, or scratch the cable attached to
the solar module.
• Do not touch the solar module with bare hands. It
may result in a burn or injury.
• Do not drop the solar module and cause an
excessive load on solar module.
• Do not disassemble the solar module.
• After installation or repair, check whether solar
module operates properly or not.
• In case the currently used solar module or the
parts applied to the solar module have been
replaced, check whether the changed solar
module is properly operated or not. The newly
replaced solar module and its parts must be the
same solar module (module name) and parts with
the current solar module.
• Please contact the local office to confirm the
regulations and to obtain permission.
• Do not let anyone approach the solar module
who has little knowledge of solar modules or on
the measures to take when solar modules are
damaged in order to avoid the risk of injury or
electrical shock.
• Do not locate the solar module horizontally, as
this may cause dirt or white efflorescence (glass
deformation)
• Panels produce voltage even when not
connected to an electrical circuit or load.
• Panels are intended for outdoors, land based
applications only. Panels are not intended for use
indoor use or application on moving vehicles of
any kind.
• Reflection from external environments such as
snow, water or other surfaces can increase the
power generated by the panel.
• Industry standard rated specifications are made
at conditions of 1000W/m2 irradiance and 25°C
(77ºF) solar cell temperature. Colder temperatur-
es can substantially increase voltage and power.
• Keep the solar module and system away from
children when installing.
• Keep the module packed in the carton until the
time of installation.
• Make sure flammable gases are not generated
near the installation site.
• Do not work alone. Please work as part of a team
of two or more people.
• Wear a safety belt if working high above the
ground.
• Contact with electrically active parts of the panels,
such as terminals, can result in burns, sparks and
lethal shock whether the panel is connected or
disconnected.
• Even partial shadowing can substantially reduce
panel and system output.
• Care must be taken to avoid low tilt angles which
may cause dirt to buildup on the glass against the
frame edge.
• Dirt build-up on the surface of the panel can
cause active solar cells to be shaded and
electrical performance to be impaired.
• Always keep the back surface of the panel free
from any foreign objects or structural elements
which could come into contact with the panel,
especially when the panel is under mechanical
load.
• For permission to use mounting methods not
described in the Mounting Guide please consult
LG Solar. Failure to do so will void the warranty
and panel certification.
After Installation
•
Plug the connector in tightly and ensure that the
wiring properly works.
• It is advisable to conduct periodic inspection of
the panels for damage to front glass, back sheet,
frame, junction box, or external electrical
connections.
• Check electrical connections for loose connec-
tions and corrosion.
• PV panels can operate effectively without ever
being washed, although removal of dirt from the
front glass can increase output.
• Water, ethanol or a conventional glass cleanser
with a micro-fiber cloth can be used for regular
washing or rinsing of the front glass to remove
dust, dirt or other deposits.
• No aggressive and abrasive cleansers or
chemicals such as alkali chemicals including
ammonia based solution should ever be used on
the treated front glass.
• Always wear rubber gloves for electrical
insulation while maintaining, washing or cleaning
panels.
• Deposits of foreign material on the frame surface
can be cleaned using a wet sponge or cloth and
dried in air or by using a clean chamois.
• Perform the wiring work by connecting the
connector and wires to the stand away from the
roof or ground.

5
E
l
ec
t
r
i
ca
l
In
s
t
a
ll
a
t
io
n
Caution
• Avoid all electrical hazards when installing, wiring,
operating and maintaining a panel.
• Do not use panels of different electrical or
+ - + -
+ - + -
…………..
physical configurations in the same system. + -
• Match the polarities of cables and terminals when
making the connections; failure to do so may
result in damage to the panel.
• When reverse currents can exceed the value
marked on the name plate, a properly rated and
certified over-current device (fuse or circuit
breaker) must be connected in series with each
panel or string of panels.
• The rating of the over-current device shall not
exceed the maximum series fuse rating marked
on the name plate.
• The panel contains factory installed bypass
diodes located inside the junction box.
• When installing the system, it is recommended to
install the lightning rod to protect the system.
• The junction box should not be opened. Opening
the junction box may void the warranty.
• Panels with a suspected electrical problem
should be returned to LG Electronics for
inspection and possible repair or replacement as
per the warranty conditions provided by LG
Electronics.
Electrical Connections
• Modules may be connected in series and/or
parallel to achieve the desired electrical output as
long as certain requirements are met.
• Please use only the same type of modules in a
combined source circuit.
• Do not disconnect the module under load.
Shock hazard can occur near the solar modules
connection means.
Series Connection
• The solar modules may be wired in series to
produce the desired voltage output.
• The current of each module connected in series
should be same.
• The maximum number of series connected
modules can be determined by basis on max.
system voltage, the 125% safety factor, and the
module Voc which can be checked in “Product
Specifications” in this document.
Series connection for more voltage
Parallel Connection
• The solar modules may be combined in parallel
to produce the desired current output.
• When modules are combined in parallel, the total
current is equal to the sum of currents from each
module.
• The voltage of each module connected in parallel
should be same.
• When connecting plural strings of modules in
parallel every series string or solar module must
be fused prior to combining with other strings.
By pass diodes are factory installed in the solar
modules.
• Please refer to the applicable regional and local
codes for additional fusing requirements and
limitations on the maximum number of solar
modules in parallel.
• Maximum parallel strings without proper
measures, e.g. fuse 20A and/or blocking diode :
1 string
Parallel configuration is not limited if proper
measures are taken to block the reverse current
flow, e.g. fuses for the protection of the module
and cables from over-current and/or blocking
diodes for prevention of unbalanced string
voltage.
• A multiplying factor is required for increased
output of the PV modules. Under normal
conditions, a PV module is likely to experience
conditions that produce more current and/or
voltage than reported at standard test conditions.
Accordingly, the values of Isc and Voc marked on
this PV module should be multiplied by a factor of
125% when determining component voltage
ratings, conductor ampacities, fuse sizes, and
size of controls to the PV output.
• Depending on national directives additional
safety factors might be applicable for overcurrent
protection.
• Do not exceed 80% of maximum system voltage.
• The maximum solar module configuration can be
found in “Product Specifications”.
+ - + - + - + -
…………..
+
-
Parallel connection for more current

E
l
ec
t
r
i
ca
l
In
s
t
a
ll
a
t
io
n
M
ec
h
a
ni
ca
l
In
s
t
a
ll
a
t
io
n
General Wiring
•LG Electronics recommends that all wiring be
double insulated with a minimum rating of 90°C
(194°F).
•All wiring should use a flexible copper (Cu)
conductor.
•The minimum size should be determined by the
applicable codes.
•We recommend a size not smaller than 4mm
2
.
Earth Grounding
•The solar modules from LG Electronics meet the
conditions of safety class II. Therefore grounding is
not mandatory. However grounding is
recommended. Also equipotential bonding must be
realized. The national directives must be respected.
•Specific information on the solar module
dimensions and location of grounding holes is
provided in ‘Product Specifications’.
•One M4 stainless steel bolt, one nut, one spring
washer, two flat washers, one cup washer, one
star washer and 12 AWG Cu wires are
recommended per solar module.
•There is an earth hole in the center of the module
frame. Using this hole, an earth conductor and the
solar module frame may be recommended to
connected and earthed as the below drawing.
• To prevent electric shock and fire, a protective
ground must be done on the frames of solar
modules and arrays although the solar modules
from LG meet the conditions of safety class Ⅱ.
The national directives must be respected.
Module frame
Bolt
Flat washer
Star washer
Cup washer
Grounding wire
Flat washer
Spring washer
Nut
Module Mounting
• The LG Electronics’ (LGE) Limited Warranty for
solar modules is contingent upon modules being
mounted in accordance with the requirements
described in this section.
• The solar modules are in Application Class A and
have the Safety Class II. Therefore they can be
operated in systems with 120 V DC and higher.
General access is not restricted.
Site Consideration
LGE solar modules should be mounted in a loca-
tion that meets the following requirements.
Operating Temperature
• Maximum Operating Temperature: +90°C (194°F)
• Minimum Operating Temperature: -40°C (-40°F)
Excluded Operating Environments
• The solar modules from LG Electronics can be
operated in a location where they could come in
contact with salt water or ammonia, if they have
been tested successfully for these operating
conditions. Please see related certificates. Please
get a release from LG Electronics for increased
conditions.
Design Strength
• Snow loads(Front side, 60Cell) : 6000 Pascal
• Wind loads(Rear side, 60Cell) : 5400 Pascal
• Snow loads(Front side, 72Cell) : 5400 Pascal
• Wind loads(Rear side, 72Cell) : 4300 Pascal
①
②
①
②
②
①
②
①
60Cell
① : 200mm
② : 300mm
72Cell
① : 300mm
※
This mounting method
is by
using frame bolt
holes.
※
The mounting rails must
run
perpendicularly
to the
module
long
side.
• Use corrosion resistant material mounting rails
and hardware.
• Use appropriate bolted connections as per
manufacturer’s instructions.
• No electrical parts like cables are located after
installation between laminate and mounting
structure.
Mounting
Rails
6

M
ec
h
a
ni
ca
l
In
s
t
a
ll
a
t
io
n
7
Mounting Methods
General Information
• Select the appropriate orientation to maximize
sunlight exposure.
• In order to prevent water from entering the
junction box, which could present a safety hazard,
module should not be mounted such that the
front/top glass faces downward.
• Clearance between the solar module frames and
structures such as roofs or ground is required to
prevent wiring damage and to allow air to
circulate behind the solar module. The
recommended standoff height is a minimum of
100mm.
• When installed on a roof, the solar module must
be mounted over a fire-resistant roof covering
rated for the application. The fire resistance of the
solar module from LG Electronics is class C after
ANSI/UL790.
• The solar module is only IEC listed for use when
its factory frame is fully intact.
• Do not remove or alter the solar module frame.
• Creating additional mounting holes may damage
the solar module and reduce the strength of the
frame.
• A 6mm gap between module frames should be
allowed to avoid tension from thermal expansion.
• The solar module may be mounted using the
following methods: (*Torque:8~12Nm )
• When installing modules in heavy snow areas,
special care should be taken to install the
modules in a manner that provides sufficient
design strength while meeting local code
requirements.
Mounting by using frame bolts holes
• Secure the solar module to the structure using
the factory mounting holes.
• Four M8 stainless steel bolts, four nuts, four
spring washers, and eight flat washers are
recommended per solar module.
• The module may be fastened to a support using
both the outer and inner bolt holes of the frame.
• Each module should be securely fastened at a
minimum 4 points on two opposite sides.
• Specific information on the solar module
dimensions and location of mounting holes is
provided in ‘Product Specifications’.
• Tighten the bolt securely using this combination.
Place spring washer between Flat washer and
Nut.
Module frame
Nut
Spring washer
Flat washer
Mounting Rail
Flat washer
Bolt
* Mounting Rails Material : Aluminum, Stainless steel, etc.
→ We recommend more than 40x40mm mounting rails.
Mounting by using clip or clamps
• The module may be fastened to a support using
clips or clamps on both the long edge and the
short edge of the modules.
• Specific information on location of clamping
is provided in ‘Mechanical Installation Scene’
(Refer Appendix.).
• The module frame must overlap more than 15mm.

8
P
r
odu
c
t
S
p
ec
i
f
i
ca
t
ion
s
Rated electrical characteristic except power rating within -0/+3 percent
are
within
10
percent
of measured.
Values
at
Standard Test Condition (STC)
:
Irradiance 1000W/m
2
,
Cell
temp. 25
℃
,
1.5AM
Certificates
Electrical Properties
Mechanical Properties
M
odule Series
M
odel Name
IEC612
15 Ed.2, IEC 61730,
S
afety Class II, CE, ISO9001
Pm
ax at STC
Po
wer Tolerance
Voc
at STC
Isc
at STC
V
mpp at STC
I
mpp at STC
M
ax. No. of modules in series
Max. Series Fuse
Rating
M
ax. System Voltage
Conne
ctor
L
ength
W
idth
H
eight
We
ight
W
%
V
A
V
A
A
V
mm
mm
mm
kg
LGXXXN1T-A5
LG300N1T-A5
Yes
300
0~3%
40.5
10.04
32.1
9.36
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG305N1T-A5
Yes
305
0~3%
40.6
10.04
32.6
9.37
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG310N1T-A5
Yes
310
0~3%
40.7
10.08
33.1
9.38
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG315N1T-A5
Yes
315
0~3%
40.8
10.12
33.5
9.41
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG320N1T-A5
Yes
320
0~3%
40.9
10.16
33.9
9.45
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG325N1T-A5
Yes
325
0~3%
41.0
10.20
34.3
9.48
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG330N1T-A5
Yes
330
0~3%
41.1
10.24
34.7
9.52
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG335N1T-A5
Yes
335
0~3%
41.2
10.28
35.1
9.55
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG340N1T-A5
Yes
340
0~3%
41.3
10.32
35.5
9.59
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LG345N1T-A5
Yes
345
0~3%
41.4
10.36
35.9
9.62
19
20
1000
MC4/PV-JM601A
1730
1024
40
18.2
LGXXXN2T-A5
LG360N2T-A5
Yes
360
0~3%
48.6
9.91
38.8
9.29
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG365N2T-A5
Yes
365
0~3%
48.7
9.95
39.3
9.30
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG370N2T-A5
Yes
370
0~3%
48.8
9.99
39.7
9.33
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG375N2T-A5
Yes
375
0~3%
48.9
10.03
40.2
9.34
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG380N2T-A5
Yes
380
0~3%
49.0
10.07
40.6
9.37
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG385N2T-A5
Yes
385
0~3%
49.1
10.11
41.0
9.40
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG390N2T-A5
Yes
390
0~3%
49.2
10.15
41.4
9.43
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG395N2T-A5
Yes
395
0~3%
49.3
10.19
41.8
9.46
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG400N2T-A5
Yes
400
0~3%
49.4
10.23
42.2
9.49
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG405N2T-A5
Yes
405
0~3%
49.5
10.27
42.6
9.51
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG410N2T-A5
Yes
410
0~3%
49.6
10.31
43.0
9.54
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
LG415N2T-A5
Yes
415
0~3%
49.7
10.35
43.4
9.57
16
20
1000
MC4/PV-JM601A
2064
1024
40
22.0
Note) MC4 formal name : PV-KST4 / 6II-UR, PV-KBT4 / 6II-UR

9
P
r
odu
c
t
S
p
ec
i
f
i
ca
t
ion
s
- Dimensions of Modules
60Cell Module
Unit : mm
72Cell Module

10
Disclaimer of Liability / Disposal
Disclaimer of Liability
• Since the use of this Safety, Installation and
Operation instruction s and the conditions or
method s of installation, operation , use and
maintenance of the pan el are beyond the control of
LG Electronics, LG Electronics doe s not assume
responsibility and expressly disclaims liability for
loss, damage, injury or expense arising out of or in
any connected with such installation , operation ,
use or maintenance of the pane l.
• LG Elec tron ics assumes no responsibility f or any
infringement of patents or other rights of third
parties that may result from use of the pane l. No
license is granted by implicationor otherwise under
any patent or patent rights.
Disposal of your old appliance
1. This c rossed-out
wheeled bin symbo l
i
nd ic ates t hat waste
elec tric al and elec tron ic
produ c ts (WEEE)
shou ld be dispo sed of
separately f rom the
munic ipal waste stream.
2. Old elec tric al produc ts c an c on tain hazardous
substanc es so c orrec t dispo sal of your old app lianc e
will help prevent po tential negative c on sequenc es
f or the environ ment and human health. Your old
app lianc e may c on tain reusable parts that c ould be
used to repair other produc ts, and other valuable
materials that c an be rec yc led t o c on serve li mited
resourc es.
3. You c an take your applianc e either to the shop
where you purc hased the produc t, or c on tac t your
loc al government waste off ic e f or details of your
nearest authorized WEEE c ollec tion point.
For the most up t o date inf ormation f or your c oun try
please see www. lg . c om/ g loba l/ rec yc ling
Transporting and Storage
• Do no t loo se the band ing, when modu le is
transpo rtedby truc k, ship and etc.
In c ase of loo se band ing , modu le will be shaken,
which may c ause damage, like glass breaking.
• Do no t stack on more than on e pallet. Maximum
height is two pallets.
Severe stacking c an give stress to the modu le and
may c ause produ ct damage.

11
A
pp
e
ndi
x
.
M
ec
h
a
ni
ca
l
In
s
t
a
ll
a
t
io
n
:
60Ce
l
l M
od
e
l
Fig.1 Bolting
Type
Fig.2 Clamping
Type
①
②
①
②
②
①
②
①
A
B
A
B
① : 200mm
② : 300mm Front : 6000Pa
Rear : 5400Pa A : 200mm
B : 400mm Front : 6000Pa
Rear : 5400Pa
Fig.3 Clamping
Type
Fig.4 Clamping
Type
A
B
B
A
A
B
B
A
A : 200mm
B : 400mm
Front : 5400Pa
Rear : 5400Pa
A : 120mm Front : 1800Pa
Rear : 1800Pa
B : 200mm Front : 2400Pa
Rear : 2400Pa
Fig.5 Clamping
Type
Fig.6 Clamping
Type
C
A
B
B
A
C
①
A
①
B
②
②
①
①
* 4 point installation is allowed in the following
cases:
1. Slope roof: If module is installed parallel to the
rooftop.
2. Flat roof: If installed with an additional stand such as
wind
A : 200mm
B : 400mm
Front : 6000Pa
Rear : 5400Pa
A : 120mm
*4point(①)
Front : 1800Pa
Rear : 1800Pa
C : 120mm
Front : 3200Pa
Rear : 1800Pa
A
:
120mm
B :
843
±
100mm
6point(①+②)
Front : 6000Pa
Rear : 5400Pa
Note)
All
mechanical installation method (Fig.1
to
Fig.6)
in this
appendix were
not
tested
by VDE.
It is
evaluated
by LG
internal
test.

12
A
pp
e
ndi
x
.
M
ec
h
a
ni
ca
l
In
s
t
a
ll
a
t
io
n
:
72Ce
l
l M
od
e
l
Fig.1 Bolting
Type
Fig.2 Clamping
Type
①
①
①
①
A
B
A
B
① : 300mm Front : 5400Pa
Rear : 4300Pa A : 250mm
B : 400mm Front : 5400Pa
Rear : 4300Pa
Fig.3 Clamping
Type
Fig.4 Clamping
Type
A
B
B
A
A
B
B
A
A : 250mm
B : 400mm
Front : 4300Pa
Rear : 4300Pa
A : 120mm
Front : 1600Pa
Rear : 1600Pa
B : 250mm
Fig.5 Clamping
Type
Fig.6 Clamping
Type
C
A
B
B
A
C
①
A
①
B
②
②
①
①
* 4 point installation is allowed in the following
cases:
1. Slope roof: If module is installed parallel to the
rooftop.
2. Flat roof: If installed with an additional stand such as
wind
A : 250mm
B : 400mm
Front : 5400Pa
Rear : 4300Pa
A : 120mm
*4point(①)
Front : 1600Pa
Rear : 1600Pa
C : 120mm
Front : 3200Pa
Rear : 1600Pa
A
:
120mm
B
:
1012
±
100mm
6point(①+②)
Front : 5400Pa
Rear : 4300Pa
Note)
All
mechanical installation method (Fig.1
to
Fig.7)
and
bolting method
in this
appendix were
not
tested
by VDE.
It is
evaluated
by LG
internal
test.

13
A
pp
e
ndi
x
.
M
ec
h
a
ni
ca
l
In
s
t
a
ll
a
t
io
n
:
72Ce
l
l M
od
e
l
Fig7. Bolting T
ype
①
※ Only NEXTracker
① : 812mm Front : 2000Pa
Rear : 1750Pa
Note) When installed Fig.7, follow
the
NEXTracker’s recommended applied torque
and
materials
to
fasten
the modules.
Bolting
Method
Module
frame
Bolt
Flat
washer
Mounting
Rail
Flat
washer
Spring
washer
Nut
•
Four M8(5/16inch) stainless steel bolts,
four
nuts,
four
spring washers,
and
eight
flat
washers
are recommended
per
solar
module.
Clamp system
requirements
• The
clamp should
not be
touched
with the
module’s
glass.
• Use
corrosion resistant material clamps
and hardware.
→ If you use a
special clamp,
it
needs
to test for
compatibility
by LGE.
• Use
appropriate bolted connections
as per
clamp manufacturer’s
instructions.
•
Follow
the
clamp manufacturer’s recommended applied torque
to
fasten
the clamps.
Width
Height
Depth
Width
Depth
Height
<Middle
Clamp> <Edge Clamp>
Note)
All
mechanical installation method (Fig.1
to
Fig.7)
and
bolting method
in this
appendix were
not
tested
by VDE.
It is
evaluated
by LG
internal
test.

14
A
pp
e
ndi
x
.
E
x
p
ec
t
e
d
E
n
er
g
y
Y
i
e
l
d
b
y
in
s
t
a
l
l
c
ondi
t
io
n
※
Simulation Condition
※
1.
Module height
: 0.6 ~ 1.5m
2.
Albedo 0.15
~ 0.85
3. Tilt
angle
30º,
south face, latitude
36º
4.
Array distance
4.5m
Racking
Scene
2
lows landscape
installation
1 low
portrait
installation
H
H
* “H” is a minimum height from mounting ground to module.
** LGE recommended a minimum height of 1m.

LG Electronics Deutschland GmbH
Alfred-Herrhausen-Allee 3-5, D-65760 Eschborn, Germany
Contact: service-solar@lge.de
LG Electronics Inc. (Global HQ)
LG Twin Towers, 128, Yeoui-daero, Yeongdeungpo-gu,
Seoul 150-721, Korea
Contact: [email protected]
http://www.lg-solar.com
This document is subject to change without notice.
LG, LG logo and Life's Good are trademarks of LG Electronics, Inc. worldwide. Trademarks and
intellectual properties of LG Electronics, Inc. are protected by international copyright laws.
Document : II-A5(T)-IEC-V1-EN-201612
This manual suits for next models
23
Table of contents
Other LG Solar Panel manuals

LG
LG LG Q1K-V5 Series User manual

LG
LG LG N9C-G4 Series User manual

LG
LG LGxxxS1C(W User manual

LG
LG N1T-G4 Series User manual

LG
LG LG N1C-N5 Series User manual

LG
LG LG280N1CW-G4 User manual

LG
LG LG270N1C(W)-G3 User manual

LG
LG LGXXXN1CW-G4 Series User manual

LG
LG Neon 2 S1C L4 Series User manual

LG
LG LG240M1C User manual

LG
LG MonoX ACe User manual

LG
LG LG S1C-A3 Series User manual

LG
LG S2W-U5 Series User manual

LG
LG LGXXXQ1C-A6 User manual

LG
LG S1C-U6 Series User manual

LG
LG LG N2T-J5 Series User manual

LG
LG Q1C-A5 Series User manual

LG
LG LG240M1C User manual

LG
LG LGxxxN1CW-A3 Series User manual

LG
LG LG M1C Series User manual