Description
The ADC-AC-X1100-2PSE is a two door access control unit
featuring dual voltage power and includes one prewired
X1100. The 14”x 12”x 4.5” metal enclosure includes battery
space.
Equipment List
1. Pre installed AC power cord
2. Power Supply 24VDC / 3A (model: FPV4)
3. Secondary 12V supply (model: B100)
4. Pre-installed X1100 controller
Accessories included
• AC power cord
• Battery harness
QUICK GUIDE ADC-AC-X1100-2PSE
1/2 www.lifesafetypower.com
System Operation
The FPV4 power supply converts AC primary power to 24VDC for charging the battery set and powering the X1100 con-
troller, B100, locking device(s), and 24V auxiliary devices. The B100 is powered from the FPV4 Auxiliary terminals and
steps the 24V down to 12V to power any 12V auxiliary devices.
The battery set is charged by the red/black harness on the bottom edge of the FPV4. The battery set MUST be two 12V
batteries in series for a 24V battery set. Observe polarity or damage to the system will occur.
Positive lock power is prewired to the X1100 lock relay Common terminals. The lock positive should be wired to the NC
(Fail Safe) or NO (Fail Secure) terminal as appropriate. Each lock negative should be wired directly to the FPV (-) terminal
to minimize noise and surges in the system.
September 2020
Terminal Output Ratings
**Max currents listed are for individual terminals - total current at 12V and 24V not to exceed max rating of supply
Board Terminal Voltage Max Current** Notes
FPV4 DC OUT 24V 1.5A Output can be switched by FAI Input on FPV4
AUX OUT 24V 0.75A Max Current includes current drawn by B100
B100
DC OUT 12V 1.5A For additional 12V devices
J2 (DC OUT) 12V 1.5A For additional 12V devices
J5 (DC OUT) 12V 1.5A For additional 12V devices
J1 (DC IN) 24V 0.75A For additional 24V devices
J4 (DC IN) 24V 0.75A For additional 24V devices
X1100 OUT1 (NO or NC) 24V 1.5A Switched Lock Output - Ground at FPV4 (-) Terminal
OUT3 (NO or NC 24V 1.5A Switched Lock Output - Ground at FPV4 (-) Terminal
090920_rev1