Skyway SKS2GPK232 or 332
Page 2 of 2 2' x 4' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 or 3 Lamp T8
Ord ring Information
Explanation of Catalog Number. Example: SKS2GPK232UNVHI
Options/Acc ssori s
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X4.
El ctrical Wiring Options: Consult factory.
For motion or light s nsor: See Folio OA20-10 and OA20-30.
Sp cifications
P rformanc : In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80.
To reduce glare the average brightness at 65° shall not exceed 1511 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 67.1%.
Air Handling: (SKA only) side air passages for air supply or air return. Supply air is
discharged vertically. Optional side closure strips. Air return is also provided through the
lamp compartment through fixture body ends.
Mat rials:Chassis parts are die-formed code gauge cold rolled steel. Housing
has side rails
hemmed over and housing ends turned-in for safe handling.
Sp cifications (continun d)
Finish:Chassis xt rior–black baked polyester enamel. Cavity–white baked poly-
ester enamel minimum 86% reflectance. Rust preventative undercoating. R fl ctors-
95% reflective white powder coated.
L ns: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
El ctrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Lab ls: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix
to catalog no., ie: (A)
Skyway
Recessed
Fluorescent
Body Styl :
S= Static
A= Air
2
Fixtur
Width
C iling Typ :
G= Standard
Grid
T= Slot Grid
P
Sid L ns:
P= Frost White
Acrylic Lens
32
K
C nt r L ns:
K= Pattern 19
.156 Virgin
Acyrlic Lens
Lamp
Quantity
2=2 Lamp
3=3 Lamps
0.0 45.0 90.0 FLUX
0 1990 1990 1990
5 1972 1975 1978 188
15 1875 1891 1913 535
25 1702 1765 1831 815
35 1464 1589 1647 979
45 1156 114 1063 867
55 732 714 643 630
65 406 401 354 400
75 205 185 170 207
85 48 35 31 46
90 000
Mod l No. SKS2GPK232UNVC5
LER = FP - 69.3 IW - 51.9 BF - 0.77
Comparative yearly lighting energy cost per
1000 lumens = 3.46
Report Number: G2008169
Catalog Number: SKS2GPK232UNVC5
Lamps: (2) F32T8/ADV/841/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture
prismatic acrylic lens assembly.
Ballast: INC-2P32-LW-SC
Report is based on 3100 Lumens per lamp.
Efficiency: 75.3%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 45.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2572. 2478. 2365.
55 2008. 1958. 1764.
65 1511. 1493. 1318.
75 1246. 1124. 1033.
85 866. 632. 560.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 83 80 77 75 73 71 72 70 69
02 76 70 66 66 63 60 64 61 58
03 70 63 57 59 55 51 57 54 50
04 64 56 50 53 48 44 52 47 44
05 60 51 44 48 43 39 47 42 39
06 55 46 39 44 38 34 43 38 34
07 51 42 35 40 35 31 39 34 31
08 48 38 32 37 31 28 36 31 28
09 45 35 29 34 29 25 33 28 25
10 42 33 27 31 26 23 31 26 23
ZONE LUMENS % LAMP % FIXT
00-030 1537 24.8 32.9
00-040 2516 40.6 53.9
00-060 4013 64.7 86.0
00-090 4666 75.3 100.0
90-180 0000 0.0 000.0
00-180 4666 75.3 100.0
ZONAL LUMEN SUMMARY
Voltag :
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 3104 3104 3104
5 3082 3082 3092 293
15 2940 2945 2951 831
25 2672 2662 2625 1222
35 2284 2184 2158 1382
45 1710 1657 1665 1284
55 1052 1099 990 955
65 608 639 565 626
75 323 296 284 333
85 90 74 66 88
90 15 16 8
Mod l No. SKS2GPK332UNVH3
LER = FP - 70.9 IW - 87.0 BF - 0.88
Comparative yearly lighting energy cost per
1000 lumens = 3.38
Report Number: G2008332
Catalog Number: SKS2GPK332UNVH3
Lamps: (3) F32T8/ADV/841/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture
prismatic acrylic lens assembly.
Ballast: ICN-3P32-SC
Report is based on 3100 Lumens per lamp.
Efficiency: 75.4%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 45.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3804. 3686. 3704.
55 2885. 3014. 2715.
65 2263. 2379. 2103.
75 1963. 1895. 1726.
85 1624. 1336. 1191.
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE LUMENS % LAMP % FIXT
00-030 2346 25.2 33.5
00-040 3728 40.1 53.2
00-060 5967 64.2 85.1
00-090 7014 75.4 100.0
90-180 0000 0.0 000.0
00-180 7014 75.4 100.0
ZONAL LUMEN SUMMARY
SK Standard Skyway
SY For NYC Code – I.B.E.W. Manufactured
Lamp:
(By Others)
32=T8 32W
(Nominal 48")
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 83 80 77 75 73 71 72 70 68
02 76 70 66 66 63 60 64 61 58
03 70 63 57 59 55 51 57 53 50
04 64 56 50 53 48 44 51 47 44
05 60 50 44 48 43 39 47 42 38
06 55 46 39 44 38 34 42 38 34
07 51 42 35 40 35 31 39 34 30
08 48 38 32 37 31 28 36 31 28
09 45 35 29 34 29 25 33 28 25
10 42 33 27 31 26 23 31 26 23
Ballast Typ :
Ballast
<20THD <10THD Factor
1 or 2 Lamp Elec. T8 SO* HI* 0.88
1-3 Lamp Elec. T8 O3* H3* 0.88
Advance Optanium
1 or 2 Lamp Elec. T8 – C5* 0.77
1 - 3 Lamp Elec. T8 – C6* 0.77
LOL Dimming T8 PS*–
*Instant Start Standard
Ot er dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
I
OR H3 Ballast Code.
Job Information Type:
For Factory Tec nical Information: (978) 657-7600 • Fax (978) 658-0595 08/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve t e rig t to c ange details of design, materials and finis .
www.lig tolier.com © P ilips Group S ction 5/Folio MA12-18 R v. B