0.0 45.0 90.0 FLUX
0 1256 1256 1256
5 1228 1256 1275 120
15 1152 1262 1391 360
25 1040 1290 1445 582
35 896 1173 1177 689
45 727 884 1159 729
55 533 752 791 636
65 303 384 346 338
75 74 103 139 119
85 10 21 29 26
95 56 77 61 96
105 227 449 262 377
115 426 729 837 691
125 622 1041 1042 828
135 802 1144 1339 854
145 956 1177 1360 733
155 1076 1200 1305 553
165 1159 1215 1255 343
175 1202 1221 1227 116
0.0 45.0 90.0 FLUX
0 749 749 749
5 730 749 764 71
15 687 753 829 215
25 622 771 865 348
35 539 707 722 417
45 440 545 695 441
55 324 454 487 389
65 191 217 210 208
75 48 62 84 73
85 7 13 17 15
95 16 27 36 31
105 88 106 138 122
115 232 363 322 308
125 356 481 677 457
135 459 619 692 465
145 548 739 796 437
155 623 737 857 341
165 679 724 773 206
175 714 725 730 69
CANDELA DISTRIBUTION
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Roa , Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change etails of esign, materials an finish.
© 2007 a Genlyte company Section 5/Folio K37-14
Job Information Type:
Options/accessories
Single Cable an Canopy. Catalog Number: EC60.
Single Cable, Straight Cor an Canopy. Catalog Number: ECC60.
Electrical Wiring Options: Consult factory.
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Specifications
Performance: In an installation of 2 lamp 28W Iuminaires with a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall be not
less than .74. Can elas at 65° shall not excee 210 (10 cell). To control veiling
reflections, Iuminaire output in the 30°- 90° zone shall be not less than 35%.
Materials: Chassis parts are ie-forme 20 gauge col rolle steel, En caps
are 18 guage col rolle steel with a ribbe accent.
Louver: Pre-ano ize aluminum (Coilzak®or equal).
Finish: Louver–low iri escence semi-specular ano ize aluminum (stan ar ).
Specifications (continue )
Chassis: Flat white polyester pow er coat (stan ar ).
Rust preventive un ercoating.
Electrical: Thermally protecte class “P” ballast, non PCB. If K.O. is within 3"
of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL an ULc Liste .
EL
Fixture
Length:
4= Nominal 48"
8= Nominal 96"
10
Numbe
of Cells:
10 = 1 row of 10
(48” Length)
X2
Lamp
Quantity*
2
=
2 Lam
Lamp Type/
Fixtu e Length:
28
=
T5 28W
54=T5 54W2
(Nominal 48")
Options:
A appropriate
suffix to catalog
no, ie: (GLR)
Lytecel™
-EL EL4MF10LX228 or 254
Page 2 of 2 Uplight/Downlight, Pen ant, 3-9/16" Deep, 10-13/16" Wi e
48" or 96" Nominal Lengths, 2 Lamp T5
Mo el No. EL4MF10LX228UNVPG
LER = FP - 38.3 IW - 66 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $6.27
Or ering Information
Explanation of Catalog Number. Example: EL4MF10LX228UNVPG
Report Number: G2007025
Catalog Number: EL4F10F10LX228UNVPG
Lamp: (2) F28T5
Luminaire: Lytecel EL Downlight with Semi
Specular Louver
Ballast: Tria B228PUNV-C
Report is base on 2900 Lumens per lamp.
Efficiency: 79.5%
CIE Type-Direct-In irect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.5
Shiel ing Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.200 3.960
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 5270. 6528. 8324.
55 4784. 6704. 7191.
65 3828. 4349. 4208.
75 1571. 2029. 2749.
85 680. 1263. 1652.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 78 74 71 58 56 54 47 46 45
02 71 65 60 51 48 45 42 40 38
03 65 57 52 45 41 38 37 35 32
04 59 51 45 40 36 32 33 30 28
05 54 45 39 36 31 28 30 26 24
06 50 40 34 32 28 24 27 23 21
07 46 36 30 29 25 21 24 21 18
08 43 33 27 26 22 19 22 19 16
09 40 30 24 24 20 17 20 17 15
10 37 28 22 22 18 15 19 15 13
ZONE LUMENS % LAMP % FIXT
00-030 634 10.9 13.8
00-040 1051 18.1 22.8
00-060 1881 32.4 40.8
00-090 2178 37.5 47.2
90-180 2436 42.0 0052.8
00-180 4613 79.5 100.0
ZONAL LUMEN SUMMARY
Mo el No. EL4MF10LX254UNVPG
LER = FP - 68.5 IW - 119 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.50
Report Number: G2007011
Catalog Number: EL4MF10LX254UNVPG
Lamp: (2) F54T5
Luminaire: Lytecel EL Downlight with Semi
Specular Louver
Ballast: Tria B254P UNV-D
Report is base on 5000 Lumens per lamp.
Efficiency: 81.9%
CIE Type-Direct-In irect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shiel ing Angles: 90 90
Plane: 0-Deg 90-Deg
Lumen Length: 46.200 3.960
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 8707. 10588. 13881.
55 7870. 11104. 11679.
65 6072. 6974. 6934.
75 2421. 3370. 4548.
85 972. 2041. 2818.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 79 76 73 58 56 54 47 46 45
02 72 67 62 51 48 45 42 40 38
03 66 59 53 45 41 38 37 34 32
04 60 52 46 40 36 33 33 30 28
05 55 46 40 36 31 28 29 26 24
06 51 41 35 32 28 24 27 23 21
07 47 37 31 29 25 21 24 21 18
08 44 34 28 26 22 19 22 19 16
09 41 31 25 24 20 17 20 17 15
10 38 28 22 22 18 15 19 15 13
ZONE LUMENS % LAMP % FIXT
00-030 1062 10.6 13.0
00-040 1751 17.5 21.4
00-060 3116 31.2 38.0
00-090 3599 36.0 43.9
90-180 4592 45.9 56.1
00-180 8191 81.9 100.0
ZONAL LUMEN SUMMARY
F
Body
Finish:
F=White
Top
Reflector:
X=
None
Voltage:
120, 277 or
UNV
=
Universal
Voltage
120-277
Body Style:
M= Individual
Module
J= Joiner
Module
L
Louve Finish:
L= Low Iridescence
Semi-s ecular
(standard)
*For any a itional ballast or wiring combination consult factory.
8˙ Units have lamps in tan em
CANDELA DISTRIBUTION
Ballast Type:
<20THD <10THD
2 Lamp Elec. T5 – PI††
(28 Watt)
2 Lamp Elec. T5 – PG ††
(28 Watt)
2 Lamp Elec. T5 HO – PG ††
(54 Watt)
††Instant Start (120, 277 or UNV)
††Program Rapi Start (UNV only)
Lytecel EL:
Elli soidal sha e
endant with
arabolic louver