 Page 2 of 11 
RD122 RACK MOUNT DIMMER 
 Version 1.4 OWNER’S MANUAL 11/23/2021 
www.lightronics.com 
Lightronics Inc. 509 Central Drive, Virginia Beach, VA 23454 (757) 486-3588 
UNIT DESCRIPTION AND FUNCTIONS 
 
The RD122 is a 28,800 Watt, 12 channel, rack 
mountable dimmer. Each of the channels has a 
capacity of 2400 Watts. It is controlled via low 
voltage signals which may be LMX-128 (3 wire 
multiplex) or USITT DMX-512. The unit is fan 
cooled. Channels may be independently assigned 
from the unit. The unit is over temperature protected 
and has a magnetic circuit breaker for each channel. 
There are three options for channel output 
connection panels. Options include: Duplex outlet 
panel with 1 connection per channel, External 
terminal strip (includes knockout cover) and 
Socapex connector panel (wiring per customer 
selection). The RD122 has several stand alone 
functions which enable it to operate without a control 
console. These functions include a storable scene 
which may be activated by an external switch 
closure, a programmable chaser and 7 factory set 
chase patterns. 
 
POWER REQUIREMENTS 
 
Each RD122 requires both hots from a SINGLE 
PHASE 120/240 VOLT AC or TWO PHASES OF A 
THREE PHASE 120/208 VOLT AC service. The 
neutral conductor is shared by two hots so it is 
important the two hots used are of different phases. 
EACH PHASE must be capable of providing 120 
AMPS. Line frequency is typically 60HZ. A 50HZ 
model is available for export. Refer to the dimmer 
electrical rating markings to determine the operating 
frequency. One or more RD122 dimmers may be 
installed into a standard 19" equipment rack with 
provisions for connection to an appropriate electrical 
service in accordance with the National Electrical 
Code. 
 
INSTALLATION 
 
PLACEMENT 
 
The RD122 is designed to be mounted in a standard 
19" equipment rack using the four mounting holes in 
the face plate of the dimmer. If the dimming system 
will be used for touring shows, it is recommended 
you provide additional support for the rear of the 
unit. The dimmer is fan cooled and requires no 
space between units when multiple dimmers are 
used. Air enters the dimmer through slots on the 
side and exits through holes in the bottom of the 
face plate. Make certain these ventilation holes are 
not obstructed. Do not place the RD122 where it will 
be exposed to moisture or excessive heat. The 
RD122 is intended for INDOOR USE ONLY. 
POWER CONNECTIONS 
 
 
 
 
 
 
 
Consult your local electrical codes to determine the 
proper wire type and wiring methods for your 
installation. 
 
Power enters the RD122 through a knockout sized 
for 1” conduit at the rear of the unit. Remove the top 
cover and install an appropriate cable clamp in the 
knockout hole. Pass the power cables through the 
hole. Behind the hole is a terminal block with three 
lugs. The connections labeled "H1" and "H2" are the 
line connections or "hots". The center connection 
labeled "N" is the neutral. There is an additional lug 
labeled "G" to the right of the terminal block. This is 
for connecting the unit to earth ground. When 
connections are completed, reinstall the cover and 
tighten the cable clamp. 
 
OUTPUT CHANNEL CONNECTIONS 
 
The RD122 can be supplied with one of several rear 
panel output options. Channel output connections 
are according to the rear panel selected. Channel 
connections generally proceed from left to right (if 
you are facing the rear of the unit).  Channel “1” will 
be on the left end. On a unit supplied with edison 
plug outlets, channels 1 - 6 are on the top row (from 
left to right). Channels 7 - 12 are on the lower row 
(from left to right). Connections for load Neutrals are 
provided. There is also a ground lug terminal to be 
used for your load circuit grounds. 
 
CONTROL SIGNAL CONNECTIONS (Units with 
DB9 connectors) 
 
A control signal enters the RD122 through 
connectors on the rear of the unit. If you are using 
the 3 pin multiplex protocol ("LMX" or compatible), 
plug the control cable into the 3 pin "XLR" connector. 
If you are using the DMX-512 protocol, plug your 5 
pin DMX control cable into the 5 pin to 9 pin adapter 
supplied with the RD122 and plug the 9 pin 
connector into the upper 9 pin connector on the rear 
of the dimmer. In either case, the lower 9 pin 
connector and the ribbon cable jumper that is 
supplied can be used to connect from the lower 
connector of the first dimmer into the upper 
connector of the next dimmer and so on. See the 
WARNING 
MAKE CERTAIN POWER IS 
REMOVED FROM THE FEED 
CIRCUITS BEFORE YOU BEGIN 
INSTALLATION.