Lightronics Inc. 509 Central Drive, Virginia Beach, VA 23454 Tel: 757 486-3588
OWNERS MANUAL Page 2 of 2
AS - 40 DIMMER
 Revision 3.1 06/16/1997
23(5$7,21
The AS-40 is internally set to be compatible with most 3 pin multiplex protocols. Contact Lightronics if you need to
change this to run with older Lightronics consoles and/or dimmers.
A "DIP" switch block is located on one end of the dimmer near the AC power cord. It has 4 switches on it which are
used to select which control console channels the dimmer will respond to. Use the table which is printed on the AS-
40 cover to select the proper switch settings. A "1" in the table indicates a switch in the UP position.
The AS-40 may be switched into a “non-dim” or “relay” mode by a small slide switch located near the LED power
indicator. Moving this switch to the right activates the relay mode. In this mode - all channels act as switches and
turn on to full intensity when the associated control console channel is set above aprox. 50 percent.
No pre-heat controls or trimmer circuits are used since the AS-40 has auto-sync circuitry
If you have older Lightronics dimmers with a mode switch - Set those dimmers to The NSI/SUNN mode to maintain
compatibility.
0$,17(1$1&($1'5(3$,5
TROUBLESHOOTING
CONTROL CABLE WIRING
The XLR multiplex connector pins are wired as follows:
REPAIR
The only user servicable parts are externally accessable fuses. Replace ONLY with 5 Amp, fast acting, 250 volt
fuses. Internal service on the unit by other than Lightronics authorized agents will void the warranty.
If service is required, contact the dealer from whom you purchased the unit or contact the Lightronics Service Dept..
á
 Ensure that power is applied to the dimmer.
á
 Check that light fixtures are functional.
á
 Check the dimmer fuses.
á
 Verify settings of dimmer DIP switches
á
 Check the multiplex control cable (a very
common source of problems).
á
 Check control console settings and operation.
á
 Check the control console for correct patching.
PIN # FUNCTION
 1 Common or Signal ground.
 2 Low voltage power to provide power to portable consoles.
 3 The multiplex control signal.