manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lignomat
  6. •
  7. Measuring Instrument
  8. •
  9. Lignomat S-10 User manual

Lignomat S-10 User manual

Package S-10
Lignomat USA LTD, 14345 NE Morris Ct., Portland OR 97230,
503-257-8957, 800-227-2105, [email protected] www.lignomat.com Page 1/3
Detection is the first step in Prevention.
Cable/pin system allows checking for moisture
accumulations in closed-up, unreachable
areas.
Install cables and pins in moisture critical
areas.
Measure periodically to check, if moisture
problems are back.
Bright LED display for optimum visibility.
Display has a life-time warranty.
Quality, performance and price have made
mini-Lignos very popular.
Description
The S-10 package consists of the moisture meter mini-Ligno S/DC for measurements
anywhere, anytime and cables and screws for remote monitoring.
Applications
For instant measurements spot-by-spot with the pins at the mini-Ligno S/DC and moni-
toring of remote, hard to reach areas with extension cables. For all applications where
moisture is of concern in buildings. Works for short and long-term monitoring,
Too much moisture, undetected for a prolonged time can cause severe damage inside a
building. Detection is the first step in prevention.
Advantages
The mini-Ligno S/DC moisture meter has a wide moisture range and calibrations for
softwood, hardwood, panel products as well as drywall, wall boards and other building
materials.
Extension cables allow monitoring areas which could be otherwise hard to reach or
inaccessible. Once cables/pins are installed, measurement can be taken at any time
to check progress in drying after water damage or to check if a problem re-occurrs
later-on. Add EL pins to reach up to 7″deep.
The mini-Ligno S/DC is a right meter for the construction, restoration and building
maintenance professional. It comes with pins and a connection for external elec-
trodes and monitor cables. Features are the wide measuring range and corrections for
measuring softwood, hardwood and panel products, gypsum and different types of wall
boards and a reference scale for concrete and other building materials.
Easiest monitoring of moisture problem areas
Leaky roofs, wet crawl spaces, faulty installed windows, broken pipes, a cracked wa-
terline behind a refrigerator can be a cause for moisture problems that affect the entire
building. Unnoticed moisture infiltration can have severe consequences, floors are
ruined, dry rot develops and structural components disintegrate.
Monitoring: Using extension cables has the advantage, that areas can be monitored,
which are out of easy reach when a building is being dried out or totally inaccessible
after the walls are closed up. System works well for short and long-term monitoring in
buildings. Measurements taken from the same spot at the same depth at different times
will produce a series of truly comparable moisture percentages.
The values show, if drying is proceeded as expected or if a new problem is occurring.
Pins (screws) are installed in the trouble spot and connected to a LP-mini cable. When
using screws, the meter indicates the highest moisture value in the measured area
between the screws. That could be at the surface or at the depth the screws have
been set, because un-coated screws measure the wettest spot. Teflon-coated pins only
measure at the tip, They will indicate a dry inside even if the surface is wet. See pins
page 3.
Standard cable length is 3 ft, upon request we supply cables up to 50ft long. Cables
should be ordered long enough to keep the open cable-end in an easily accessible
area. Measurements are taken by plugging the open cable-end into the meter. If cables
are already installed to monitor the drying-out process, they could be left in place for
long-term monitoring.
For data logging moisture and humidity:
-- for moisture content and relative humidity MC Tracker BL2 data logger
-- wireless recording system
-- for relative humidity only BL2 data logger
The LP-mini cable has loops on one end for the pins and screws and 2mm plugs on the
other end to fit the mini-Ligno S/DC. The cables in the package have a standard length
of 3 ft. Longer cables are available upon request.
If you wanted to use the PK probes for wood, order the D-11 package.
Meter Specifications S/DC
Size: 5.5”L X 2.75”W X 1”H
Measuring Range:
- Wood: 6-45%
- Gypsum, Sheetrock, Wall Boards: 0-7.5%
- Reference Scale: 0-99
Display: Resolution: 0.1% below 10% and 1% steps above 10%, life-time warranty
Calibrated for a wood temp of 70˚F (20˚C).
A correction table for different wood temperatures is listed in the manual.
Species Corrections
- 2 settings for wood species corrections: hardwoods, softwoods and panel products
- 3 Settings for gypsum, drywall and wall boards (water resistant, exterior, interior)
- 1 reference scale 0-99 for non-wood building materials (concrete)
Package Includes
1 mini-Ligno S/DC meter with wrist strap in carrying pouch with belt loop, 1 9V battery
1 laminated wood group card and 1 instruction manual
2 pair pins: 1 pair of 3/16” and 1 pair of 7/16” measuring depth (5mm, 10mm)
Built in connector for an assortment of external electrodes and extension cables
1 pair stainless steel screws
1 LP-mini cable
1 case M
For data logging moisture and humidity measurements automatically. we offer the
-- MC Tracker BL2 data logger
-- Wireless recording system
-- BL2 data logger for relative humidity, temperature, dew point temperature,
Lignomat USA LTD, 14345 NE Morris Ct., Portland OR 97230,
503-257-8957, 800-227-2105, [email protected] www.lignomat.com Page 2/3
Mini-Ligno S/DC has a true percent scale
for drywall, range 0-7.5%. Also included is a
reference scale and a WME scale for drywall.
EL pins can be ordered for any legnth be-
tween 7” and 1/2”
PK probes, EL pins, EG pins and screws
to monitor moisture conditions with
moisture meters, data loggers and wireless transmitters.
To connect EL and EG pins and stainless steel screws:
LP-H cable with loops and 4mm plugs connects to Ligno-VersaTec and Lignometer K via Adapter H.
LP-Hf cable with loops and 4mm jacks connects to MC transmitter (transmitter wires have 4mm plugs).
LP-mini-cable with loops and 2mm plugs connects to mini-Ligno DX/C, S/DC, MD/C and MC Tracker.
Loop nuts need to be ordered separately for EG and EL pins.
EL pins can be shortened to any length between 7” and 1/2” long.
To connect PK probes:
PK-H cable with 4mm plugs on both ends connects to Ligno-VersaTec and Lignometer K via Adapter H
PK-mini cable with 4mm and 2mm plugs connects to mini-Ligno DX/C, S/DC, MD/C and MC Tracker.
Lignomat USA LTD, 14345 NE Morris Ct., Portland OR 97230,
503-257-8957, 800-227-2105, [email protected] www.lignomat.com Page 3/3

Other Lignomat Measuring Instrument manuals

Lignomat Ligno-Scanner SD User manual

Lignomat

Lignomat Ligno-Scanner SD User manual

Lignomat Lignometer K User manual

Lignomat

Lignomat Lignometer K User manual

Lignomat Ligno-VersaTec User manual

Lignomat

Lignomat Ligno-VersaTec User manual

Lignomat Ligno-DuoTec BW User manual

Lignomat

Lignomat Ligno-DuoTec BW User manual

Lignomat Ligno-VersaTec V-0 User manual

Lignomat

Lignomat Ligno-VersaTec V-0 User manual

Lignomat mini-Ligno DX/C User manual

Lignomat

Lignomat mini-Ligno DX/C User manual

Lignomat PK Setup guide

Lignomat

Lignomat PK Setup guide

Lignomat Ligno-Scanner S User manual

Lignomat

Lignomat Ligno-Scanner S User manual

Popular Measuring Instrument manuals by other brands

Draminski TwistGrain instruction manual

Draminski

Draminski TwistGrain instruction manual

Victron energy BMV-501 user manual

Victron energy

Victron energy BMV-501 user manual

BioTempak BTP 72 Real Time user manual

BioTempak

BioTempak BTP 72 Real Time user manual

Groz FM-20 instruction manual

Groz

Groz FM-20 instruction manual

Siemens Pointek CLS200 operating instructions

Siemens

Siemens Pointek CLS200 operating instructions

Agilent Technologies E5071C manual

Agilent Technologies

Agilent Technologies E5071C manual

CiDRA SONARtrac 20924 Rework Instructions

CiDRA

CiDRA SONARtrac 20924 Rework Instructions

PFlow Industries D116 instruction manual

PFlow Industries

PFlow Industries D116 instruction manual

Bticino F41TMAN user manual

Bticino

Bticino F41TMAN user manual

Hanna Instruments HI96000 Series quick start guide

Hanna Instruments

Hanna Instruments HI96000 Series quick start guide

MKS Ophir LaserStar quick reference

MKS

MKS Ophir LaserStar quick reference

LumaSense technologies Impac IS 50-LO/GL user manual

LumaSense technologies

LumaSense technologies Impac IS 50-LO/GL user manual

TechnipFMC Smith Meter C2 Service manual

TechnipFMC

TechnipFMC Smith Meter C2 Service manual

Taidacent VAC8010F manual

Taidacent

Taidacent VAC8010F manual

Binding Union FAST 3485 Technical manual

Binding Union

Binding Union FAST 3485 Technical manual

Elenco Electronics XK-700 instruction manual

Elenco Electronics

Elenco Electronics XK-700 instruction manual

Tektronix P7260 user manual

Tektronix

Tektronix P7260 user manual

EMKO RS Pro ESM- 00 Series manual

EMKO

EMKO RS Pro ESM- 00 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.