manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Linak
  6. •
  7. Handset
  8. •
  9. Linak HB40 Operational manual

Linak HB40 Operational manual

Other Linak Handset manuals

Linak CB14 Operational manual

Linak

Linak CB14 Operational manual

Linak HB70 Operational manual

Linak

Linak HB70 Operational manual

Linak Homeline HB10RF Operational manual

Linak

Linak Homeline HB10RF Operational manual

Linak HC20 PCBA Parts list manual

Linak

Linak HC20 PCBA Parts list manual

Popular Handset manuals by other brands

GE 28101EE1 Quick setup guide

GE

GE 28101EE1 Quick setup guide

Kyocera IRIDIUM KI-G100 user guide

Kyocera

Kyocera IRIDIUM KI-G100 user guide

SW Comms ShoreTel 212k quick guide

SW Comms

SW Comms ShoreTel 212k quick guide

iPECS LIP-9020 user guide

iPECS

iPECS LIP-9020 user guide

Polycom KIRK 5020 quick guide

Polycom

Polycom KIRK 5020 quick guide

ASCOM I62 - user manual

ASCOM

ASCOM I62 - user manual

Philips TD6736/BH051P user manual

Philips

Philips TD6736/BH051P user manual

LG-Ericsson LIP-9010 user guide

LG-Ericsson

LG-Ericsson LIP-9010 user guide

Mitel 112 manual

Mitel

Mitel 112 manual

SBC SBC-381H installation manual

SBC

SBC SBC-381H installation manual

Mitel 5602 user guide

Mitel

Mitel 5602 user guide

Swissvoice ePure HD manual

Swissvoice

Swissvoice ePure HD manual

ASCOM d81 Messenger Safety instructions

ASCOM

ASCOM d81 Messenger Safety instructions

SpectraLink 7522 quick start guide

SpectraLink

SpectraLink 7522 quick start guide

Avaya L100 Series Release notes

Avaya

Avaya L100 Series Release notes

GE 27950EE1 user guide

GE

GE 27950EE1 user guide

Mitel OpenPhone OpenPhone 27 user guide

Mitel

Mitel OpenPhone OpenPhone 27 user guide

GE 1583 user guide

GE

GE 1583 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PRODUCT DATA SHEET
HANDSET
HB40
Features:
• Handset for up to 4 actuators
• Only control current, max. 100 mA per channel
in the handset
• High-strength plastic housing
• Ergonomic design and easy-touch buttons
• Hook for easy placement
• 2.5 m straight cable
• Protection class: IP51. (HB44H for CARELINE IP54)
• Colour: black
Options:
• Protection class: IP65 or IP66 (Not HB40A)
• 0.5m/0.6m coiled cable or with extra long cable -
see ordering example
• Customised front cover
• Anti-slip rubber tip for placement on a flat surface
(special article)
• Colour: grey
Usage:
• Ambient temperature: +5º to +40° C
• HB40 is compatible with CB8-T, CB9..AX (not
CH.4), CB12 and CB18
• HB40A is compatible with CB8-A battery version.
Fitted with plug for battery charger CH08.
• HB40E is compatible with CB9Px (except CB9..
PM/PN) and CB14
• HB44H is only compatible with CB9..Ax (if CH.4)
4 channels
• HB40T is only compatible with CB7 (max. 2
channels)
The HB40 series handsets are designed for use
with LINAK®control boxes.
These sturdy compact units are ergonomically
designed and ideal for a vast range of applica-
tions from patient care beds and office furni-
ture to industrial and agricultural duties.
B4
4H for CARELINE IP54)
6
(
Not HB40A)
th
extra long cable -
nt
on a flat surface
C
AX
(not
ry
versi
on
o
.
H
08.
t
C
B9
* only for channels 1, 2 and 3
CB7 CB8 CB8A CB9..Ax CB9..Px
(not CB9..PM/PN
CB12 CB14 CB18
HB4xO x x* x x
HB4xA x
HB4xE x x
HB4xH x (4ch.)
HB4xT x
2 Up 2 Down
1 Up 1 Down
3 Up 3 Down
4 Up 4 Down
Dimensions:
Compatibility:
Channels as follows:
HB41000 - 000000
Cable: Black Grey
0015751 0015752
00914519 00914520
0015761 0015762
00914517 00914518
0015763 0015764
0015114
0015119 0015150
0015766 0015767
0015422
IP - rating: 0 = IP51
1 = IP65
2 = IP66-Washable
4 = IP54
Note: for HB4xA: IP 21
Colour: 0 = black
1 = grey
Front cover no: customer designed front cover
Special code: if not 00
Functionality: 0 = HB40-like
A = for use with CB8-A, (only HB41/42/43)
E = Matrix for use with CB14, CB9..Px (not CB9..PM/PN)
H = for use with CB9
T = for use with CB7 (only HB41/42)
No. of rows: 1 - 4
0 = 2500 mm, 9-Wire straight, 8 p. DIN plug
1 = 600 mm, 9-Wire coiled, 8-p. DIN plug
(HB43 and HB44)
2 = 500 mm , 6-Wire coiled, 8-p. DIN plug
(only HB41x, HB42x and HB43E)
3 = 500 mm , 6-Wire coiled, without plug
(only HB41 and HB42)
4 = 500 mm , 4-Wire coiled, 4p. Modular plug
(only HB41)
5 = 600 mm , 9-Wire coiled, 8p. DIN, extra long
straight end
9 = 600 mm , 5-Wire coiled, 8p. Modular plug.
(only CB7)
Choice of rubber tip to be specified separately (special article).
HB40
Ordering example:
Overview for HB4x functionality: 0, A, E, H, T.
HB41 0/A/E/H/T HB42 0/A/E/H/T HB43 0/A/E/H HB44 0/E/H
4U
3D
2U
4D
3U
2D
1U 1D
3U 3D
2D
1D
2U 2D
1U 1D1U 1D
2U
1U
Specifications subject to change without prior notice.
It is the responsibility of the product user to determine the suitability
of LINAK A/S products for a specific application. LINAK will at point of
delivery replace/repair defective products covered by the warranty
if promptly returned to the factory. No liability is assumed beyond
such replacement/repair.
Copyright ® LINAK 2007.09 . MA M9-02-100-L . Chapter 9.1
HB42-130 HB42-039 HB42-040 HB43-000 HB43-002HB42-999
HB42-001 HB42-004HB41-000 HB41-098 HB42-000HB41-999
HB40 Standard front covers:
When ordering check that the handset functionality corresponds to the symbols on the front cover.
The last 2 digits in the front cover code are to be used in the ordering example (xx).
HB43-032 HB44-056HB44-000 HB44-999HB43-999