CLEAR SHIELD HOOD PAPR UNIT
GENERAL CLEANING GUIDELINES
K48861, K48863
Maintenance and Storage
• Read and follow all steps set forth in the
Clear Shield Hood PAPR Unit Operator’s
Manual.
• Replace damaged or dirty air lters.
Filters cannot be washed or cleaned with
compressed air. Never reuse a dirty air lter.
• Never use solvents or abrasive cleaning
solutions to clean the respirator. Keep water
and other uids out of blower assembly.
• Maintain accurate records of lter
replacement and respirator maintenance.
• Cleaning is recommended after each use.
• After the whole set of the product is
completely dry, connect the hood with
the blower unit, install the new lters or
accessories, and store it in a disposable
medical plastic bag.
IMPORTANT NOTICE:
• Follow your facility’s protocols for proper
disposal of cleaning equipment and solutions.
Recommended Disinfection Method
Sodium hypochlorite disinfection method
(free chlorine concentration is 5000 ppm
(0.5%)). This concentration standard is
derived from the “Guidelines for Temporary
Infection Control for Nursing Suspected or
Diagnosed Filamentous Hemorrhagic Fever
in Medical Institutions” issued by the WHO
(World Health Organization) in August 2014.
http://www.who.int/csr/resources/who-ipc-
guidance-ebolanal-09082014.pdf?ua=1
Product Disinfection Handover
The Clear Shield Hood PAPR Hood can be
handed over using the following steps:
1. Prepare a graduated spray bottle (1.0- 1.5L
volume) with 1L clean water inside. Making
the disinfecting solution of 5000mg/L by
adding 10pcs of LIRCON eervescent tablets
with an eective chlorine content of 500mg/
tablet and mix thoroughly. (For reference
only, subject to actual conditions of each
hospital).
2. When medical workers wearing the Clear
Shield Hood PAPR leave isolation section,
please make sure the blower unit is always
working (DO NOT turn it o). Other medical
workers spray the whole hood PAPR system
(hood, hose, belt, and blower unit) with
chlorine-containing disinfectant.
3. After spraying disinfectant, turn o the
blower unit, take o the hood (from inside
out), blower unit, and hose and pack them
with the clean medical plastic bags. Put them
in the designated area of the buer zone,
and take them to the disinfection area by a
designated person for disinfection.
Disinfection Process in
Designated Area
Preparations:
1. Disinfectors must wear a full set of
protective equipment including protective
clothing, mask, and goggles.
2. Prepare two layers of nitrile gloves or vinyl
gloves before cleaning.
3. Prepare 5000mg/L chlorine-containing
disinfectant and medical gauze.
Initial Process:
1. Get the complete protective equipment out
from the disposable medical bag.
2. Separate each part (hood, hose, blower unit)
carefully.
Hood Disinfection:
The Clear Shield Hood PAPR Hood can be
cleaned following the steps below:
1. Remove the sweatband from the headband
inside the hood, put the sweatband into a
disposable medical plastic bag and discard.
2. Clean the hood inside and outside surface
three times by using the medical gauze
soaked with chlorine disinfectant (0.5%).
Dip the neutral (PH6-8) cleaner to wipe the
hood and use the clean water to wash o the
remaining liquid of the cleaner.
3. Put the disinfected hood into a disposable
medical plastic bag and dry them in a
pollution-free area. Please make sure to
assemble the new sweatband correctly
before next use.
IMPORTANT NOTICE:
• If there is sucient inventory for the hood,
one-time use is recommended.
• The cleaned Hood should be carefully
inspected per the Operator’s Manual.
• Store Helmet when not in use in accordance
with the Operator’s Manual.
Blower Unit Disinfection
The Clear Shield Hood PAPR Blower Unit can
be cleaned by following the steps below:
1. Clean the surface of the blower unit
(including the belt) and the hose connection
area three times by using the medical gauze
soaked with chlorine disinfectant (0.5%).
a. Note: When the complete hood PAPR
system is running, the air is always clean
after ltration, so only need to clean the
hose connection area which is exposed to
the air.
2. Please clean the white area inside the blower
unit carefully.
a. DO NOT wash it with liquid, the liquid may
penetrate into the equipment and cause
damage.
CONTINUED ON BACK >>>
CUSTOMER ASSISTANCE POLICY
The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet
the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of
our products. Our employees respond to inquiries to the best of their ability based on information provided to them by the customers and the knowledge
they may have concerning the application. Our employees, however, are not in a position to verify the information provided or to evaluate the engineering
requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume any liability with respect to such information
or advice. Moreover, the provision of such information or advice does not create, expand, or alter any warranty on our products. Any express or implied
warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty of tness for any customers’
particular purpose is specically disclaimed.
Lincoln Electric is a responsive manufacturer, but the selection and use of specic products sold by Lincoln Electric is solely within the control of, and remains
the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric aect the results obtained in applying these types of
fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any
updated information.
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Avenue • Cleveland, OH • 44117-1199 • U.S.A.
Phone: +1.216.481.8100 • www.lincolnelectric.com
MC20-126 Issue Date /
© Lincoln Global, Inc. All Rights Reserved.
All trademarks and registered trademarks are the property of their respective owners.
3. Set the blower unit vertically, and open the
lter cover. Remove the pre-lter and particle
lter in order and put them into medical
plastic bags and discard. After removing the
lters, install the blower cleaning covers over
the white area inside the blower and the hose
connection outlet.
4. Soak the lter cover in 1000mg/L chlorine
disinfectant for 30 minutes.
a. Note: Please follow the disinfection
instructions formulated by your
organization and/or local regulatory
authorities for the target microorganism or
corona virus.
5. Clean the surface of the blower unit and the
particle lter installation area three times by
using the medical gauze soaked with chlorine
disinfectant (0.5%).
6. Remove the battery, and clean the battery
(including the connection area between the
battery and the blower unit) three times by
using the medical gauze soaked with chlorine
disinfectant (0.5%).
a. Please clean the contacts on the bottom of
the battery carefully. Make sure the area is
completely dry before next use or storage.
7. Dip the neutral (PH6-8) cleaner to wipe all
parts repeatedly and evenly, and use the
clean water to wipe the remaining liquid of
the cleaner.
8.Put the disinfected blower unit and battery
into a disposable medical plastic bag, dry
them in a pollution-free area, and remove
both blower cleaning covers.
IMPORTANT NOTICE:
• Soaking any parts of the blower unit is
prohibited.
• Insure all components are dry prior to reuse
or storage.
• Reassemble unit as described in the product
Operator’s Manual.
• After cleaning, the PAPR Blower Unit and
headgear should be inspected following
the inspection procedures in the Operator’s
Manual for that item.
Air Hose Disinfection
The Clear Shield Hood PAPR Air Hose can be
cleaned by following the steps below:
1. Remove the air hose cover, and put it into
disposable medical plastic bag and discard.
2. Soak the air hose is 1000mg/L chlorine
disinfectant for 30 minutes.
a. Note: Please follow the disinfection
instructions formulated by your
organization and/or local regulatory
authorities for the target microorganism or
corona virus.
3. Dip the neutral (PH6-8) cleaner to wipe the
air hose and use clean water to wash o the
remaining liquid of the cleaner.
4. Put the disinfected air hose into a disposable
medical plastic bag and dry them in a
pollution-free area. Or, connect the air hose
with the blower unit, and turn on the blower
unit to dry the air hose.
IMPORTANT NOTICE:
• Inspection of blower assembly and breathing
tube after each use is good practice.
• Replace breathing tube if damaged or if inside
of tube is dirty.
• Replace damaged or dirty air lters.
Filters cannot be washed or cleaned with
compressed air. Never reuse a dirty air lter.
• DO NOT immerse the battery pack during
cleaning.
• Use caution when cleaning around the
battery pack connector pins on the bottom of
the motor/blower. It is critical not to bend or
break the pins.
• Ensure the battery pack and the connector
pins are thoroughly dry before next use or
storage. It is critical not to bend or break the
pins.
• Ensure all components are dry prior to reuse
or storage.
• Follow your facility’s protocols for proper
disposal of cleaning equipment and solutions.
• Read and follow all steps set forth in the Clear
Shield Hood PAPR Unit Operator’s Manual.
Lincoln’s Clear Shield PAPR system is approved by NIOSH for protection against particulates at a high eciency ltration level, and is currently authorized by an Emer-
gency Use Authorization (EUA) issued by the U.S. Food and Drug Administration (FDA) for use in healthcare settings by healthcare personnel when used in accordance
with Centers for Disease Control and Prevention (CDC) recommendations to prevent wearer exposure to pathogenic biological airborne particulates during respirator
shortages resulting from the COVID- outbreak. However, Clear Shield is not intended to be used as a medical device in healthcare surgical settings or in the presence
of a high intensity heat source or ammable gas, and has not been cleared by the FDA other than as stated in the EUA.

This manual suits for next models

1

Popular Safety Equipment manuals by other brands

Milwaukee BOLT User instructions

Milwaukee

Milwaukee BOLT User instructions

Petzl LYNX manual

Petzl

Petzl LYNX manual

MSA OptimAir Mask-Mounted PAPR User instructions

MSA

MSA OptimAir Mask-Mounted PAPR User instructions

Aqua Design ZOOM manual

Aqua Design

Aqua Design ZOOM manual

U-Line H-3441 quick start guide

U-Line

U-Line H-3441 quick start guide

SAR Hawk Sit Harness user guide

SAR

SAR Hawk Sit Harness user guide

CMC HELITACK AIRBAG quick start guide

CMC

CMC HELITACK AIRBAG quick start guide

Innotech UNI-EAP-01 manual

Innotech

Innotech UNI-EAP-01 manual

ABS Safety SG2-FL-ANSCHLUSS-K installation manual

ABS Safety

ABS Safety SG2-FL-ANSCHLUSS-K installation manual

Safety Solutions HUTCHENS DEVICE installation manual

Safety Solutions

Safety Solutions HUTCHENS DEVICE installation manual

A.HABERKORN KS 45 INSTRUCTIONS FOR USE AND TEST MANUAL

A.HABERKORN

A.HABERKORN KS 45 INSTRUCTIONS FOR USE AND TEST MANUAL

3M DBI SALA KM419 User instruction manual

3M

3M DBI SALA KM419 User instruction manual

Protekt SP101 instruction manual

Protekt

Protekt SP101 instruction manual

Helite Airbag OFF-ROAD user guide

Helite

Helite Airbag OFF-ROAD user guide

Daniamant Dan WL3-2 Installation and maintenance instructions

Daniamant

Daniamant Dan WL3-2 Installation and maintenance instructions

Klein Tools KONSTRUCT Series instructions

Klein Tools

Klein Tools KONSTRUCT Series instructions

Clarke SOG1 User instructions

Clarke

Clarke SOG1 User instructions

GemOne Sapphire V2 troubleshooting guide

GemOne

GemOne Sapphire V2 troubleshooting guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.