Contents of This Package:
• LBP-UPS-F Multifunctional UPS
Warning (Part No. 5-1666)
•Do not use this UPS with any power adaptor other than Lindsay Broadband Part No. 6506-056. •AC Power Adaptor
•A risk of explosion exists if the UPS battery is incorrectly connected or replaced by an incorrect type. (Part No. 6506-056)
A battery showing signs of swelling, cracking or leaking should be immediately replaced. •1m (3’) Coax Cable with F-Male Connectors
(Contact Lindsay Broadband if you need a replacement battery.) (Part No. 4008-160)
•CAUTION:Contains a Li-Ion Battery Pack. Follow all instructions to avoid risk of fire and burns. • User Manual (This document)
Do Not Open, Crush, Heat Above 50⁰C (122⁰F), or Incinerate.
Always recycle batteries in accordance with local regulations.
Options:
• 1m (3’) CPE Dual Power Cable – Part No. 4008-159 (F – Male to Dual 5.5 x 2.1mm & 5.5 x 2.5mm Barrel Connectors)
• 1m (3’) CPE Triple Power Cable – Part No. 4008-159-1 (F – Male to Triple 5.5 x 2.1mm, 5.5 x 2.5 Barrel Connectors, F – Male Connector)
• 4.6m (15’) CPE Power Cable – Part No. 4008-150-1 (F – Male to Stripped Pair of #16 AWG Wires [Red + Black])
• Replacement Li-Ion Battery Pack – Part No. 5-1666-RB
Product Overview: The LBP-UPS-F is an easy to install, Lithium-Ion technology based, standby UPS system. It is designed to continue to deliver regulated, low noise power to any
12–15 VDC powered CPE device (RFoG, RF amplifier, modem, router, wireless, CCTV etc.) during AC power failures.
Protection features include: battery charging and safety management, charge/discharge and over/under temperature monitoring, output overload and
short-circuit protection as well as input over-voltage, surge and reverse polarity protection. Other features include: microprocessor controlled operation,
manual ON/OFF control, and LEDs that provide status as well as visual fault indications. In the OFF condition, the UPS enters into an ultra-low power state to
save energy. The AC power adaptor and the LBP-UPS-F incorporate standard female F connectors for use with coax cables.
Operation: Under normal operation with AC power applied, the UPS delivers +15 VDC power to the CPE device from the AC power adaptor and at the same time
maintains optimal charge of the internal battery. The Power LED is illuminated BLUE to indicate normal AC powering.
When an AC power failure occurs, the UPS diverts +12 VDC battery power to the CPE device with zero transfer time. An AMBER LED is illuminated to indicate
backup mode powering. The CPE device will remain powered by the battery until the AC power is restored, at which time the UPS diverts AC converted
DC power back to the device with zero transfer time (the Power LED is again illuminated BLUE). The UPS has a typical 8-hour run time with a 400mA load. If
the battery voltage falls below its set minimum value, the UPS shuts down to prevent over-discharge of the battery. A fully discharged battery requires 2 – 3
days for full recharge.
To turn the UPS on, press and hold the ON/OFF pushbutton for more than 2 seconds. To turn the UPS off again, repeat the previous process.
Note: The LBP-UPS-F automatically turns power off to the CPE device when a fault is detected. Power will automatically be restored once the fault condition
is cleared.
Installation:
• Unpack and inspect the LBP-UPS-F for damage.
• Select a dry, well ventilated mounting location for the LBP-UPS-F.
Ensure that an AC power outlet is within a 1m distance.
• Using a quantity of 2 self-tapping screws (not supplied), mount the UPS using the mounting slots provided on the unit.
• Using the supplied coax cable, connect the AC power adaptor to the LBP-UPS-F IN port. Do not torque the connectors more than 35 in-lbs.
• Using an appropriate length of coax, connect the LBP-UPS-F OUT port to the power port of the CPE device (maximum load = 10W). Do not torque the
connectors more than 35 in-lbs.
• Always run cables such that they cannot be damaged by being walked on or by objects set on or against them.
• Plug the AC power adaptor into the power outlet. Press and hold the ON/OFF pushbutton for more than 2 seconds. Ensure that the UPS Power LED is
illuminated BLUE. The CPE device should now be powered on.
• Remove the AC power adaptor from the power outlet. The UPS Power LED should extinguish and the Battery Mode LED should illuminate AMBER. The
CPE device should remain powered.
• Plug the AC power adaptor into the power outlet and ensure that the UPS returns to normal operation.
LBP-UPS-F Multifunctional UPS for Customer Premise Equipment
User Manual
① ON/OFF Pushbutton
② Temperature Fault LED
③ Battery Mode LED
④ Power LED
⑤ Charge LED
⑥ Power Input F Connector
⑦ Power Output F Connector
⑧Battery Compartment Door
⑨ Mounting Slots
AC Power
Adaptor
To CPE
Device
This unit is designed for an indoor environment, protected from moisture. Its operating temperature range is 0⁰C (32⁰F) to 50⁰C (122⁰F).
ON/
OFF
Options:
Status LEDs:The LBP-UPS-F utilizes 4 LEDs that provide fast and easy indication of the status of the unit at any time. These LEDs also provide visual fault indications to
provide quick troubleshooting for the technician.
Battery Pack Replacement:
Specifications:
15V
DC
/ 1.5A
Standby Mode
V
IN
= V
OUT
Battery Mode
12V
DC
0.9A / 10W Max.
110%
0 mSec
Typical Run Time 200 / 400 / 800mA 16 / 8 / 4 Hours
Over / Under Temperature Monitor
Overcharge, Overdischarge
Output Short Overload
Input Over-Voltage
Input Reverse Polarity
6KV Input Surge
Battery Charging
0 - 45⁰C (32 - 113°F)
V
OUT
50⁰C (122°F) Max.
IN/OUT Connectors SCTE 02 F - Female
78 x 156 x 44 mm (3.1 x 6.1 x 1.7 Inches)
0.45 Kg (1.0 Lb)
UL2054, UN38.3 (Power Bank Safety)
UL60950-1 (Information Technology Equipment Safety)
IEEE 587 (C62-41-1991) Cat B3 6KV (Surge Withstand)
Complies With FCC 47 CFR Part 15, Class B (RF Emissions)
UPS Protection
Operating Temperature
Dimensions
Weight
Certifications/Approvals
* Note
1
Lindsay Part No. 6506-056 100-240V
RMS
AC To DC Switching Regulated Wall Adaptor
Input Power Source
1
Output Voltage
Output Current/Power
Overload Protection
Output Transfer Time
Li-Ion Protection
Lindsay Broadband Inc. | 2-2035 Fisher Drive, Peterborough, ON K9J 6X6 Canada | Tel: 1.705.742.1350
Information in this document is subject to change without notice.
Rev. 11/18 (LBB0100)
•Press and hold the ON/OFF pushbutton for more
than 2 seconds to turn the UPS off.
•Remove 2 screws from Battery Compartment Door.
•Slide Battery Compartment Door to the right and
remove.
•Unplug the Li-Ion battery pack and remove.
•Plug the replacement Li-Ion battery pack into the
UPS connector and place the pack into its
compartment.
•Replace the Battery Compartment Door and the 2
screws removed previously.
Always recycle batteries in accordance with local regulations.
Three optional CPE powering cables are available from Lindsay Broadband:
• 1m (3’) long Part No. 4008-159 allows easy connection from the LBP-UPS-F to CPE devices that accept either
5.5mm x 2.1mm or 5.5mm x 2.5mm barrel power connectors rather than an F connection
(modems, routers, wireless devices etc.). The cable has a male F connector at the UPS end and a
Y terminated in both 5.5mm x 2.1mm and 5.5mm x 2.5mm barrel power connectors at the CPE
end. Simply plug the appropriate connector into the CPE power port.
• 1m (3’) long Part No. 4008-159-1 is the same but also includes an F connection at the CPE end.
• 4.6m (15’) long Part No. 4008-150-1 has a male F connector at the UPS end and a stripped pair of #16 AWG
wires [Red + Black] at the CPE end.
Contact Lindsay Broadband for the optional CPE powering cables.
ON/
OFF
UPS Function
LED Color
LED Status
All LEDs
ON / OFF KEY Press > 2 sec to turn ON / OFF

Popular UPS manuals by other brands

Alpha Outback Energy Alpha FXM 650 user manual

Alpha Outback Energy

Alpha Outback Energy Alpha FXM 650 user manual

Manhattan 168212 Uuser manual

Manhattan

Manhattan 168212 Uuser manual

TSi Power UPS-550B operating instructions

TSi Power

TSi Power UPS-550B operating instructions

Atlantis Land OnePower A03-S801 user manual

Atlantis Land

Atlantis Land OnePower A03-S801 user manual

Tescom DS360H user manual

Tescom

Tescom DS360H user manual

Gtec LibraPro user manual

Gtec

Gtec LibraPro user manual

Staco Energy E2 user manual

Staco Energy

Staco Energy E2 user manual

Eaton 93E Installation and operation manual

Eaton

Eaton 93E Installation and operation manual

FSP Technology 10K user manual

FSP Technology

FSP Technology 10K user manual

Maruson SmartDual Series user manual

Maruson

Maruson SmartDual Series user manual

Riello Sentinel Dual SDH 2200 ER Brochure & specs

Riello

Riello Sentinel Dual SDH 2200 ER Brochure & specs

CyberPower Value1200ELCD user manual

CyberPower

CyberPower Value1200ELCD user manual

Manhattan 168229 Features & specifications

Manhattan

Manhattan 168229 Features & specifications

Belkin 600VA Quick install guide

Belkin

Belkin 600VA Quick install guide

Salicru SPS.400.TOP User's manual, installation and start-up

Salicru

Salicru SPS.400.TOP User's manual, installation and start-up

Borri B8031 operating manual

Borri

Borri B8031 operating manual

CyberPower BRG850AVRLCD user manual

CyberPower

CyberPower BRG850AVRLCD user manual

NXT Power NPTU250-GL-N user manual

NXT Power

NXT Power NPTU250-GL-N user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.