"RL"
LEFT OR RIGHT
HAND OPERATION
"PM"
SINGLE OR
DUAL GATE
"AC"
AUTO CLOSE
TIMER
"RP"
RUN ALARM
PRE-START ALARM
"OC"
MAXIMUM OPEN
CURRENT
"CC"
MAXIMUM CLOSE
CURRENT
"AD"
ADVANCED
PROGRAMMING
"BD"
BRAKE
DELAY TIME
"OR"
OPEN/RESET
INPUT
"TG"
ANTI
TAILGATE
"RT"
MAXIMUM
RUN TIMER
"SB"
SINGLE BUTTON
INPUT SETUP
"SM"
STAGGER
MODE
"ST"
STAGGER
TIME
"AR"
AUXILIARY
RELAY MODE
"RD"
REVERSE
DELAY TIME
"CP"
CONSTANT
PRESSURE MODE
"LP"
LOW POWER
MODE
POWER
FAILURE MODE
"FS"
"SP"
SHADOW LOOP
OPEN PREVENTION
"SS"
SOFT START/STOP
DURATION
"CT"
RESET CYCLE
COUNT
"MA"
MAINTENANCE ALERT
TRIGGER
"MT"
MID-TRAVEL
STOP POSITION
APEX FUNCTION
DISPLAY INDICATIONS
"RA"
RADIO
ENABLE
"TL"
LEARN
TRANSMITTERS
"TD"
DELETE
TRANSMITTERS
"ML"
LEARN MGT
TRANSMITTERS
"MD"
ERASE MGT
TRANSMITTERS
"CL"
RESET TO
FACTORY DEFAULTS
MOTOR TYPE
SELECTION
"MO"
ANTI-TAILGATE
ENABLE
"AT"
"OT"
OBSTRUCTION
DETECTION TYPE, b1, b2
"RC"
REMOTE CLOSE
OBSTRUCTION ACTIVE
"OO"
OPEN OBSTRUCTION
INPUT ACTIVE
"MM"
MGT MONITIRING
FUNCTION
"RO"
REMOTE OPEN
OBSTRUCTION ACTIVE
"CO"
CLOSE OBSTRUCTION
INPUT ACTIVE
FUNCTION
LEFT HAND
RIGHT HAND
"RL"
*** FOR LRA ARM INSTALLATIONS ONLY: ***
FOR LRA PULL-TO-OPEN INSTALLATIONS (GATE SWINGS IN TO
OPEN) LEAVE THE CONTROLLER SET FOR RIGHT HAND OPERATION
FOR LRA PUSH-TO-OPEN INSTALLATIONS (GATE SWINGS OUT TO
OPEN) SET THE CONTROLLER FOR LEFT HAND OPERATION
LEFT HAND INSTALLATION
(OPERATOR ON LEFT SIDE OF
GATE WHEN VIEWED FROM INSIDE)
RIGHT HAND INSTALLATION
(OPERATOR ON RIGHT OF GATE
WHEN VIEWED FROM INSIDE)
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
FUNCTION
DUAL GATE INSTALLATION
SINGLE GATE INSTALLATION
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SINGLE GATE
DUAL GATE
"PM"
PRESS UP OR DOWN
TO SCROLL DISPLAY
THROUGH FUNCTIONS
PRESS ENTER FOR
ONE SECOND TO
SELECT OPTION
(THE DISPLAY
WILL FLASH)
PRESS UP
OR DOWN
TO CHANGE
OPTION
ENTER
PROGRAMMING
KEYSTROKES
SELECT
FUNCTION
CURRENTLY
SET OPTION
OPTION READY
TO CHANGE
PRESS ENTER TO
DISPLAY CURRENTLY
SET OPTION
CHOOSE
OPTION
OR
UP
DOWN
OR
UP
DOWN
OPTION
STORED
PRESS ENTER
TO STORE
OPTION
SELECT
FUNCTION
ENTERENTERENTER
OR
UP
DOWN
OR
PRESS UP, DOWN
OR ENTER SELECT
NEXT FUNCTION
FUNCTION
SET TIMER VALUE
1 TO 59 SECONDS
AUTO CLOSE TIMER DISABLED
SET TIMER VALUE
1 TO 9 MINUTES
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AUTO CLOSE
TIMER
"AC"
FUNCTION
MAXIMUM LOAD RANGE NUMBER WILL BE
DISPLAYED. ADJUST TO THE PROPER VALUE
OPTIONS
PRESS AND HOLD THE ENTER BUTTON
ENTER
PRESS ENTER TO STORE THE VALUE
"CC"
MAX CLOSE
CURRENT
FUNCTION
MAXIMUM LOAD RANGE NUMBER WILL BE
DISPLAYED. ADJUST TO THE PROPER VALUE
OPTIONS
MAX OPEN
CURRENT
PRESS AND HOLD THE ENTER BUTTON
ENTER
PRESS ENTER TO STORE THE VALUE
"OC"
FUNCTION
RUN ALARM ON
PRE-START ALARM OFF
RUN ALARM ON
PRE-START ALARM ON FOR 1 - 9 SECONDS
OPTIONS
RUN ALARM
PRE-START ALARM
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
RUN ALARM OFF
PRE-START ALARM OFF
"RP"
Linear PRO Access APeX-II v2.1 Gate Controller Quick Programming Guide — Basic Programming —
PRESS UP & DOWN BUTTONS FOR 1-SECOND TO ENTER PROGRAMMING
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
FUNCTION OPTIONS
"RC"
REMOTE CLOSE
OBSTRUCTION ACTIVE
REMOTE CLOSE
OBSTRUCTION INACTIVE
REMOTE CLOSE
OBSTRUCTION ACTIVE
FUNCTION OPTIONS
"OO"
OPEN OBSTRUCTION
INPUT ACTIVE
OPEN OBSTRUCTION
INPUT INACTIVE
OPEN OBSTRUCTION
INPUT ACTIVE
MUST BE ON FOR
SLIDE GATES
FUNCTION OPTIONS
"CO"
CLOSE OBSTRUCTION
INPUT ACTIVE
CLOSE OBSTRUCTION
INPUT INACTIVE ONLY IF
SECOND GATE ACTIVE
CLOSE OBSTRUCTION
INPUT ACTIVE
MUST BE ON FOR
SINGLE GATES
FUNCTION
FOR NON-CONTACT SENSOR
FOR CONTACT SENSOR
OPTIONS
"OT"
OBSTRUCTION
DETECTION TYPE
FUNCTION OPTIONS
"RO"
REMOTE OPEN
OBSTRUCTION ACTIVE
REMOTE OPERATOR
OBSTRUCTION
INPUT INACTIVE
REMOTE OPERATOR
OBSTRUCTION
INPUT ACTIVE
MUST BE ON FOR
SLIDE GATES
Linear PRO Access APeX-II v2.1 Gate Controller Quick Programming Guide — Advanced Programming —
PRESS UP OR DOWN
TO SCROLL DISPLAY
THROUGH FUNCTIONS
PRESS ENTER FOR
ONE SECOND TO
SELECT OPTION
(THE DISPLAY
WILL FLASH)
PRESS UP
OR DOWN
TO CHANGE
OPTION
ENTER
PROGRAMMING
KEYSTROKES
SELECT
FUNCTION
CURRENTLY
SET OPTION
OPTION READY
TO CHANGE
PRESS ENTER TO
DISPLAY CURRENTLY
SET OPTION
CHOOSE
OPTION
OR
UP
DOWN
OR
UP
DOWN
OPTION
STORED
PRESS ENTER
TO STORE
OPTION
SELECT
FUNCTION
ENTERENTERENTER
OR
UP
DOWN
OR
PRESS UP, DOWN
OR ENTER SELECT
NEXT FUNCTION
PRESS UP & DOWN BUTTONS FOR 1-SECOND TO ENTER PROGRAMMING
"RL"
LEFT OR RIGHT
HAND OPERATION
"PM"
SINGLE OR
DUAL GATE
"AC"
AUTO CLOSE
TIMER
"RP"
RUN ALARM
PRE-START ALARM
"OC"
MAXIMUM OPEN
CURRENT
"CC"
MAXIMUM CLOSE
CURRENT
"AD"
ADVANCED
PROGRAMMING
"BD"
BRAKE
DELAY TIME
"OR"
OPEN/RESET
INPUT
"TG"
ANTI
TAILGATE
"RT"
MAXIMUM
RUN TIMER
"SB"
SINGLE BUTTON
INPUT SETUP
"SM"
STAGGER
MODE
"ST"
STAGGER
TIME
"AR"
AUXILIARY
RELAY MODE
"RD"
REVERSE
DELAY TIME
"CP"
CONSTANT
PRESSURE MODE
"LP"
LOW POWER
MODE
POWER
FAILURE MODE
"FS"
"SP"
SHADOW LOOP
OPEN PREVENTION
"SS"
SOFT START/STOP
DURATION
"CT"
RESET CYCLE
COUNT
"MA"
MAINTENANCE ALERT
TRIGGER
"MT"
MID-TRAVEL
STOP POSITION
APEX FUNCTION
DISPLAY INDICATIONS
"RA"
RADIO
ENABLE
"TL"
LEARN
TRANSMITTERS
"TD"
DELETE
TRANSMITTERS
"ML"
LEARN MGT
TRANSMITTERS
"MD"
ERASE MGT
TRANSMITTERS
"CL"
RESET TO
FACTORY DEFAULTS
MOTOR TYPE
SELECTION
"MO"
ANTI-TAILGATE
ENABLE
"AT"
"OT"
OBSTRUCTION
DETECTION TYPE, b1, b2
"RC"
REMOTE CLOSE
OBSTRUCTION ACTIVE
"OO"
OPEN OBSTRUCTION
INPUT ACTIVE
"MM"
MGT MONITIRING
FUNCTION
"RO"
REMOTE OPEN
OBSTRUCTION ACTIVE
"CO"
CLOSE OBSTRUCTION
INPUT ACTIVE
FUNCTION
ADVANCED PROGRAMMING FUNCTIONS
WILL NOT BE DISPLAYED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
ADVANCED
PROGRAMMING
"AD"
ADVANCED PROGRAMMING OPTIONS
WILL BE DISPLAYED
NOTE: ADVANCED PROGRAMMING
WILL STAY ENABLED AFTER
EXITING PROGRAMMING UNTIL
THE GATE CYCLES 50 TIMES
FUNCTION
SINGLE INPUT WILL OPEN OPERATOR,
IF OPERATOR IS ALREADY OPEN, SINGLE
INPUT WILL CLOSE OPERATOR
SINGLE INPUT WILL CYCLE OPERATOR
IN ORDER OF OPEN-STOP-CLOSE-STOP
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SINGLE BUTTON
INPUT SETUP
"SB"
FUNCTION
SETS THIS OPERATOR FOR
DELAYED OPEN
DISABLES STAGGER FUNCTION
SETS THIS OPERATOR FOR
DELAYED CLOSE
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
STAGGER
MODE
"SM"
NON-LRA DUAL
GATES ONLY
FUNCTION
SET STAGGER DELAY VALUE
1 TO 99 SECONDS
STAGGER TIMER DISABLED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
STAGGER
DELAY TIME
"ST"
NON-LRA DUAL
GATES ONLY
FUNCTION
PRESS ENTER FOR 1 SECOND
WHILE DISPLAY IS FLASHING, PRESS
UP OR DOWN TO CHANGE THE
MAXIMUM RUN TIME (10-99 SECONDS)
OPTIONS
MAXIMUM RUN
TIMER
DISPLAY SHOWS CURRENT
MAXIMUM RUN TIME SETTING
ENTER
ENTER
PRESS ENTER TO STORE THE VALUE
"RT"
FUNCTION
AUXILIARY RELAY USED FOR
MAGLOCK CONTROL
AUXILIARY RELAY DISABLED
AUXILIARY RELAY USED FOR
TICKET DISPENSER CONTROL
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AUXILIARY
RELAY MODE
"AR"
AUXILIARY RELAY USED FOR
WARNING STROBE LIGHT
AUXILIARY RELAY USED FOR
CONNECTION TO ALARM DEVICE
AUXILIARY RELAY USED FOR
MAGLOCK OR SOLENOID CONTROL
3 SECOND DELAY TO RE-ENERGIZE
FUNCTION
SET TIMER VALUE
1 TO 9 SECONDS
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
REVERSE
DELAY TIME
"RD"
FUNCTION
SET TIMER VALUE
0 TO 3 SECONDS
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
BRAKE
DELAY TIME
"BD"
FUNCTION
CONSTANT PRESSURE SET TO OFF
(MOMENTARY PRESSURE ON)
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
CONSTANT
PRESSURE MODE
"CP"
OPEN BUTTON SET FOR
CONSTANT PRESSURE
CLOSE BUTTON SET FOR
CONSTANT PRESSURE
OPEN AND CLOSE BUTTONS BOTH SET
FOR CONSTANT PRESSURE
NOT FOR
BARRIER GATES
FUNCTION
LOW POWER MODE DISABLED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
LOW POWER
MODE
"LP"
LOW POWER MODE #1
RADIO WILL WAKE AND ACTIVATE,
REVERSE LOOP WILL JUST WAKE
LOW POWER MODE #2 - RADIO OR
OPEN LOOP WILL WAKE AND ACTIVATE,
REVERSE LOOP WILL JUST WAKE
THE FIRE DEPARTMENT INPUT
WILL ALWAYS WAKE UP CONTROLLER
FUNCTION
STANDARD OPERATION
SHADOW LOOP INHIBITS CLOSING ONLY
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SHADOW LOOP
OPEN PREVENTION
"SP"
OPEN INHIBIT ON, SHADOW LOOP INHIBITS
OPENING AND CLOSING
FUNCTION
SET TO FAIL SAFE MODE
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
POWER
FAILURE MODE
"FS"
SET TO FAIL SECURE MODE
DC MODELS
ONLY
SET TO OPEN IMMEDIATE MODE
SET TO CLOSE
IMMEDIATE MODE
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
FUNCTION
SETS THIS MAINTENANCE ALERT TRIGGER
FOR 5, 10, 15, OR 25 THOUSAND CYCLES
DISABLES THE MAINTENANCE ALERT
FUNCTION
RESETS THE MAINTENANCE ALERT
INDICATOR AND SETS THE MAINTENANCE
ALERT COUNT TO ZERO
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
MAINTENANCE
ALERT TRIGGER
"MA"
FUNCTION
PRESS ENTER TO START THE CYCLE COUNT DISPLAY
1ST DISPLAY
NOTE: PRESS ENTER FOR 2 SECONDS
WHILE THE "CT" FUNCTION IS DISPLAYED
TO RESET THE CYCLE COUNT TO ZERO
RESET CYCLE
COUNT
"CT"
2ND DISPLAY3RD DISPLAY4TH DISPLAY
EXAMPLE ABOVE SHOWS 10,420 CYCLES
DECIMAL POINT LIT
ON 4TH DISPLAY
FUNCTION
SET SOFT START DURATION TIME
FROM 1 TO 10 SECONDS
SOFT START DISABLED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SOFT START/STOP
DURATION
"SS"
Copyright © 2019 Nortek Security & Control, LLC 231663 E
1-800-543-4283
linearproaccess.com
PRESS UP OR DOWN
TO SCROLL DISPLAY
THROUGH FUNCTIONS
PRESS ENTER FOR
ONE SECOND TO
SELECT OPTION
(THE DISPLAY
WILL FLASH)
PRESS UP
OR DOWN
TO CHANGE
OPTION
ENTER
PROGRAMMING
KEYSTROKES
SELECT
FUNCTION
CURRENTLY
SET OPTION
OPTION READY
TO CHANGE
PRESS ENTER TO
DISPLAY CURRENTLY
SET OPTION
CHOOSE
OPTION
OR
UP
DOWN
OR
UP
DOWN
OPTION
STORED
PRESS ENTER
TO STORE
OPTION
SELECT
FUNCTION
ENTERENTERENTER
OR
UP
DOWN
OR
PRESS UP, DOWN
OR ENTER SELECT
NEXT FUNCTION
PRESS UP & DOWN BUTTONS FOR 1-SECOND TO ENTER PROGRAMMING
"RL"
LEFT OR RIGHT
HAND OPERATION
"PM"
SINGLE OR
DUAL GATE
"AC"
AUTO CLOSE
TIMER
"RP"
RUN ALARM
PRE-START ALARM
"OC"
MAXIMUM OPEN
CURRENT
"CC"
MAXIMUM CLOSE
CURRENT
"AD"
ADVANCED
PROGRAMMING
"BD"
BRAKE
DELAY TIME
"OR"
OPEN/RESET
INPUT
"TG"
ANTI
TAILGATE
"RT"
MAXIMUM
RUN TIMER
"SB"
SINGLE BUTTON
INPUT SETUP
"SM"
STAGGER
MODE
"ST"
STAGGER
TIME
"AR"
AUXILIARY
RELAY MODE
"RD"
REVERSE
DELAY TIME
"CP"
CONSTANT
PRESSURE MODE
"LP"
LOW POWER
MODE
POWER
FAILURE MODE
"FS"
"SP"
SHADOW LOOP
OPEN PREVENTION
"SS"
SOFT START/STOP
DURATION
"CT"
RESET CYCLE
COUNT
"MA"
MAINTENANCE ALERT
TRIGGER
"MT"
MID-TRAVEL
STOP POSITION
APEX FUNCTION
DISPLAY INDICATIONS
"RA"
RADIO
ENABLE
"TL"
LEARN
TRANSMITTERS
"TD"
DELETE
TRANSMITTERS
"ML"
LEARN MGT
TRANSMITTERS
"MD"
ERASE MGT
TRANSMITTERS
"CL"
RESET TO
FACTORY DEFAULTS
MOTOR TYPE
SELECTION
"MO"
ANTI-TAILGATE
ENABLE
"AT"
"OT"
OBSTRUCTION
DETECTION TYPE, b1, b2
"RC"
REMOTE CLOSE
OBSTRUCTION ACTIVE
"OO"
OPEN OBSTRUCTION
INPUT ACTIVE
"MM"
MGT MONITIRING
FUNCTION
"RO"
REMOTE OPEN
OBSTRUCTION ACTIVE
"CO"
CLOSE OBSTRUCTION
INPUT ACTIVE
Linear PRO Access APeX-II v2.1 Gate Controller Quick Programming Guide — Advanced Programming —
FUNCTION OPTIONS
"MM"
MGT MONITORING
FUNCTION
UL 325 6TH EDITION
MONITORS BATTERY AND
CONNECTION OF MGT
TRANSMITTER
2 MISSED SIGNALS
RESULT IN ALARM
BEEPING
FUNCTION
SET LENGTH OF OPENING TIME
FROM 1 TO 99 SECONDS
MID-TRAVEL STOP DISABLED
(GATE RUNS FULL TRAVEL)
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
MID-TRAVEL
STOP POSITION
"MT"
FUNCTION OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
OPEN/RESET
INPUT
"OR"
OPEN COUNTER MODE
OPEN MODE OFF
OPEN SUPERVISED MODE
FUNCTION
ANTI-TAILGATE FUNCTION DISABLED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
ANTI-
TAILGATE
"TG"
ANTI-TAILGATE FUNCTION ENABLED
FUNCTION
TO DELETE ALL MGT TRANSMITTERS, PRESS ENTER FOR
2 SECONDS, (TO EXIT WITHOUT DELETING ANY, QUICKLY
PRESS ENTER)
ERASE MGT
TRANSMITTERS
"MD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER
IS READY TO DELETE ALL MGT TRANSMITTERS
"MD"
ENTER
PRESS ENTER
ENTER
THE DISPLAY WILL SHOW "DELETE ALL" AND THE
CONTROLLER RETURNS TO PROGRAMMING MODE
FUNCTION
INTERNAL RADIO RECEIVER DISABLED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
RADIO
ENABLE
"RA"
INTERNAL RADIO RECEIVER ENABLED
FUNCTION
TO DELETE ALL TRANSMITTERS, PRESS ENTER FOR
2 SECONDS, OR TO PICK TRANSMITTERS GO TO NEXT STEP
DELETE
TRANSMITTERS
"TD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER
IS READY TO DELETE ONE OR MORE TRANSMITTERS,
(TO EXIT WITHOUT DELETING ANY, PRESS ENTER)
"TD"
ENTER
PRESS ENTER
ENTER
OR
UP DOWN
ENTER
PRESS UP OR DOWN TO SCROLL THROUGH THE LIST
OF TRANSMITTER ID NUMBERS
THE TRANSMITTER ID NUMBER IS DISPLAYED
(TO EXIT WITHOUT DELETING, PRESS ENTER)
(TO PICK A DIFFERENT TRANSMITTER ID, PRESS UP OR DOWN)
PRESS ENTER FOR 2 SECONDS TO DELETE THE
TRANSMITTER DISPLAYED
FUNCTION
ACTIVATE THE MGT TRANSMITTER, THE DISPLAY WILL
FLASH "rE" - IF THE TRANSMITTER IS ALREADY ENTERED,
"DU" WILL BE DISPLAYED, IF DECODE IS BAD "ERROR" WILL
BE DISPLAYED
LEARN MGT
TRANSMITTERS
PRESS ENTER, "ML" WILL BLINK FOR 30 SECONDS WHILE
THE CONTROLLER IS READY TO LEARN AN MGT
TRANSMITTER
"ML"
ENTER
OR
UP DOWN
ENTER
DISPLAY WILL SHOW "--" FOR 5 SECONDS, THEN SHOW THE
TRANSMITTER'S ID NUMBER - REPEAT STEPS FOR
SECOND MGT TRANSMITTER IF USED
PRESS ENTER TO ACCEPT THE SELECTION
PRESS UP OR DOWN TO SELECT THE MGT FUNCTION:
"rE" = REVERSE "St" = STOP
"OP" = OPEN OBSTRUCTION "CL" = CLOSE OBSTRUCTION
FUNCTION
ACTIVATE THE TRANSMITTER
DISPLAY WILL SHOW "- -" THEN THE
TRANSMITTER ID NUMBER - IF TRANSMITTER
IS ALREADY ENTERED, "dU" WILL BE DISPLAYED,
IF DECODE IS BAD "ERROR" WILL BE DISPLAYED
LEARN
TRANSMITTERS
"TL" WILL BLINK FOR 30 SECONDS WHILE
THE CONTROLLER IS READY TO
LEARN A TRANSMITTER
"TL"
ENTER
PRESS ENTER (ONCE FOR EACH TRANSMITTER,
UP TO 40 TRANSMITTERS TOTAL)
FUNCTION
ANTI-TAILGATE ENABLE OFF
GATE REQUIRES AUTO OR MANUAL CLOSE
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
ANTI-TAILGATE
ENABLE
"AT"
ANTI-TAILGATE ENABLE ON
GATE CLOSES WHEN SHADOW LOOP CLEARS
FUNCTION
DC MOTOR ONLY WITH BRAKING
AC MOTOR ONLY
DC MOTOR WITH SOFT START/STOP
ALL LRA INSTALLATIONS USE D2
AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH BRAKING
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
MOTOR TYPE
SELECTION
NOTE: SELECTION
MUST MATCH
MOTOR BOARD!
"MO"
3 PHASE AC MOTOR
AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH SOFT START/STOP
FUNCTION
RESET TO
FACTORY DEFAULTS
"CL"
ENTER
WHILE "CL" IS DISPLAYED, PRESS ENTER
ALL PROGRAMMED DATA WILL BE CLEARED
AND THE FACTORY DEFAULTS WILL BE
STORED IN MEMORY.
NOTE: THIS FUNCTION WILL NOT ERASE
TRANSMITTERS, CURRENT SENSE VALUES,
OR MOTOR TYPE.
BARRIER GATES
ONLY
BARRIER GATES
ONLY
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES

Other Linear Controllers manuals

Linear LTM4650 Quick setup guide

Linear

Linear LTM4650 Quick setup guide

Linear ANALOG DEVICES DC2155A-A User manual

Linear

Linear ANALOG DEVICES DC2155A-A User manual

Linear LTC3828EUH User manual

Linear

Linear LTC3828EUH User manual

Linear ANALOG DEVICES DC2448A-C Quick setup guide

Linear

Linear ANALOG DEVICES DC2448A-C Quick setup guide

Linear ANALOG DEVICES DC2448A-B Quick setup guide

Linear

Linear ANALOG DEVICES DC2448A-B Quick setup guide

Linear DC2053A Quick setup guide

Linear

Linear DC2053A Quick setup guide

Linear LTC3875 User manual

Linear

Linear LTC3875 User manual

Linear ANALOG DEVICES DC1590B Quick setup guide

Linear

Linear ANALOG DEVICES DC1590B Quick setup guide

Linear DC1772A Quick setup guide

Linear

Linear DC1772A Quick setup guide

Linear ANALOG DEVICES EZ-PD CCG3 Quick setup guide

Linear

Linear ANALOG DEVICES EZ-PD CCG3 Quick setup guide

Linear LRA User manual

Linear

Linear LRA User manual

Linear LT1943 User manual

Linear

Linear LT1943 User manual

Linear LTM4636 User manual

Linear

Linear LTM4636 User manual

Linear ADI Power DC2654A User manual

Linear

Linear ADI Power DC2654A User manual

Linear ANALOG DEVICES LTC7106 Quick setup guide

Linear

Linear ANALOG DEVICES LTC7106 Quick setup guide

Linear Z-Wave Series User manual

Linear

Linear Z-Wave Series User manual

Linear DC1104A User manual

Linear

Linear DC1104A User manual

Linear LTC3300-1 User manual

Linear

Linear LTC3300-1 User manual

Linear ANALOG DEVICES DC2448A-A Quick setup guide

Linear

Linear ANALOG DEVICES DC2448A-A Quick setup guide

Linear LTM8003 Quick setup guide

Linear

Linear LTM8003 Quick setup guide

Linear ANALOG DEVICES DC2448A-D Quick setup guide

Linear

Linear ANALOG DEVICES DC2448A-D Quick setup guide

Popular Controllers manuals by other brands

Danfoss ECL Comfort 310 operating guide

Danfoss

Danfoss ECL Comfort 310 operating guide

FATEK M Series user manual

FATEK

FATEK M Series user manual

Cielo Breez Eco user manual

Cielo

Cielo Breez Eco user manual

Moen ARC-4200 installation guide

Moen

Moen ARC-4200 installation guide

Panasonic FP3 Technical manual

Panasonic

Panasonic FP3 Technical manual

BATSI MIE210MLP user manual

BATSI

BATSI MIE210MLP user manual

ESD electronic CAN-CBX-CPU5202 Hardware manual

ESD electronic

ESD electronic CAN-CBX-CPU5202 Hardware manual

Rain Bird ESP-LXME Quick reference guide

Rain Bird

Rain Bird ESP-LXME Quick reference guide

Haier YCZ-A001 Installation and operating instruction

Haier

Haier YCZ-A001 Installation and operating instruction

Kaysun KID-05.4 S user manual

Kaysun

Kaysun KID-05.4 S user manual

Casiiot SKU-SLCONT-24IR user manual

Casiiot

Casiiot SKU-SLCONT-24IR user manual

Danfoss AK-PC 781A user guide

Danfoss

Danfoss AK-PC 781A user guide

Lenovo ServeRAID M5225-2GB Quick installation guide

Lenovo

Lenovo ServeRAID M5225-2GB Quick installation guide

Siemens SIMATIC S7 System manual

Siemens

Siemens SIMATIC S7 System manual

Remote Control Systems ALPHA-3-LO instructions

Remote Control Systems

Remote Control Systems ALPHA-3-LO instructions

Chargery BMS16T Series owner's manual

Chargery

Chargery BMS16T Series owner's manual

DriSteem VAPOR-LOGIC 3 Conversion instructions

DriSteem

DriSteem VAPOR-LOGIC 3 Conversion instructions

DMX4ALL DMX-LED-Dimmer CC1 user manual

DMX4ALL

DMX4ALL DMX-LED-Dimmer CC1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.