Lite-Puter DX-610 User manual

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-I]
1
DX-610/DX-626
6CH.DMX DIMMER PACK
User Manual
Lite
Puter Enterprise Co., Ltd.

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-I]
1
INDEX
SAFETY INTRODUCTION .........................................................................................2
The Load Power ..................................................................................................2
Working Environment ..........................................................................................2
Suggested Dimming Lights..................................................................................2
Chapter 1. Introduction ............................................................................................3
1-1 Feature .......................................................................................................3
1-2 Brief device introduction .............................................................................3
1-3 Specification ...............................................................................................3
1-4 Front panel .................................................................................................4
1-5 Output terminal board / Sockets panel........................................................4
1-6 Wiring diagram ...........................................................................................5
Chapter 2. Operation ...............................................................................................6
2 - 1 Standard DMX512 Signal .....................................................................6
2 - 2 DMX start address setting ...................................................................6
2 - 3 Dimming/Switching setting ..................................................................6
2 - 4 Warm up setting (0…6%) .....................................................................7
2 - 5 Channel output status preview ...........................................................7
2 - 6 Manual dimming .....................................................................................7
2 - 7 Display the dimming value of DMX channel, internal temperature.
............................................................................................................................7
2 - 8 DMX status & DMX address ................................................................8
2 - 9 Protocol control ......................................................................................8
Guarantee ...........................................................................................................……9

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
2
SAFETY INTRODUCTION
The Load Power
Please refer to the data we suggested to ensure the normal total working hours
of DX-610/DX-626
1. If DX-610/DX-626 is installed in a rack, please make sure the rack is airy.
Otherwise the machine will become over-heat and result in the
mis-function.
2. DX-610: the max. output of each channel is10A: For testing (DO Not over 30
minutes)
DX-626: the max. output of each channel is 20A: For testing (DO Not over
30 minutes)
3. DX-610: the output of each channel isŊ8A: For several hours use (Theaters,
Stages)
DX-626: the output of each channel is16A: For several hours use
(Theaters, Stages)
4. DX-610: the output of each channel is 8A: Can work for the whole year
without switching off (Hotels, Restaurants, Buildings)
DX-626: the output of each channel is 12A: Can work for the whole year
without switching off (Hotels, Restaurants, Buildings)
Working Environment
1. TemperatureUnder 35°C
2. If the machine is installed in a rack, then the temperature inside the rack
must be under 45°C
3. Humidity40% --- 80%
Suggested Dimming Lights
Incandescent lamps, halogen lamps, low volt halogen lamps with ballast.

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
3
Chapter 1. Introduction
1-1 Feature
6 dimming channels.
Auto tracking of frequency and phase.
Temperature control device: When the temperature is over 45āthe fan will
start automatically.
Auto tracking of frequency: Enables stable dimming output in different
frequencies.
Testing function: Can do test without connecting a console.
Warm-up function to protect the loads. (Warm-up setting 0---6.0%)
1-2 Brief Device Introductions
DX-610: 10A no fuse breaker.
DX-626: 25A no fuse breaker.
Fan for temperature controlling to sink heat and
clean the dust inside. (37CFM X 1)
The front panel can be dismantled easily for
quick repair.
1-3 Specification
Power AC 90-240V, 45-63Hz, 3Ø4W, 1Ø2W
Output DX-610: Maximal output is 10A each channel
DX-626: Maximal output is 20A each channel
(Please refer to the user manual)
DMX signal output/ input DMX512/ 1990
DMX signal connector XLR 5Pin, RJ11-6p4c phone jack
Analog signal power input DC 0-10V
Analog input channel 6 channels
PIN 1~6CH1~6, PIN 7NC
PIN 8V+12V OUT, PIN 9GND
Analog signal connector D-Type Plug 9 Pin(F)
Dimension 482(W) x 88(H) x 300(D)mm
Location 19" 2U standard rack
Weight 8Kg

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
4
1-4 Front Panel
7 8 6 5 4 3 2 1
(1) Power on/ off switch (5) Function Key
(2) DMX OUT/ IN (5 pin) (6) Dimming VR of Channel 1- 6
(3) DMX IN (RJ11, phone jack) (7) No fuse breaker (Channel 1-3)
(4) LED display/ function keys (8) No fuse breaker (Channel 4-6)
1-5 Output Terminal Board / Sockets Panel
TERMINALTYPE
910
11 12 13
(9) DMX connector (RJ11, phone jack)
(12) Output terminal board (External
power no fuse breaker is necessary when
mounting.)
(10) DMX IN (XLR-3 pin) (13) Power input terminal board.
(DX-610: 20A Single phase;
DX-626: 40A Single phase)
(11) DMX OUT (XLR-3 pin)

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
5
AMERICAN TYPE
Output sockets (DX-610: 10A each channel; DX-626: 15A each channel, e
xternal
power no fuse breaker is necessary when mounting.)
SCHUKO TYPE
Output sockets (DX-610: 10A each channel; DX-626: 16A each channel, e
xternal
power no fuse breaker is necessary when mounting.)
1-6 Wiring Diagram
PS.: There are ‘3 PHASES 3 WIRES’ and ‘SINGEL PHASE 3 WIRES’ as option.

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
6
Chapter 2. Operation
2 - 1 Standard DMX512 Signal
2-2 DMX Start Address Setting
STEP-1 holdingDMX, press▲or▼to find the start address.
▲: move 1 number forward : up to Channel 512.
▼:move 1 number backward :down to Channel 1.
2-3 Dimming/Switching Setting
STEP-1 pressDMXkey into DMX status.
STEP-2 press and hold theFNCkey for 3 sec.
STEP-3 pressFNCkey to select channel.
STEP-4 press▲or▼to select dimming mode or switching mode.
DX-626 is a 6 channel dimmer pack so when setting this unit:
1 as d.001, the output is from Channel 1Channel 6.
2 as d.007, the output is from Channel 7Channel 12.
3 It is allowed for setting more than 1 piece of DX-626 at the same start
address.
Default settingAll channel are
dimming mode
This point is flashing when
receiving DMX signal.

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
7
(Dimming) (Switching)
2 - 4 Warm Up Setting (0…6%)
STEP-1 pressFNCkey .
STEP-2 pressFNCkey to select the setting channel, EX :select channel 1
STEP-3 press▲,▼key to adjust.
2 - 5 Channel Output Status Preview
STEP-1 Enter to DMX status and pressDMXkey.
STEP-2 press▲or▼to preview.
2-6 Manual Dimming
STEP-1 PushVR1-VR6to do the prompt dimming output of individual channel.
When there is another signal inputting from a console, it will take the higher value as
the output.
2 - 7 Display The Dimming Value of DMX Channel,Internal Temperature.
PressLto display the dimming value of DMX channel.
PressTto display the internal temperature.
Channel 1 set on 6% for warm up.

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
8
2-8 DMX Status & DMX Address
a.pressDMXto DMX status.
b.10 minutes unused of unit, the DMX will activate to DMX status.
2-9 Protocol Control
When the protocol control turn on, it only receive the DMX signal whose break width
range from 88us to 230us.
STEP-1 PressFNCand LED displays as below.
or
STEP-2 Pressand LED displays as below,
Protocol control is ON.
STEP-3 Pressand LED displays as below,
Protocol control is OFF.

ISO9001CERTIFIED
Lite-Puter
DX-610/626 [EUM-
]
9
Guarantee
1. Lite-Puter is only responsible for DX-610/DX-626 itself.
2. Lite-Puter guarantees to keep Lite-Puter’s fault products caused by
techniques, materials and any other logical reasons in good repair for free
within a year since the distributing date.
3. We do not offer door-visiting service. If the trouble appears in
Lite-Puter’s products, please deliver the equipment to local distributors or
Taipei headquarter.
*** Special Statement***
Any fault caused by false usage, imprudence (collision or
inadequate installation) or force majeure factors are not in
Lite-Puter’s service.
Revision Record
Version Record
A First version
H change pictures
I change pictures,1-1,1-4
Issued on: May, 2010
Other manuals for DX-610
1
This manual suits for next models
1
Table of contents
Other Lite-Puter Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Lampo
Lampo LED300IP20RGBW24 instruction sheet

PROGTECH Lighting
PROGTECH Lighting MINI SAFE EVO user manual

Indigo
Indigo OU41324 instructions

Glow Bricks
Glow Bricks Lego LandRover Classic Defender 90 10317 installation guide

Spectroline
Spectroline TRITAN 365 AC Series manual

Digilin
Digilin Edge 20 installation guide