manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LLURIA
  6. •
  7. Control System
  8. •
  9. LLURIA DE-5-DMX-6A User manual

LLURIA DE-5-DMX-6A User manual

Popular Control System manuals by other brands

Comunello BORDER 400 Installation and user manual

Comunello

Comunello BORDER 400 Installation and user manual

Verlinde EUROBLOC Variator VTN Service manual

Verlinde

Verlinde EUROBLOC Variator VTN Service manual

Diginet DGOZ-TCSW-LR35 installation guide

Diginet

Diginet DGOZ-TCSW-LR35 installation guide

VADDIO ControlVIEW Xtreme manual

VADDIO

VADDIO ControlVIEW Xtreme manual

Duke HSHU 13 SERIES Installation and operation manual

Duke

Duke HSHU 13 SERIES Installation and operation manual

AIRTRONICS Blazer Sport manual

AIRTRONICS

AIRTRONICS Blazer Sport manual

Pentair Pool Products Compool Installation and user guide

Pentair Pool Products

Pentair Pool Products Compool Installation and user guide

ComfortNET CTK04 manual

ComfortNET

ComfortNET CTK04 manual

CAME G3000 installation manual

CAME

CAME G3000 installation manual

Idemia MorphoAccess VP MD installation guide

Idemia

Idemia MorphoAccess VP MD installation guide

Doosan DVF Series Operation user's manual

Doosan

Doosan DVF Series Operation user's manual

Axis P1445-LE-3 user manual

Axis

Axis P1445-LE-3 user manual

CNC-Step High-Z T-Series operating instructions

CNC-Step

CNC-Step High-Z T-Series operating instructions

Honeywell KAP 140 Maintenance manual

Honeywell

Honeywell KAP 140 Maintenance manual

Honeywell vk41 series Handbook

Honeywell

Honeywell vk41 series Handbook

Cypress HHR-3160 product manual

Cypress

Cypress HHR-3160 product manual

Zonex GEN II -VVT Installation and application manual

Zonex

Zonex GEN II -VVT Installation and application manual

Altronics K 9650 quick start guide

Altronics

Altronics K 9650 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1/5
v.2022.01
DMX
DE-5-DMX-6A
Sistemas de control
Control systems
Convertidor de 5 canales compatible con señal DMX512 para pasar
a PWM. Posibilidad de seleccionar dirección DMX a través de la
pantalla. Posibilidad de seleccionar con el botón 25 escenas que
incluyen cambios de color y colores jos.
5 channels converter, compatible with DMX512 signal for conversion
to PWM. Option of selecting DMX address via display. Option of using a
button to select dierent scenes that include changes in colour and static
colours.
DE-5-DMX-6A
·Medidas
Dimensions
Características técnicas
Technical data
IP 20
Voltaje entrada Input voltage DC 12/24V
Voltaje salida Output voltage DC 12/24V
Corriente Current 5x6A
Potencia Power 5x72W / 5x144W
Temperatura funcionamiento Operating temperature -30~55ºC
Temperatura almacenamiento Storage temperature -40~80ºC
170mm 40mm
80mm 86mm
Lluria se reserva el derecho de modicar las especicaciones.
Lluria reserves the right to modify specications.
2/5
v.2022.01
·Estructura
Structure
·Esquema instalación
Installation diagram
XLR3 female
DMX signal
XLR3 male
DMX signal
170,00mm
39,50mm
RJ45 DMX signal
GND
(-) LED- Cool White
GND
(-) LED- Green
DMX (-)
DMX (+)
(-) LED- Warm White
DMX AMP (-)
(-) LED- Red
(-) LED- Blue
DMX AMP (+
)
(+) LED
(+) LED
(+) Power input
(-) Power input
86,00mm
80,00mm
DE-5-DMX-6A
DMX Converter 5 channels
Temp Range: -30ºC ~ +55ºC
Quick self- testing: Long press M& >key for 3s
DMX decoder mode: 1-5CH, 8bit / 16bit
DMX master mode: 5CH Dimmer / RGB Controller
DMX signal amplify
Output PWM frequency: 250Hz, 500Hz, 8KHz
Output dimming curve: Gamma 0.1- 9.9
(+)12V/24V
DMX
DMX
3
DMX
2
~220V
POWER SUPPLY
DE-5-DMX-6A
DMX
3
DMX
Signal Female DMX
Signal RJ45
1
DMX
IN/OUT
DMX
Signal Male
OUTPUT
1
LED
(-)12V/24V
2
INPUT
12 - 24VDC
DMX AMP
Lluria se reserva el derecho de modicar las especicaciones.
Lluria reserves the right to modify specications.
DMX
DE-5-DMX-6A
Sistemas de control
Control systems
3/5
v.2022.01
·Funcionamiento
Operation
·Modo decodificador DMX
DMX decoder mode
·Modo master DMX como dimmer 5 canales
DMX master mode as 5 channel dimmer
· Pulsación corta “M”: Cambiar a modo decodicador DMX, modo atenuación y modo controlador RGB.
Short press “M”, switch between DMX decoder mode, Dimmer mode and RGB controller mode.
· Pulsación larga“M” o pulsación corta “< o >”: ingresar estado de conguración del parámetro.
Cuando esté en el estado de conguración de parámetros, presione brevemente la tecla“M”para cambiar entre
varios elementos de parámetro, presione la tecla “< o >” para ajustar los parámetros.
Long press “M” or short press “< or >”, enter parameter setting state.
When in parameter setting state, short press “M” to switch between multiple parameter item, press “< or >” for
parameter adjustment.
· Mantener presionada“M” o esperar 30s: Salir del estado de conguración de parámetros.
Long press M key or wait 30s to quit parameter setting state.
· Presionar“M & >” durante 2s: Autoprueba rápida.
Long press “M & >” for 2s, enter fast self-testing.
· Presionar“< & >” durante 2s: Restaurar parámetro predeterminado de fábrica.
Long press “< & >” for 2s, restore factory default parameter.
Se asigna la dirección del primer canal y se asigna el número de canales según tira de LED utilizada:
The address of the rst channel is assigned and the number of channels is assigned according to the LED strip used:
1CH (DIM) 2CH (CCT) 3CH(RGB) 4CH(RGBW) 5CH(RGB+CCT)
Se puede variar la frecuencia en Hz (señal PWM) para disminuir el icker. Esta acción genera pérdida en la potencia
de salida.
You can vary the frequency in Hz (PWM signal) to decrease the icker. This action causes a loss in power output.
· Se controlan de manera independiente los 5 canales con valores de 0-255 para la intensidad de cada canal.
The 5 channels are controlled independently with values from 0-255 for the intensity of each channel.
DMX Decoder
Addrs: 001 5CH
PwmHz: Std 8bit
Curve: Standard
Dimmer
Ch1: 255 Ch2: 255
Ch3: 255 Ch4: 255
Ch5: 255 All : 255
Lluria se reserva el derecho de modicar las especicaciones.
Lluria reserves the right to modify specications.
DMX
DE-5-DMX-6A
Sistemas de control
Control systems
4/5
v.2022.01
·Modo master DMX como programador RGB
DMX master mode as RGB controller
·Análisis y solución de problemas
Malfunctions analysis & troubleshooting
RGB Controller
05 RGB jump
Spd: 7 Brt: 100%
Ch4: 255 Ch5: 255
· Controla hasta 25 escenas pregrabadas. Se puede variar la velocidad de la escena, la intensidad del 10 al 100% y
permite añadir, a las escenas, los 2 canales CCT de manera independiente, con valores de 0-255 cada uno.
Control up to 25 pre-recorded scenes. You can vary the speed of the scene, the intensity from 10 to 100% and it allows adding,
to the scenes, the 2 CCT channels independently, with values of 0-255 each.
Mal funcionamiento
Malfunctions
Causas
Causes
Soluciones
Troubleshooting
Sin luz
No light
1. Sin alimentación
No power
2. Conexión incorrecta o insegura
Wrong connection or insecure
1. Comprobar alimentación
Check the power
2. Comprobar la conexión
Check the connection
Color incorrecto
Wrong colour
1. Conexión incorrecta de cables R, G, B, W
Wrong connection of R, G, B, W wires
2. Error de dirección decodicación DMX
DMX decode address error
1. Reconectar los cables R, G, B, W
Reconnect R, G, B, W wires
2. Congure la dirección de decodicación correcta
Set correct decode address
Intensidad desigual en inicio y nal de
tramo (caída de tensión)
Uneven intensity at the beginnind and end of
the section (voltage drop)
1. El cable de salida es demasiado largo
Output cable is too long
2. La sección del cable es demasiado pequeña
Wire section is too small
3. Sobrecarga de la fuente de alimentación
Overload beyond power supply capability
4. Sobrecarga en el controlador
Overload beyond controller capability
1. Reducir la longitud del cable
Reduce cable
2. Cambiar cable a sección más grande
Change wider wire
3. Reemplazar la fuente de alimentación a una superior
Replace higher power supply
4. Agregar un repetidor de potencia
Add power repeater
Lluria se reserva el derecho de modicar las especicaciones.
Lluria reserves the right to modify specications.
DMX
DE-5-DMX-6A
Sistemas de control
Control systems
5/5
v.2022.01
Advertencias
Warnings
· La instalación y el mantenimiento del convertidor la deberá realizar personal cualificado.
· Este convertidor no es estanco, en instalaciones de exterior o con humedad deberá ir instalado en cajas estancas.
· La instalación en sitios con buena ventilación prolongará la vida útil del convertidor.
· Compruebe que la tensión de entrada y de salida están dentro de los parámetros indicados.
· Los picos de tensión pueden causar daños en el convertidor.
· Asegure que el cable utilizado en la instalación es de tamaño adecuado.
· Asegure que el cable hace contacto correctamente con el conector.
· Asegure que todas las conexiones de cable y las polaridades son correctas antes de conectar la alimentación.
· The installation and maintenance of the converter must be carried out by qualified personnel.
· This converter is not watertight, in outdoor installations or with humidity it must be installed in watertight boxes.
· Installation in well ventilated areas will prolong the life of the converter.
· Check that the input and output voltage are within the indicated parameters.
· Voltage peaks can cause damage to the converter.
· Ensure that the cable used in the installation is of adequate size.
· Ensure that the cable makes proper contact with the connector.
· Ensure that all cable connections and polarities are correct before turning on the power.