manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LockMasters
  6. •
  7. Lock
  8. •
  9. LockMasters LOCKONE LKM10K User manual

LockMasters LOCKONE LKM10K User manual

Other LockMasters Lock manuals

LockMasters X-Lock X-O7 User manual

LockMasters

LockMasters X-Lock X-O7 User manual

LockMasters LockOne LKM7000 User manual

LockMasters

LockMasters LockOne LKM7000 User manual

LockMasters Kobra Reader GM 10 Cut User manual

LockMasters

LockMasters Kobra Reader GM 10 Cut User manual

Popular Lock manuals by other brands

Magic 105 manual

Magic

Magic 105 manual

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Gantner

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Dorma Studio Classic Installation instruction

Dorma

Dorma Studio Classic Installation instruction

Securam ECSL-601 quick start guide

Securam

Securam ECSL-601 quick start guide

Sudhaus 3003 operating manual

Sudhaus

Sudhaus 3003 operating manual

Safety 1st 48517 user guide

Safety 1st

Safety 1st 48517 user guide

Pado FDS-10 user manual

Pado

Pado FDS-10 user manual

Esco systeQ Series installation instructions

Esco

Esco systeQ Series installation instructions

COMPX National D8951 instruction sheet

COMPX

COMPX National D8951 instruction sheet

secureo Key Box instruction manual

secureo

secureo Key Box instruction manual

Stock Loks C8713 instruction sheet

Stock Loks

Stock Loks C8713 instruction sheet

COMPX 1T-058 Information

COMPX

COMPX 1T-058 Information

Auslock T11 user manual

Auslock

Auslock T11 user manual

Stealth SAFES ShadowVault Instructions & Troubleshooting

Stealth SAFES

Stealth SAFES ShadowVault Instructions & Troubleshooting

Knox KeySecure 5 Admin & user guide

Knox

Knox KeySecure 5 Admin & user guide

Kwikset 48334/01 Quick installation guide

Kwikset

Kwikset 48334/01 Quick installation guide

Metra Electronics Door Access Terminal Combo Technical manual

Metra Electronics

Metra Electronics Door Access Terminal Combo Technical manual

Kilitronik miniK10m operating manual

Kilitronik

Kilitronik miniK10m operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ENTRY
Open the combination lock by
dialing the combination until the lock bolt
is retracted. The dial will come to a dead stop.
Note: See the manufacturers’ operating/programming
instructions for dialing procedures and programming
features for the combination lock.
Leave the combination lock in the open position. (The lock
bolt for the combination lock is within the LKM10K and is not
the latch that can be seen from outside the lock).
If the door does not have secondary electronic access control
and the combination lock has been opened, The LKM10K
will remain locked until the key is inserted into the Key
Override cylinder and turned in either direction. With the
key turned the external lever handle can be turned up or
down to retract the deadbolt and open the door. The key
can be removed once the door is open and will relock once
the door closes and latches. Essentially the Key Override
can act as a manual access control.
2101 John C. Watts Dr.
Nicholasville, Ky 40356
800-654-0637 • 859-885-6041
www.lockmasters.com • www.LKM10K.com
LKM10KHOPINST Copyright © Lockmasters, Inc. Feb 2018
Shown with the Kaba Mas X10
The Key Override Escutcheon
installation will vary depending on
the Fire Rating on the door.
The Light Indicator can NOT be
installed on Fire Rated Doors.
The Light Indicator can ONLY
be installed in the Key Override
Escutcheon on Non-Fire Rated
Doors.
Therefore, you will only see a “green”
light after the access control badge
has been accepted above the key
cylinder on Key Overrides installed
on Non-Fire Rated Doors.
Using Key Override
Operating Instructions for the
LKM10K Push Pull Handle Model
with a Kaba Mas X-10 and Key Override
Standard Key Override Escutcheon
for use on FIRE RATED DOORS
Key Override Escutcheon with
Light Indicator for use on
NON-FIRE RATED DOORS
L
If electronic access control is present – the combination
lock bolt must be retracted first and then present the badge
and/or PIN.
After the access control badge has been accepted a green
light above the key cylinder will illuminate as an indication
that the lock is unlocked (If the Key Override Light Indicator
is installed, see back page).
The external lever handle can be turned up or down to
retract the deadbolt and open the door.
Note: The access control can be used as the daytime
lock while the space is occupied, the combination lock can
remain in the retracted position during operating hours.
Once the door closes and the lock bolt extends, the access
control will relock and secure the door.
Key Override
In the event of a power failure, emergency or access
control failure, the Key Override will let the user override
the access control to gain access to the area. Keep in
mind the combination lock must be unlocked first before the
key override can be used. In order to secure the area after
operating hours, the combination lock bolt must be spun off.
After this has been done the electronic access control or
Key Override will no longer allow the user to open the door
without dialing the combination first.
If the lever handle is turned with the lock bolt extended or
the access control system was not used or timed out, as a
protective measure the handle’s internal clutch will prevent
damage to the lock. It may be necessary to return the
handle to the home position if this condition occurs.
Note: Front lever handle shown in the home position.
EXIT
Single motion
egress is always
possible with a push or
pull of the handle on the back
of the lock. A luminescent push or
pull sticker tells what motion is needed to
unlock the lock and open the door.
No matter what condition the combination lock or access
control system is in (locked or unlocked), exiting the area is
never impeded.
Combination Lock Change Key Access
A change key hole is located on the back cover of the
LKM10K for easy access to the combination lock’s change
key receptacle. Remove the black plug to reveal the
receptacle and follow the manufacturer’s instruction for
changing the combination.
Once the combination has been changed, replace the
change key hole plug.
Operating Instructions for the
LKM10K Push Pull Handle Model
with a Kaba Mas X-10 and Key Override