Lofa CANplus 1000 User manual

CANplus®1000 Control Panel Operation Manual
December 2019
LOFA Document No. 463-3002-59

Disclaimer: The contents of this document are not to be used for advertising, publication, or promotional purposes. Citation
of trade names does not constitute an official endorsement or approval of the use of such commercial products. All product
names and trademarks cited are the property of their respective owners.
DESTROY THIS DOCUMENT WHEN NO LONGER NEEDED. DO NOT RETURN IT TO THE ORIGINATOR.

Table of Contents
1 Important Safety and Emissions Information .......................................................... 1
1.1 Safety Symbols ............................................................................................ 1
1.2 Safety Instructions ........................................................................................ 1
1.3 Auxiliary Engine Stop Disclaimer...................................................................... 2
1.4 General Emissions Disclaimer ......................................................................... 3
1.5 Exhaust Emissions Compliance Disclaimer ........................................................ 3
2 Overview ........................................................................................................... 4
3 Display .............................................................................................................. 5
3.1 Button Bar ................................................................................................... 5
3.2 Gauge Pages ............................................................................................... 6
3.3 Status and Autostart Gauge ............................................................................ 7
3.4 Autostart and Throttling Dashboards ................................................................. 7
3.4.1 Autostart ............................................................................................. 7
3.4.2 Throttling ............................................................................................. 8
3.5 Active Alarms............................................................................................... 9
3.6 Alarm List.................................................................................................... 9
3.7 Service Timers ............................................................................................ 10
3.8 Menus ....................................................................................................... 10
3.8.1 Menu Tree........................................................................................... 11
3.8.2 Access Levels ...................................................................................... 17
3.8.3 Quick Access Menu................................................................................ 18
4 Engine Setup..................................................................................................... 19
4.1 Electronically Governed Engines ..................................................................... 19
4.2 Mechanically Governed Engines ..................................................................... 19
5 Manual Operation............................................................................................... 21
5.1 Throttle Control ........................................................................................... 21
5.2 Ramp Throttle ............................................................................................. 21
5.3 Rotary Throttle Control.................................................................................. 22
5.4 Stopping the Engine ..................................................................................... 22
6 Autostart Operation............................................................................................ 23
6.1 Prerequisites............................................................................................... 23
6.2 Enabling Autostart........................................................................................ 23
6.3 Autostart Menu............................................................................................ 23
6.4 Behavior .................................................................................................... 24
6.4.1 Configuring Operation ............................................................................. 24
6.4.2 Configuring Start and Stop Events .............................................................. 24
Page ii LOFA document No. 463-3002-59 Page ii

6.4.3 Configuring the Transducer ....................................................................... 26
6.4.4 Configuring Start and Stop Delays .............................................................. 28
6.4.5 Ramp Profile........................................................................................ 29
6.4.6 Configuring RPM and Time Profile Settings .................................................... 30
6.5 Transducers................................................................................................ 30
6.5.1 Autostart Triggers .................................................................................. 30
6.5.2 Setup ................................................................................................ 30
6.6 Scheduler................................................................................................... 31
6.7 Timed Run ................................................................................................. 32
7 Configuration .................................................................................................... 33
7.1 Display Menu .............................................................................................. 33
7.2 LOFA CANplus®Customizer Software Suite and LOFA CANplus®Config Kit ........... 33
7.3 LOFA CANplus®Customizer Software Suite and a USB drive ............................... 34
8 Firmware Update ............................................................................................... 35
8.1 Updating via USB drive ................................................................................. 35
8.1.1 Preparation ......................................................................................... 35
8.1.2 Procedure ........................................................................................... 35
9 Miscellaneous ................................................................................................... 36
9.1 Emissions System Functionality ...................................................................... 36
9.2 CP1000 Panel Wiring ................................................................................... 36
9.2.1 Typical J1939 Wiring Topology ................................................................... 36
9.2.2 Engine Harness Connector ....................................................................... 37
9.2.3 Sealed Connectors ................................................................................ 37
9.2.4 Unsealed Connectors ............................................................................. 37
9.2.5 Harness Routing ................................................................................... 39
9.3 Engine Starter Excitation Connection ............................................................... 39
9.3.1 Starter Relay........................................................................................ 39
9.3.2 Battery Circuit Requirements..................................................................... 39
9.3.3 Battery Positive Connection ...................................................................... 39
9.3.4 Voltage Drop ........................................................................................ 40
9.3.5 Suppression of Voltage Transients (Spikes) .................................................... 40
9.3.6 Welding on Equipment with Electronic Controls ............................................... 40
9.4 Control System Troubleshooting...................................................................... 41
9.4.1 Testing a Warning or Shutdown .................................................................. 42
9.4.2 Testing CAN ........................................................................................ 42
9.5 Diagnostic Trouble Codes (DTC) ..................................................................... 42
9.5.1 Typical SPNs ....................................................................................... 42
9.5.2 FMI................................................................................................... 42
LOFA document No. 463-3002-59 Page iii

This page has been intentionally left blank.

1. Important Safety and Emissions Information
1 Important Safety and Emissions
Information
1.1 Safety Symbols
This manual uses the following conventions to present IMPORTANT SAFETY INFORMATION to you.
Please read and follow ALL SAFETY INSTRUCTIONS.
IMPORTANT AND URGENT SAFETY INFORMATION - A HAZARD THAT
WILL, IF NOT AVOIDED, CAUSE SERIOUS INJURY OR LOSS OF LIFE.
IMPORTANT SAFETY INFORMATION - A HAZARD THAT
MIGHT
CAUSE
SERIOUS INJURY OR LOSS OF LIFE.
ADDITIONAL IMPORTANT INFORMATION
1.2 Safety Instructions
Please read and follow all safety instructions.
This document must be completely read and understood prior to installing,
testing, or operating the equipment described within. Further, this document
must be retained for current and future users of this equipment. Failure to
strictly follow the warnings and dangers presented within this document
could result in damage to equipment, damage to property, bodily injury or
death.
LOFA products are not designed or approved for use as critical components
of any safety device or system that is intended to prevent bodily injury,
protect life, or prevent property damage.
LOFA document No. 463-3002-59 Page 1

1. Important Safety and Emissions Information
The specifying Original Equipment Manufacturer (OEM) and/or installer of
any LOFA panel is responsible for all safety labeling and operator education
regarding the safe operation of this panel and the operation of the specific
machine that this panel is installed upon including conformance to exhaust
emissions regulations.
LOFA products are not designed for, or intended for use on, applications
requiring explosive proof components. Further, LOFA products are not
designed for, or intended for application within, hazardous or explosive
environments.
The installer of this LOFA product is solely responsible for ensuring that
all OSHA, ANSI, CE, or other applicable standards are met with respect
to LOFA panel applicability, machine guarding, general safety guidelines,
labeling, and warnings.
The installer of this LOFA panel and/or LOFA harness is responsible for the
correct sizing and integration of a suitable fuse/breaker on the un-switched
DC circuit supplying power to the LOFA panel.
Only trained and qualified persons may perform installation, testing, service,
or repair work on the LOFA product.
The seller hereby expressly disclaims all warranties, either expressed or
implied, including any implied warranty of merchantability or fitness for a
particular purpose, and neither assumes nor authorizes any other person
to assume for it any liability in connection with the sale of such products.
Please refer to www.LOFA.net for details on LOFA Industries, LLC warranty
policies.
LOFA Industries, LLC has provided this document as a reference. We
try to keep this document updated with the latest information regarding
your LOFA product. However, changes do occur and LOFA reserves the
right to make changes to the design of the LOFA products and supporting
documentation without notice.
Page 2 LOFA document No. 463-3002-59 Page 2

1. Important Safety and Emissions Information
1.3 Auxiliary Engine Stop Disclaimer
This panel or harness may include an optional Auxiliary Engine Stop feature.
Please note that
the Auxiliary Engine Stop feature is NOT intended to function as the machine/equipment
Emergency Stop or be purposed as an Emergency Stop for safety purposes.
The machine
manufacturer must provide a separate Emergency Stop switch to meet safety mandates or emer-
gency machine shutdown functionality. The sole design intent of the Auxiliary Engine Stop Feature
is to provide for engine shutdown in the event of a keyswitch malfunction. The panel key/lever switch
should always be used as the primary engine shutdown method.
1.4 General Emissions Disclaimer
This panel may include provision(s) for operator input such as FORCE REGENERATION, INHIBIT
REGENERATION, INTERLOCK, and others specific to US and International emissions regulations.
Responsibility for emissions-related inputs and compliance with emissions regulations is solely that
of the owner and/or operator of the machine/engine on which this panel is connected.
1.5 Exhaust Emissions Compliance Disclaimer
This panel is equipped with operator-programmable parameters. The engine/machine as a function
of the emissions system can/could initiate, via the engine ECU (engine control unit), certain required
emissions operations such as regeneration of the DPF (diesel particulate filter), or other emissions
system maintenance, while the engine is running. The owner/operator of the engine/machine is
solely responsible for any adverse effects or damage to the engine, engine emissions system, or
other damage that could occur as a result of starting or stopping the engine/machine during any
ECU initiated emissions event.
LOFA document No. 463-3002-59 Page 3

2. Overview
2 Overview
The LOFA CP1000 control panel is a manual and autostart platform for EPA Tier 3, EPA Tier 4
(interim), EPA Tier 4, and EU Stage V electronically governed diesel or natural gas engines. It can
also can control mechanically governed diesel engines. Graphical quad-gauge pages are displayed
on the 4.3-inch diagonal WQVGA (480x272 pixels) LCD. Virtually any SAE J1939 parameter reported
by the ECU (Engine Control Unit) can be displayed including, but not limited to: RPM, coolant
temperature, oil pressure, engine hours, voltage, exhaust emissions system state, and diagnostic
codes. The backlit display is clearly readable in both bright sunlight as well as total darkness and
housed in a rugged IP66 rated housing. The CP1000 has three (3) bright LEDs to indicate Faults
and Warnings, Emission-Related Alerts, and Autostart active. The Panel has five (5) display keys
that are associated with the dynammic Display Key bar and eight (8) control buttons.
The CP1000 panel features advanced automatic start/stop control which can meet almost any
requirement. Building on the functionality of the CP750 series platform, this next generation panel
offers many new start/stop modes using a very powerful, yet easily configured Event Manager, which
can start or stop based on any of the eight (8) digital inputs, six (6) 4-20mA analog transducer
inputs, Real Time Clock, or combinations of date/time and analog or digital inputs. With the use of a
transducer, the panel has a ”crusie control” feature that automatically throttles the engine to maintain
a configurable level. The panel can be configured to use any one of the transducer inputs for the
maintain/cruise control feature regardless if that input is also being used as a start or stop event.
All components are installed in a heavy-duty, vibration-isolated metal or NEMA-rated plastic enclosure
designed to withstand the most extreme industrial applications. External weather resistant switches
and controls facilitate convenient operator inputs/controls. Active fault conditions are displayed in
plain language on popup messages and can be viewed in the fault list. Various diagnostic screens
allow detailed investigation of the CAN bus data stream.
All diagnostic and emissions related messages displayed on the CP1000 are generated by the
engine ECU or other attached devices. The operator must be familiar with the engine manufacturer
ECU messages and icons in order to react accordingly with respect to emissions compliance, service,
and diagnostic message response.
Page 4 LOFA document No. 463-3002-59 Page 4

3. Display
3 Display
The CANplus
®
display is a robust, sunlight viewable 4.3” WQVGA color display with five (5) integrated
backlit display buttons and eight (8) large control buttons housed in a rugged, water-tight IP66 rated
enclosure. The five display keys simplify and enhance the user interface by providing positive tactile
feedback when pressed. The display can show virtually any SAE J1939 parameter reported by
the ECU, including RPM, engine temperature, oil pressure, and diagnostic codes. It can be easily
configured to customer preference, including gauge type (analog or digital), gauge arrangements,
gauge size, units, and language.
Different software versions may have slightly different displays.
LOFA document No. 463-3002-59 Page 5

3. Display
3.1 Button Bar
Pressing any of the first five (5) soft keys on the display will prompt the ”button bar” key function
legend to appear at the bottom of the display above the keys. The button bar will show an icon above
the button which corresponds to its current function.
Button 1 Button 2 Button 3 Button 4 Button 5
Analog Gauge
Pages
Digital Gauge
Pages
Single Analog
Gauge
Active Alarm
Page
Menus
Each press
cycles through
the four pages of
analog gauges
Displays the
Database Viewer
Displays
Emission Control
menus
Displays active
alarms including
plain language
description
Opens Menus
3.2 Gauge Pages
There are four (4) independently configurable pages of analog gauges. To enable Analog Gauge
Pages, press any of the first four (4) buttons to show the top level button bar and then press button 1
to cycle through the pages. The current page is indicated by the number in the center of the screen.
Page 6 LOFA document No. 463-3002-59 Page 6

3. Display
Some items like Engine Hours are displayed only as a digital value.
All sixteen (16) gauges may be configured to create an application-specific view of data. With Tech
or Admin level access, the four (4) gauge pages can be configured using the menu
Configuration
Display Gauges Quad Gauge Pages .
3.3 Status and Autostart Gauge
To the left of the configurable gauges is the Status gauge (top left) and the Autostart gauge (bottom
left).
The Status gauge shows the status of many of the emissions-related features as well as date, time,
signal strength.
The Autostart gauge shows the start and stop events or levels on the left and the maintain/cruise
control level on the right.
3.4 Autostart and Throttling Dashboards
3.4.1 Autostart
LOFA document No. 463-3002-59 Page 7

3. Display
Click here to view the autostart dashboard video.
When the Dashboard-1 button is pressed, the display will change to the full screen Autostart
dashboard.
When the Dashboard-1 button is pressed again, the display will revert back to the gauge page.
3.4.2 Throttling
When the Dashboard-2 button is pressed, the display will change to the dashboard.
Page 8 LOFA document No. 463-3002-59 Page 8

3. Display
Pressing the Dashboard-2 button again will cause the display to revert back to the gauge page.
3.5 Active Alarms
When an active alarm is received, a flashing popup window is overlaid on the current screen. The
popup includes a plain language description in addition to the standard SPN/FMI (Suspect Parameter
Number/Failure Mode Indicator) pair defined by the SAE J1939 standard. Additionally, if enabled,
the beeper sounds as an audible cue.
Standard J1939 abbreviations are used for alarms. MS = Most Severe,
MOD = Moderately Severe, LS = Least Severe.
3.6 Alarm List
The Alarm List is accessed by pressing any button while an alarm popup is displayed or by pressing
any of the first 4 buttons to show the button bar and then button 4. Alarms not yet acknowledged are
shown in white on red while acknowledged alarms are shown in white on black. The list also indicates
when the alarm occurred if engine hours are available. The most recent alarm is displayed at the
top of the list. The list can be scrolled using buttons 1 and 2 and alarms acknowledged by pressing
button 3. The Alarm List can be closed by pressing button 5 once the alarms are acknowledged.
An alarm indicator is displayed near the upper right corner of the display as long as alarms are
active. The indicator and alarm messages in the list are automatically removed when the alarm has
not been received for a few seconds.
LOFA document No. 463-3002-59 Page 9

3. Display
3.7 Service Timers
Once an alarm is silenced using the center display button, a QR-code icon will appear on this
button. This button provides access to LOFA’s Equipment Fault Code Diagnostic Information system
(www.lofa.net/Patents). Pressing this button again displays a QR-code specific to this alarm. The
QR-code can be scanned using the camera on most smart phones. When scanned, the phone
will give an option to automatically jump to LOFA’s RemoteIQ (RiQ) Fault website. The website will
automatically pull up the details for this particular fault and possible remedies.
The panel’s display provides sixteen (16) service timers to alert the operator of required maintenance.
The time interval for each timer can be adjusted in increments of ten (10) hours. A popup message
is displayed after the display’s self-test if a timer (or timers) has expired alerting the user that service
is required. The message is displayed on each power up until the elapsed timer is disabled or
reset. The service timers can have their respective names customized to monitor engine- and
machine-related parameters. All sixteen (16) service timers can be monitored via wireless telemetry.
Only active faults are displayed in the alarm list. Once a fault is corrected it
is automatically removed from the list. To view previously active faults press
the ”STORED” button.
3.8 Menus
The menu pages can be accessed by pressing button 5. The top-level menu page will then appear.
From there the functions of the five display buttons change to allow navigation and selecting and
modifying parameters.
Page 10 LOFA document No. 463-3002-59 Page 10

3. Display
Button 1 Button 2 Button 3 Button 4 Button 5
Sroll Up Scroll Down [Intentionally
Blank]
Go into Selected
Submenu
Return to
Previous Menu
Decrement Value Increment Value
or or
Previous
Selection
Next Selection
3.8.1 Menu Tree
The menu tree is shown below. Some menus items are suppressed based on the access level
currently allowed. The color of the text in the tree indicates the minimum access level required for
this particular item to be available for displaying.
Black = User
Green = Tech
Red = Admin
Display
• Language
• Units
–Distance
–Pressure
–Volume
–Temperature
•Gauges
–Quadrant Page 1-4
*Top Left
*Top Right
*Bottom Left
*Bottom Right
•Power Timeout
LOFA document No. 463-3002-59 Page 11

3. Display
System Setup
•Restore Defaults
• Set Date & Time
•Import Configuration)
• Export Configuration
•Load Firmware
•Bootloader Update
• PINs
–Elevate Access Level
–Change
–Entry Off/On
•Engine
•Engine Specific Settings
–Starter
*Running Threshold
*Max Starter On (s)
*Min Starter On (ms)
*Dropout RPM
*Restart Delay (s)
*Restart Attempts
–Engine Data Sources
*Tachometer
*Engine Hours
*Coolant Temp
*Oil Pressure
–Mechanical Engines
*Calibrate Tach
*Actuator Setup
*Preheat
·Mode
·Duration
·After Glow
·Enabled During Cranking
–Yanmar
–CAT / Perkins
–[Future Engines]
• About
Page 12 LOFA document No. 463-3002-59 Page 12

3. Display
Telemetry
Emission Control
• Request Force Regen
• Inhibit Regen Disable/Enable
Throttle
•Minimum RPM
• Idle RPM
•Maximum RPM
• Switch/Rotary
–Switch RPM
–Increment
–Rotary RPM
–Increment
–Max RPM
–Change / sec
Autostart
• Behavior
–Operation
*High→Low
*Low→High
–Start-Stop With
*
Dual Switch, Single Switch, Transducer, Transducer w/ Backup Switches, Scheduler
Only, Timed Run, Cycle Run, Single Start/Stop, Remote Control, Pressure Washer
–Start Enable Delay (s)
–Stop Enable Delay (s)
–Maintain Transducer
*Maintain Function
· Disable
· Low→High
· High→Low
*Auto Throttle Input
· Transducer 1,2,3,4,5,6
*Target Point
*Throttle Aggressiveness
*Error Operation
· Controlled Stop, Immediate Stop, Go to Run, Derate
•Ramp Profile
LOFA document No. 463-3002-59 Page 13

3. Display
–RPM Settings
*Intermediate RPM
*Run RPM
–Time Profile
*Warm Up Time (s)
*Ramp Up (s)
*Intelligent Intermediate
*Intermediate (s)
*Ramp to Run (s)
*Ramp Down (s)
*Cool Down (s)
• Transducer
–Autostart Trigger
*Autostart Trigger
· Transducer 1,2,3,4,5,6
*High Set Point
*Low Set Point
–Setup
*Transducer 1-6
· Low Warning Alarm
· Low Shutdown Alarm
· High Warning Alarm
· High Shutdown Alarm
· Type & Range
• Scheduler
–Method
*Allowed Times, Disabled, Override
–Schedule A-P
*Days of the Week
*Start Time hh:mm
*Stop Time hh:mm
• Timed Run
–Default Time hh:mm
–Switch Adjustment hh:mm
• Cycle Time
–Default State
*Stopped, Running
–Run Time hh:mm
–Stop Time hh:mm
•Auto Battery Recharge
Page 14 LOFA document No. 463-3002-59 Page 14

3. Display
–Auto Battery Enabled
*Off/On
–Recharge Run Speed
–Enable Delay (m)
–Recharge Time (m)
–Delay Between Recharge (m)
–Low Battery Threshold (V)
LOFA document No. 463-3002-59 Page 15