manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lovibond
  6. •
  7. Measuring Instrument
  8. •
  9. Lovibond SD 60 REDOX User manual

Lovibond SD 60 REDOX User manual

Other Lovibond Measuring Instrument manuals

Lovibond TR 515 Assembly instructions

Lovibond

Lovibond TR 515 Assembly instructions

Lovibond SWIMTEC MD100 User manual

Lovibond

Lovibond SWIMTEC MD100 User manual

Lovibond Scuba User manual

Lovibond

Lovibond Scuba User manual

Lovibond CheckitDirect User manual

Lovibond

Lovibond CheckitDirect User manual

Lovibond SD 320 Con User manual

Lovibond

Lovibond SD 320 Con User manual

Lovibond Photometer-System MD100 User manual

Lovibond

Lovibond Photometer-System MD100 User manual

Lovibond SensoDirect pH200 User manual

Lovibond

Lovibond SensoDirect pH200 User manual

Lovibond MD200 User manual

Lovibond

Lovibond MD200 User manual

Lovibond MD200 User manual

Lovibond

Lovibond MD200 User manual

Lovibond MD200 User manual

Lovibond

Lovibond MD200 User manual

Lovibond MD 610 User manual

Lovibond

Lovibond MD 610 User manual

Lovibond Photometer-System MD100 User manual

Lovibond

Lovibond Photometer-System MD100 User manual

Lovibond SD 60 User manual

Lovibond

Lovibond SD 60 User manual

Lovibond MicroDirect pH10 User manual

Lovibond

Lovibond MicroDirect pH10 User manual

Lovibond Maxi Direct User manual

Lovibond

Lovibond Maxi Direct User manual

Lovibond RT 400 User manual

Lovibond

Lovibond RT 400 User manual

Lovibond Tintometer SensoDirect Con110 User manual

Lovibond

Lovibond Tintometer SensoDirect Con110 User manual

Lovibond SD 400 Oxi L User manual

Lovibond

Lovibond SD 400 Oxi L User manual

Lovibond ORPTester10 User manual

Lovibond

Lovibond ORPTester10 User manual

Lovibond Photometer-System MD100 User manual

Lovibond

Lovibond Photometer-System MD100 User manual

Lovibond CheckitDirect User manual

Lovibond

Lovibond CheckitDirect User manual

Lovibond Scuba+ User manual

Lovibond

Lovibond Scuba+ User manual

Lovibond SD 400 Oxi L User manual

Lovibond

Lovibond SD 400 Oxi L User manual

Lovibond Tintometer XD 7500 User manual

Lovibond

Lovibond Tintometer XD 7500 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SD %=
pH
SD 60
REDOX
Lock/Unlock Data!
C. Backlight ON/OFF
____________________________________________________________________________________________
Note: Icons/Characters in RED meaning "BLINK"
: Hit once / : Press and hold / : Release
3
F. Store Data
1. In lock mode: 2s
2. In measurement mode: 2s (or 2s )
3. When the storage is full, it will overwrite the oldest data.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
G. System Setup
Menu selection:
2s (latest memory#)
(7.00 or 6.86) (dd-mm-yy/24hr or mm-dd-yy/12hr) (°C or °F)
(31-12 24 or 12-31 12ampm) .....
To enter:
!
MEASUREMENT
ORP CALIBRATION
Characters in RED represent “Flashing symbols“.
Remove protective cap from the probe
D. Store Data
Press
Press for
3 seconds
Press and
hold
+
+
+
1 2 3
4 5 6
+
-
--
-
Insert the batteries
unlock
off
off
unlock
off
Automatically turns off after 20 minutes of
inactivity.
Possible slight delay after pressing
before freeze of the data (!).
After 3 sec. the file no. temporarily appears
on the display, e.g. 01.
Once the storage has reached max. capacity,
the data will overwrite the oldest files.
off
lock
on
on
• Re-Calibrate according to individual recommendations! Rinse the electrode
with distilled water after each measurement.
• Choose Orbeco-Helilge ORP Standard Solution
Remove protective cap from the probe.
Power ON (see A)
Immerse the probe
into calibration
solution.
E. Calibrate ORP
To decrease (-):
Adjustment +
∞
∞
To increase (+):
Max. ± 150 mV of window:
!
wait ( indicates “user calibrated“)
to store
lV. Set Data/Time display type
VI. Electrode Replacement
SETUP
I. Recall Data
II. Set Date and Time
Ill. Set Temperature system (°C/°F)
3 sec
3 sec
3 sec
3 sec
3 sec
3 sec
3 sec
Minutes
Minutes
24 h
AM
PM
Hours
Hours
Year
Year
Month
Day
Day
Month
F. System Setup
Unfreeze data first (see frontside B) before Menu selection.
Delete stored data.
Automatic Exit
Select V. `Set Data/ Time display type‘ first.
to increase (+);
am/pm 12 hour clock
24 hour clock
new electrode
to decrease (-)
am/pm
12 hour clock
or 24 hour
clock
Adjustment:
1x
2x
3x
Press for
further files. Exit
Exit
Exit
Exit
Exit
°C °C
select select
°F
123
4 5 6
Content
1 REDOX/ORP Meter SD 60 in
a robust plastic case
2 Batteries
1 Instruction Manual
Code: L1948 01
Accessories
4000-06 Battery CR 2032 (2 Batteries required)
L194821 Replacement electrode
L384801 Beaker, 100 ml
L195070 Standard solution
SD60 ORP Specication/Features
Characters in RED represent “Flashing symbols“.
Recall Data
go to l.
Set Temperature
go to lV.
Set Data/Time display
type go to V.
Set Date and Time
go to lll.
To enter.
3x
2x
1x
3 sec