Lowell MSM2 User manual

Model: MSM2
Momentary Switch Module
©2010 Lowell Manufacturin Company, 100 Inte ram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—
636.257.6606. Lowell makes every effort to provide accurate information while reservin the ri ht to chan e
specifications and/or improve manufacturin methods without notification. (lowellmf .com)
Spec. No. 1141
(rev. 04.22.11)
pg. 1 of 2
Model No. Description Power Requirements (drawn from host) Remote Switch Maximum
S 2 omentary Switch odule 24VDC, 30mA 6 with RPCs (100mA max) or 12 with SCS-4 (200mA max)
Description:
The momentary switch module ( S 2) allows equipment that’s con-
nected to a remote power control (RPC-series) or 4-step sequencer
(SCS-4) to be switched from multiple locations. The S 2 is placed
between the RPC (or SCS-4) and multiple momentary switches. It
converts the normally open momentary contact closures to latching,
maintained closures. This allows multiple switches in a variety of lo-
cations to activate connected equipment. When the S 2 is con-
nected, a momentary closure on any remote switch causes the S 2
to change the state from open to closed or from closed to open, turn-
ing the RPC (or SCS-4) on or off. The S 2 features dual terminal
strips to connect (2) SPST momentary-style switches. Additional
switches can be added in parallel (6 total for use with RPC-series or
12 total for use with the SCS-4). LED indicators display system sta-
tus (on or off). The S 2 does not require an external power source
as it draws power from the host unit (RPC-series or SCS-4).
Features:
• Compact unit (5"L x 3.279"W x 1.687"H)
• Steel chassis with black powder epoxy finish includes mounting
holes and connection diagram.
• ount to a blank rack panel or rack shelf that’s pre-punched for
electronic devices (Lowell odel No’s. USE-210 or USE-310, order
separately)
• ade in the USA
A & E Specifications:
The device for converting normally open momentary contact closures
to latching maintained closures shall be Lowell momentary switch mod-
ule odel No. S 2. It shall allow for multiple momentary style
switches to be used to activate equipment that is connected to Lowell
RPC-series remote power controls or Lowell SCS-4 sequence con-
troller. The S 2 device shall include 1 terminal strip for connection
to remote power control odel No.______(RPC-series) or sequence
controller odel No. SCS4. It shall also include 2 terminal strips to
connect up to 4 momentary switches odel No.______(RPSB-series)
when connected to a remote control (RPC-series) host; or up to 12
momentary switches odel No._______(RPSB-series) when con-
nected to sequence controller odel No. SCS-4 as a host.
Compatible Remote Switches: (order separately)
Momentary closure switch — three conductors:
RPSB- P ........Black Decora wall plate switch (rocker switch, 1 LED)
RPSW- P .......White Decora wall plate switch (rocker switch, 1 LED)
RPSB- KP......Black Decora wall plate switch (key switch, 1 LED)
RPSW- KP.....White Decora wall plate switch (key switch, 1 LED)
RPSB- R........IU rackmount switch (rocker switch, 1 LED)
RPSB- KR......IU rackmount switch (key switch, 1 LED)
Momentary closure switch — four conductors:
RPSB2- P ......Black Decora wall plate switch (rocker switch, 2 LEDs)
RPSW2- P .....White Decora wall plate switch (rocker switch, 2 LEDs)
RPSB2- KP....Black Decora wall plate switch (key switch, 2 LEDs)
RPSW2- KP...White Decora wall plate switch (key switch, 2 LEDs)
RPSB2- R......IU rackmount switch (rocker switch, 2 LEDs)
RPSB2- KR....IU rackmount switch (key switch, 2 LEDs)
Compatible Host Devices: (order separately)
RPC-1....................................Remote power control (15A, 1 duplex, cord)
RPC-1-20A-CD......................Remote power control (20A, 1 duplex, cord)
RPC-1-20A- C .....................Remote power control (20A, 1 duplex, hardwired)
RPC-1-30A- C .....................Remote power control (30A, 1 twistlock, hardwired)
RPC-1-IG- C........................Remote power control (20A, 1 IG duplex, hardwired)
RPC-1-TVSS-CD...................Remote power control (20A, 1 duplex, cord)
RPC-1-TVSS- C ..................Remote power control (20A, 1 duplex, hardwired)
RPC-4-CD .............................2U rackmount panel with remote control (15A, 4 duplex, cord)
RPC-4- C.............................2U rackmount panel with remote control (15A, 4 duplex, hardwired)
ACS-1510-RPC .....................Power strip with remote control (15A, 5 duplex, cord)
ACS-2010-RPC-HW..............Power strip with remote control (20A, 5 duplex, hardwired)
ACS-2010-IG-RPC-HW.........Power strip with remote control (20A, 5 IG duplex, hardwired)
ACS-2018-5C-RPC-HW ........Power strip with remote control (20A, 9 duplex, 5 circuit, hardwired)
ACS-2018-IG-5C-RPC-HW ...Power strip with remote control (20A, 9 IG duplex, 5 circuit, hardwired)
SCS-4....................................Sequence controller
1.55"
5.00"
4.50"
3.10"
(3) plug-in Phoenix-
style connectors
provided with unit
Terminals will accept
up to 14-ga. wire,
stranded or solid
(2) 7/32"
mounting
holes

Spec. No. 1141
(rev. 04.22.11)
pg. 2 of 2
©2010 Lowell Manufacturin Company, 100 Inte ram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—
636.257.6606. Lowell makes every effort to provide accurate information while reservin the ri ht to chan e
specifications and/or improve manufacturin methods without notification. (lowellmf .com)
Model: MSM2
Momentary Switch Module
Typical application with RPC unit:
Toggle (flip-flop) between two RPC units:
Additional RPC units may be added.
Connect Com and Sw terminals ONLY.
3 conductors*
Connection to RPC-1.
Connections are identi-
cal for all RPC-series .
4 conductors*
3 conductors*
Additional switches
may be added
(max. 6 total).
Note: Two remote switch
terminal blocks are provided
for convenience. Terminals are
parallel connected internally.
Three conductors connect to omentary Switch odels:
RPSB- P
RPSW- P
RPSB- KP
RPSW- KP
RPSB- R
RPSB- KR
Four conductors connect to omentary Switch odels:
RPSB2- P
RPSW2- P
RPSB2- KP
RPSW2- KP
RPSB2- R
RPSB2- KR
SPST normally open momentary
switches (unlimited quantity).
Note: Two remote switch terminal blocks
are provided for convenience. Terminals
are parallel connected internally.
*Note: 22-ga. wire maximum distance 6,000 ft.
18-ga. wire maximum distance 15,000 ft.
Other Lowell Control Unit manuals
Popular Control Unit manuals by other brands

Anritsu
Anritsu MT1000A Network Master Pro Operation manual

Sony
Sony CCP-6224 CCP-6324 MKS-8010B MKS-8011AMKS-8013A MKS-8014A MKS-8015A MKS-8017AMKS-8018A MKS-8019A MKS-8020A... Operation manual

Honeywell
Honeywell VSxF-2 installation instructions

Zander Aachen
Zander Aachen TE-OR3 User information

Pepperl+Fuchs
Pepperl+Fuchs WCS-PNG110 manual

SMC Networks
SMC Networks VFR4000 Series Operation manual