LSIS GIPAM 2000 User manual

1
T
TT
The best choice for your benefit.
he best choice for your benefit.he best choice for your benefit.
he best choice for your benefit.
LSIS makes an effort to give more benefit to user.
The table of contents
The table of contents The table of contents
The table of contents
• The Safety Caution………………………………………·2
1. The layout of MMI………………………………………·4
1-1 The external view
1-2 The menu of GIPAM-2200
1-3 The PASSWORD mode
2. PC interface……………………………………………··28
3. The spec of User Interface……………………………32
3-1 The configuration of terminal block & DI, DO contacts
3-2 The configuration of CT, PT
3-3 The configuration of Digital Input
3-4 The configuration of Digital Input
4. The characteristic curves……………………………··44

2
Safety caution
Safety cautionSafety caution
Safety caution
Please read carefully before product being taken
Please read carefully before product being taken Please read carefully before product being taken
Please read carefully before product being taken
into service to ensure safety and proper operation
into service to ensure safety and proper operationinto service to ensure safety and proper operation
into service to ensure safety and proper operation
of GIPAM2
of GIPAM2of GIPAM2
of GIPAM20
00
000
0000
00.
• Please keep the safety caution to prevent any accident
may happen by using the products incorrectly.
• Safety caution is classified with caution and danger
and indication of them as follows.
Symbols used in this manual indicate as follows.
This instruction shall be kept in the nearest place of GIPAM2200.
Caution
CautionCaution
Caution
Danger
DangerDanger
Danger
Not following the instruction may result in
Not following the instruction may result in Not following the instruction may result in
Not following the instruction may result in
serious injury
serious injuryserious injury
serious injury or even death
or even death or even death
or even death
Not following the instruction may result in
Not following the instruction may result inNot following the instruction may result in
Not following the instruction may result in
serious injury
serious injuryserious injury
serious injury or property damage
or property damage or property damage
or property damage
This
This This
This symbol
symbolsymbol
symbol is for warning the hazardousness
is for warning the hazardousness is for warning the hazardousness
is for warning the hazardousness
under
underunder
under the specific condition
the specific condition the specific condition
the specific condition
.
..
.
This
This This
This symbol
symbolsymbol
symbol is for warning the electric
is for warning the electric is for warning the electric
is for warning the electric shocks
shocksshocks
shocks or
or or
or
any accidents under the specific condition.
any accidents under the specific condition.any accidents under the specific condition.
any accidents under the specific condition.
Caution
• Please do not wiring when applied with power or on the operation;
it may result in electric shock.
• Please do not all the wiring operation with the live bus bar; it may result in electric shock or
fire and property damage by charging voltage of current transformer.
• Please put to earth; it may result in electric shock.
• Please do not attempt to disassemble even when the power not applied; it may result in
electric shock by charging current remained in the product.
• Please do not wire or operate with wet hands; it may result in electric shock.
• Please do not use any damaged cable; it may result in electric shock.
• Please use the ring terminal when wiring the cable; it may result in electric shock by bare wire.

3
Danger
█ Safety caution for installation & terminal wiring
• Apply the rated voltage to the power supply terminal; it may result in property damage or fire.
• Please keep away product from screws, metals, water, or oil; it may result in fire.
• Please keep the rated load and polarity of input & output contacts; it may result in property
damage or fire.
• Please wire to the terminal block after checking the terminal number; it may result in property
damage or fire.
• Specialist help shall be sought for the installation and maintenance of product; it may result in
malfunction or accident.
• Please do not wiring when applied with power or on the operation;
it may result in electric shock.
█ Inspection item before power supply being applied
• Check the voltage or polarity of control power supply.
• Check the wiring condition of input/output terminal.
█ Caution for storage & handling
• Please store at dry & clean place.
• Please do not throw or put force on it during transport; It may result in malfunction or wrong
operation
• Please stock the products in the way of FIFO (First-in First-out).
•
Please do not load over
5
stories.
█ Caution for disposal
•
Please dispose of it in accordance with industrial waste regulation.

4
(PIC 1 : INPUT & OUTPUT interface of GIPAM2000)
1
11
1.
. .
. MMI
MMIMMI
MMI
IrDA
Port
(
Infrared
rays)
Direction
Function
Status LED
Graphic LCD
Trip assign LED
REMOTE/LOCAL
ENTER
CANCLE
CB1 ON/OFF
CB2 ON/OFF

5
1
11
1-
--
- 1
1 1
1 The disp lay window of
The disp lay window of The disp lay window of
The disp lay window of GIPAM
GIPAMGIPAM
GIPAM-
--
-2000
2000 2000
2000
1
11
1.
. .
. MMI
MMIMMI
MMI
1-1-1. LCD
GIPAM-2000 has a 320 x 240 FSTN LCD to display various measurement data, event, and faults
for the user’s convenience. It supports ASCII english text & numbering code and also 20 special
characters. The used fonts are 8 x 12(windows system) and 11 x 18(windows terminal). The
various measurement data, event, and faults are displayed by text and picture on LCD. The
number is decimal system. LCD backlight support users to see the display in dark space. And
the backlight will be turned off by no using for 15 minutes.
LCD display
LCD displayLCD display
LCD display
MENU
MENUMENU
MENU NAME
NAME NAME
NAME
Additional
Additional Additional
Additional Explanation
ExplanationExplanation
Explanation
1-1-2. LCD display components
As above picture, menu name and additional explanation can be located on above and
bellow in case of need.
1-1-3. LED
The LED can be divided into trip assign LED, status LED and expert skill LED.

6
① Trip assign LED - It is with yellow and installed by user.( User can set that LED indicates
what user wants. ) GIPAM-2000 type has 6 LEDs. The LED which corresponds to detected
faults is ON when GIPAM-2000 is tripped due to systematic faults. The LED for protection
relay can be cancelled only by RESET KEY like the PICK-UP/TRIP LED.
② Status LED – GIPAM2000 has 4 status LED.
Power supply LED is with green and indicates the status of power supply of GIPAM-2200.
For normal operation it is kept with green light ON but for the abnormal operation it is
blinking every second.
Communication LED is with orange and indicates the status of remote communication. The
LED is blinking while transmitting or receiving data under normal correspondence of
communication card.
Diagnosis/Error LED is with yellow but it is blinking if problem has found with hardware or
program while it is being under self-diagnosis. Under normal operation it is in OFF. Please
contact the official A/S centre in case of blinking of LED.
PICK-UP/TRIP LED is with red and indicates the protection relay of GIPAM-2200. It is
blinking
every second if protection relay is in the condition of Pick-up by systematic faults. It is kept
with red light ON if it is tripped by the operation of protection relay. This LED can be
cancelled only by RESET KEY of protection relay or reset of it with remote communication.
③ Expert skill LED
REMOTE/LOCAL LED is on the upper side of R/L KEY with green & red and indicates the
present control status of GIPAM-2200. It is with GREEN light ON under REMOTE control
and with RED light ON under LOCAL control. These two LEDs shall not be ON or OFF at
the same time.
CB CLOSE/OPEN LED is on the upper side of CLOSE/OPEN KEY with green & red and
indicates
the present status of circuit breaker which is connected to GIPAM
-
2200
1
11
1.
. .
. MMI
MMIMMI
MMI

7
LED operation Setting
ON Relay trip
Trip assign
OFF OFF in usual
F4 key on relay
setting menu
ON Power on
Power/run OFF Power off
Comm. flickering
It flickers on
communicating
ON Error detection
Diag/err
OFF
Put the F5 key after clear
the reason of error.
(error reset)
ON Relay trip
flickering
The occurrence of relay trip
Trip/pick-up
OFF
OFF in usual.
Put the F5 key after clear
the fault.(reset)
GREEN
Remote mode R/L
(remote/local) RED Local mode
ON CB1 is ON
CB1 ON OFF CB1 is OFF
ON CB1 is OFF
CB1 OFF OFF CB1 is ON
None(default)
ON CB2 is ON
CB2 ON OFF CB2 is OFF
ON CB2 is OFF
CB2 OFF
OFF CB2 is ON
It doesn’t operate
in case that CB2
is set up to PO.
1-1-4. LED setting and operation.
1
11
1.
. .
. MMI
MMIMMI
MMI

8
1
11
1-
--
- 2
2 2
2 The
The The
The input de vice
input de vice input de vice
input de vice of
of of
of GIPAM
GIPAMGIPAM
GIPAM-
--
- 2000
2000 2000
2000
key name Operation
F1
Function key1
Display mimic diagram
F2
Function key2
Display all menu Save the setting
Incident history
Event & fault menu. user can
delete the accumulated data on
Demand menu.
F3
Function key3
measurement Clear the accumulated data
F4
Function key4
Protective relay Set up the trip assign
LED
F5
Function key5
Reset the relay trip or device errors.
R/L Remote/local
Changing the remote/local.
Red is local and green is remote.
E enter Confirming or entering the menu.
C cancel Cancellation or moving to upper menu.
DIRECTIONAL
KEY
- Moving or change the values.
CB1 ON
- CB1 ON
CB1 OFF
- CB1 OFF
CB2 ON
- CB2 ON
CB2 OFF
- CB2 OFF
It doesn’t operate in
case that CB2 is set up
to PO.
1
11
1.
. .
. MMI
MMIMMI
MMI
User can set up or operate GIPAM2000 with front key. Gipam2000 has 16 keys and each
has specific functions
.
If the GIPAM2000 is on the ‘remote’ mode, user can’t control the device by front keys. If
want to control the device, user should set the GIPAM on ‘local’ mode.
All keys operate when user puts the key within 0.2 seconds. And the values of inputs by
keys are not saved on buffer.
※ CB ON/OFF keys don’t operate within 3 seconds after operation of CB. It is for the
protection of mistaken.

9
1
11
1-
--
- 3 IrDA Serial
3 IrDA Serial 3 IrDA Serial
3 IrDA Serial comm
commcomm
comm unicational Device
unicational De vice unicational De vice
unicational De vice (Opto
(Opto(Opto
(Opto-
--
-master)
master)master)
master)
1
11
1-
--
- 4 Tables of ME NU
4 Tables o f MENU 4 Tables o f MENU
4 Tables o f MENU
GIPAM2000 has 5 primary menu. Each menu has upper & lower (detail) menu.
1
11
1.
. .
. MMI
MMIMMI
MMI
GIAPM2000 has IrDA communicational device. (Opto-master). User can connect the RS-
232 Port of Opto-master to PC directly. And can control or monitor the status of GIPAM
with G2K manager program. User can upload or down load data from PC to GIPAM. The
communication speed is 38400bps.
*refer to G2K manual for more info.
Primary menu
model
L
ower
menu
L
ower
menu
1
L
ower
menu
2
remarks

10
1
11
1.
. .
. MMI
MMIMMI
MMI

11
1
11
1-
--
- 5 The function s an d operations of MMI
5 The functions and operations of MMI 5 The functions and operations of MMI
5 The functions and operations of MMI
1
11
1.
. .
. MMI
MMIMMI
MMI
Protective relay
User can set up the relay and change the value on Protective relay menu.
① the components of lower menu.
L
ower
menu

12
② Menu movement and operations of key.
1
11
1.
. .
. MMI
MMIMMI
MMI
M
E
N
U
L
O
W
E
R
M
E
N
U
D
E
T
A
I
L
The primary menu
of GIPAM.
This menu is the
top menu.
This menu displays
the available relay
elements. Y
ou can set
the on/off of the each
relay elements.
You can set up the
detail value setting
each relay on this
menu.
Moving up/down :
Up, down directional
Key.
Moving to lower menu:
Select the menu user
wants and put the enter
key.
Moving menu to menu:
Up, down directional key
Moving to top menu: cancel key
Moving to detail setting menu:
Select the menu user want and
put the enter key.
Select the on/off of relay elements:
Select the relay elements and put
the left/right key.
Moving menu to menu:
Left/right directional key
Moving to upper menu: cancel key
Change the setting values:
Select the menu user want and
put the up/down key.
Save the changed: F2
Set the trip assign LED:F4.
DISPLAY EXPLAN
HANDLING METHOD

13
1
11
1.
. .
. MMI
MMIMMI
MMI
You can see the main menu by pressing the ESC or ENTER key on the primary display.
This main menu displays menu list for movement to child menu.
User can move the curser by pressing the Up, Down directional key and enter the child
menu by pressing ENTER key.
If you want to select/cancel the each relay element. Move curser to target relay element
with Up/Down key and click the Light/Left key. And it will display confirmation question to
user. ENTER is confirmation of selection or changing and ESC is cancellation of selection
or changing. This menu is used to set up the relay element.
If user wants to set up the relay elements. Move curser to target with Up/Down key and
click ENTER key. And user can see the set up, changing point menu.
If user change the values, user can save that with F2 key. And it will display
confirming question.
If user wants to set the trip assign LED. Put the F4 key on that relay setting menu and
it will display as follows.

14
Lower menu Displayed contents
Voltage
It displays the values of three phase voltage.
If wiring is 3P3W, it can’t display phase
voltage.
Current/freq
It displays the values of current and frequency
of each phase.
M TYPE can display the load factor with %.
Phase It displays the values of all phases.
Power It displays the values of
ACTIVE,REACTIVE,REV-ACTIVE power.
Energy It displays the values of electric power
Power factor/DFR Power factor, displacement power factor
Harmonics/spectrum It displays the 2~13th harmonic distortions and
total harmonic distortion with diagram.
Vector diagram It displays three phase current, voltage with
vector diagram.
If user want to set the relay elements to assign LED, should move cursor to wanted
LED and put the left/right key. If you set the 27R relay elements to first trip assign
LED. You can see the display like above picture.
MEASURMENT
This menu has lower, detail menu like PROTECTIVE RELAY menu.
It displays measurement data on the 8 menu as follows.
1
11
1.
. .
. MMI
MMIMMI
MMI

15
Details are different by wiring type.
How to operate the key.
M
E
N
U
L
O
W
E
R
M
E
N
U
D
E
T
A
I
L
DISPLAY EXPLAN
HANDLING METHOD
The primary menu
of GIPAM.
This menu is the
top menu.
This menu displays
all available
mearsurments.
This menu displays
details of each
mearsurments .
Moving up/down :
Up, down directional
Key.
Moving to lower menu:
Select the menu user
wants and put the enter key.
Moving menu to menu:
Up, down directional key
Moving to top menu: cancel key
Moving to detail setting menu:
Select the menu user want and
put the enter key.
Moving to upper menu: cancel key
3P4W TYPE. 3P3W TYPE
1
11
1.
. .
. MMI
MMIMMI
MMI

16
INCIDENT HISTORY
User can observe the information of EVENT, FAULT, DEMAND and setting them in
this menu. GIPAM2000 can save total 800 events and 200 faults information. And the
device has demand information of W, VAR ,A. User can set up the time on the power
demand menu from 5 minutes to 60 minutes with 5 unit. And can set up the time on
the current demand menu from 10 seconds to 3600 seconds with 1 unit.
User can set up FAULT WAVE PERIOD (saved period) from 16 cycles to 512 cycles.
The device can save the before and after wave of the fault. If user set up the FAULT
WAVE PERIOD short, the number of saving will be increased. (max: 32)
① The child menu of INCIDENT HISTORY
Child menu1
Child menu2
Contents
It
displays all events info (year, month, day, hour, minute,
second, milli second)
It
displays all faults info(year, month, day, hour, minute,
second, milli second) and fault wave
It saves the value and time info of demand.
User can set up the demand setting.
User can set up the time on the power demand menu
from 5 minutes to 60 minutes with 5 unit. And can set up
the time on the current demand menu from 10 seconds
to 3600 seconds with 1 unit.
User can set up the period of fault wave.
U
ser can set up FAULT WAVE PERIOD (saved period)
from 16 cycles to 512 cycles.
1
11
1.
. .
. MMI
MMIMMI
MMI

17
② how to operate the key in the EVENT & FAULT menu
M
E
N
U
L
O
W
E
R
M
E
N
U
D
E
T
A
I
L
DISPLAY EXPLAN
HANDLING METHOD
The primary menu
of GIPAM.
This menu is the
top menu.
This menu displays
all available
saved data
-EVENT
-FAULT
-DEMAND
This menu displays
Details of saved data
It can display max 8 events
and 6 faults on the screen.
Moving up/down :
Up, down directional
Key.
Moving to lower menu:
Select the menu user
wants and put the enter key.
Moving menu to menu:
Up, down directional key
Moving to top menu: cancel key
Moving to detail setting menu:
Select the menu user want and
put the enter key.
Moving to upper menu: cancel key
Moving to next page: right, left key
(only EVENT, FAULT menu)
Observing FAULT wave:
Select the wave in list and click enter
key.
1
11
1.
. .
. MMI
MMIMMI
MMI

18
DEMAND menu
DISPLAY EXPLAN
HANDLING
M
E
N
U
L
O
W
E
R
M
E
N
U
1
L
O
W
E
R
M
E
N
U
2
D
E
T
A
I
L
The primary menu
of GIPAM.
This menu is the
top menu.
Moving up/down :
Up, down directional
Key.
Moving to lower menu:
Select the menu user
wants and put the enter key.
This menu displays
the information of DEMAND
Moving menu to menu:
Up, down directional key
Moving to top menu: cancel key
Moving to lower menu2 :
Select the DEMAND HISTORY and
put the enter key.
Moving menu to menu:
Up, down directional key
Moving to top menu: cancel key
Moving to detail setting menu:
Select the menu user want and
put the enter key.
This menu is available when
user selects DEMAND menu
on the lower menu1.
This menu displays the
the information of demand.
And user can set up the
mode on this menu.
Moving to upper menu: cancel key
Moving to next page: right, left key
(only EVENT, FAULT menu)
Observing FAULT wave:
Select the wave in list and click enter
key.
1
11
1.
. .
. MMI
MMIMMI
MMI

19
EVENT info display
GIPAM2000 displays info of EVENT & FAULTS as follows.
■ EVENT display
[EVENT No.] CODE: [EVENT type][event information]
TIME: [EVENT TIME TAG]
1. EVENT No. : the order of latest EVENT. The small number means that this is latest
EVENT.
2. EVENT type :
A: ALARM
R: RELAY operated.
S: STATUS
U: User managed.
3. EVENT information related with event type
3-1. The event related with RELAY elements
CODE: [R][PU/OP][ RELAY elements][I/T][H/L][REASON]
CODE: [R][PU/OP][ RELAY elements][I/T][H/L][REASON]CODE: [R][PU/OP][ RELAY elements][I/T][H/L][REASON]
CODE: [R][PU/OP][ RELAY elements][I/T][H/L][REASON]
PU/OP: PU – RELAY pick - up.
OP – The RELAY operated.
RELAY elements: the relay element come about (it displayed with ANSI
CODE)
I/T: I-instantaneous operation
T-time delay operation
H/L: H-HIGH SET, L-LOW SET
REASON: R,S,T- current and voltage
Vo, Io- zero phase current and voltage
V2, I2- negative seq. current and voltage
3-2. ALARM EVENT
CODE: [A][DETAIL]
CODE: [A][DETAIL]CODE: [A][DETAIL]
CODE: [A][DETAIL]
DETAIL: POWER FAIL- power failed
DIAG ERROE- system error
PRE ALARM- it means pre-alarm of all the relay elements.
NOT DEFINED- undefined operation was in the device
1
11
1.
. .
. MMI
MMIMMI
MMI

20
3-3. DI/DO EVENT
CODE: [S][DI/DO][ON/OFF][CHANGED DI/DO]
CODE: [S][DI/DO][ON/OFF][CHANGED DI/DO]CODE: [S][DI/DO][ON/OFF][CHANGED DI/DO]
CODE: [S][DI/DO][ON/OFF][CHANGED DI/DO]
DI/DO: reason of the event
ON/OFF: action
CHANGED DI/DO: The number of changed DI/DO
3-4. and so on
CODE: [The
CODE: [The CODE: [The
CODE: [The information
informationinformation
information]
]]
]
The information: it descriptions about the event directly.
■ FAULT display
[FAULT No.] CODE: [FAULT information related with FAULT type]
VALUE: [current, voltage value related with FAULT type]
TIME: [FAULT TIME TAG]
1. FAULT No. : the order of latest FAULT. The small number means that this is latest
FAULT.
2. FAULT information related with fault type
CODE: [
CODE: [CODE: [
CODE: [RELAY ELEME
RELAY ELEMERELAY ELEME
RELAY ELEMENT][INST/TIME][LOW/HIGH][R S T]
NT][INST/TIME][LOW/HIGH][R S T]NT][INST/TIME][LOW/HIGH][R S T]
NT][INST/TIME][LOW/HIGH][R S T]
RELAY elements: the relay element come about
(it displayed with ANSI CODE)
IST/TIME: IST-instantaneous operation
TIME-time delay operation
HIGH/LOW: HIGH-HIGH SET, LOW-LOW SET
R S T: The phase where the fault generated
3. The voltage, current value of FAULT related with fault type
VALUE: [The voltage, current value of FAULT related with fault type]
VALUE: [The voltage, current value of FAULT related with fault type] VALUE: [The voltage, current value of FAULT related with fault type]
VALUE: [The voltage, current value of FAULT related with fault type]
It displays the fault value.
1
11
1.
. .
. MMI
MMIMMI
MMI
Table of contents
Other LSIS Relay manuals
Popular Relay manuals by other brands

Reznor
Reznor CL31 Installation

ABB
ABB CIRCUIT SHIELD 49/50/51 instructions

Eaton
Eaton Cutler-Hammer Digitrip 3000 Instructions for installation, operation and maintenance

macromatic
macromatic Time Ranger TR-681 Series installation instructions

sisel
sisel ENDA EPDA1 quick start guide

System Sensor
System Sensor R-10T Installation and maintenance instructions