manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LST
  6. •
  7. Home Safety Product
  8. •
  9. LST HFM/153-27D User manual

LST HFM/153-27D User manual

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
Funk-HM_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
fi g. A
fi g. C
fi g. B
• Manual call points for different
applications
• High range of radio transmission
• 2 frequency bands (868MHz and
434MHz)
• Fault message when door is opened
• Case according to EN 54-11/B
• Communication with radio interface
FUIF511-27D
Description
The red Manual Call Point HFM/153-27D (fi g. A) and
the blue Manual Call Point HM/152-27D with lettering
„HAUSALARM“ (fi g. B) communicate with the RF Inter-
face FUIF511-27D via a secured radio protocol. The
plastic case, which is designed in accordance with
EN 54-11/B, is provided with an integrated antenna and
accommodates the 3.6V lithium battery.
4 data channels in the frequency band 868MHz as well
as 20 channels in the frequency band 434MHz are avai-
lable for the bidirectional data transmission. The avai-
lability of the channel is checked regularly. During the
learning phase of the detector, i.e., when the detector
is registered at the radio interface, a unique key, based
on a choice of several million codes, is created, which
allows the unambiguous identifi cation of the detector.
Regular status messages, monitoring of the battery vol-
tage and the long life of the included batteries ensure
the high reliability of the system.
A built-in LED optically indicates the activated condition
of the detector. The hinged door can be opened up to
an angle of 180° and it is provided with a replaceable
pane of glass. If the detector has been activated, an
integrated locking device prevents the closing of the
door. When the door is opened, the detector sends a
fault message to the radio interface.
Specifi cations
Operating voltage 3.6V (lithium battery, battery life approx. 1.5 years)
Ambient temperature 0°C to +60°C
Dimensions W × H × D 125 × 125 × 37 (mm)
Range of radio transmission (free air) 400m
Frequency band 868MHz or 434MHz
Manual Radio Call Points
HFM/153-27D, HM/152-27D
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
Funk-HM_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
Manual call point red
Colour fl ame red, RAL 3000
Approval VdS G204014
Order number 245020
Order name Manual Call Point/Red/RF HFM/153-27D
Manual call point blue „HAUSALARM“
Colour blue
Approval VdS G105508
Order number 245021
Order name Manual Call Point/Blue/RF HM/152-27D
Lithium battery
Order number 310021
Order name Lithium Battery 3.6V/2.2Ah

This manual suits for next models

1

Other LST Home Safety Product manuals

LST IBSST-DR-P01 User manual

LST

LST IBSST-DR-P01 User manual

LST M510E-4-20 User manual

LST

LST M510E-4-20 User manual

LST M210E User manual

LST

LST M210E User manual

LST M503ME User manual

LST

LST M503ME User manual

LST M220E User manual

LST

LST M220E User manual

LST MGE8-1 User manual

LST

LST MGE8-1 User manual

LST IBSOU-DD-P01 User manual

LST

LST IBSOU-DD-P01 User manual

LST M400DKMB-AS User manual

LST

LST M400DKMB-AS User manual

LST M221E User manual

LST

LST M221E User manual

LST HFM/3/22/02 User manual

LST

LST HFM/3/22/02 User manual

LST M201E-240-DIN User manual

LST

LST M201E-240-DIN User manual

Popular Home Safety Product manuals by other brands

Heath Zenith Motion Sensor Entryway Light SL-5610/15 owner's manual

Heath Zenith

Heath Zenith Motion Sensor Entryway Light SL-5610/15 owner's manual

Heath Zenith DualBrite Motion Sensor Light Control 2LBL3 Operating instructions and parts manual

Heath Zenith

Heath Zenith DualBrite Motion Sensor Light Control 2LBL3 Operating instructions and parts manual

D-Link mydlink DCH-S220 quick start guide

D-Link

D-Link mydlink DCH-S220 quick start guide

First Alert Fire Escape Ladder EL52W-2 user manual

First Alert

First Alert Fire Escape Ladder EL52W-2 user manual

PNI SAFE HOUSE PG940 user manual

PNI

PNI SAFE HOUSE PG940 user manual

Summer 07030A instruction manual

Summer

Summer 07030A instruction manual

IMS IB462He Specification sheet

IMS

IMS IB462He Specification sheet

First Alert EL50 user manual

First Alert

First Alert EL50 user manual

Regalo Safety Gate Assembly and installation instructions

Regalo

Regalo Safety Gate Assembly and installation instructions

GE 57884 installation guide

GE

GE 57884 installation guide

Cooper Lighting Sure-Lites HS1R instruction manual

Cooper Lighting

Cooper Lighting Sure-Lites HS1R instruction manual

Sensaphone 1104 Addendum

Sensaphone

Sensaphone 1104 Addendum

AJAX Systems HomeSiren quick start guide

AJAX Systems

AJAX Systems HomeSiren quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.