manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LST
  6. •
  7. Security Sensor
  8. •
  9. LST UVIR2 16591 User manual

LST UVIR2 16591 User manual

Other LST Security Sensor manuals

LST Orbis 246042 User manual

LST

LST Orbis 246042 User manual

LST B401RM User manual

LST

LST B401RM User manual

LST B524IEFT-1 User manual

LST

LST B524IEFT-1 User manual

LST FI750/RF/OT User manual

LST

LST FI750/RF/OT User manual

LST Series 65/XP95 User manual

LST

LST Series 65/XP95 User manual

LST Series 200 User manual

LST

LST Series 200 User manual

LST OH-13001 User manual

LST

LST OH-13001 User manual

LST B312NL User manual

LST

LST B312NL User manual

LST 16589 User manual

LST

LST 16589 User manual

LST 2351TEM User manual

LST

LST 2351TEM User manual

LST FI750/RF/OT User manual

LST

LST FI750/RF/OT User manual

LST ASA-45681-210 User manual

LST

LST ASA-45681-210 User manual

LST AISA-45681-321 User manual

LST

LST AISA-45681-321 User manual

LST 246100 User manual

LST

LST 246100 User manual

LST FTX-P1 User manual

LST

LST FTX-P1 User manual

LST AW-55000-420 User manual

LST

LST AW-55000-420 User manual

LST FI750/RF/O Operator's manual

LST

LST FI750/RF/O Operator's manual

LST 200 Series User manual

LST

LST 200 Series User manual

LST 5451EIS User manual

LST

LST 5451EIS User manual

LST 2251CTLE User manual

LST

LST 2251CTLE User manual

LST ASR-45681-242 User manual

LST

LST ASR-45681-242 User manual

LST ECO1000 User manual

LST

LST ECO1000 User manual

LST 4351E User manual

LST

LST 4351E User manual

LST 5351E User manual

LST

LST 5351E User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
UVIR2-16591_DBL_LST_EN_0850.PDF • PAGE 1
ABuilding Safety. Building Security.
Flame Detector UVIR
2
16591
Description
• UV sensor combined with dual IR
sensor, according to EN 54-10,
Class 1
• Detection of open fl ames through
fl ickering IR and UV radiation
• Highest immunity to deceptive alarms
• Selectable response delay
• Relay contacts for alarm and fault
• Integrated optical test function
The Flame Detector 16591 responds to the fl ickering
infrared and ultraviolet radiation of open fl ames. There-
fore, it is extremely well suitable for the detection of
fi res which are diffi cult to detect with common smoke
detectors – for example, alcoholic fi res or gas fl ames.
The detector is ideal for the following applications:
• Aircraft hangars
• Power stations and turbine plants
• Military bases
• Nuclear facilities
• Fuel depots
Thanks to the combination of two independent infrared
sensors for different wavelengths and an UV sensor as
well as an intelligent evaluation logic, the detector can
distinguish particularly safely between alarm situations
and deceptive alarms. Therefore, it is very insensitive
to disturbance sources such as sunlight, fl uorescent
lamps or electric arcs.
The detector complies with EN 54-10, Class 1, which
means it is suitable to detect fl ames up to a distance
of 25m.
The response delay of the detector can be selected in
4 steps between 1 and 8s. An alarm and a fault conditi-
on is signalled via two dry relay contacts. Conventional
technology is used for alarm transmission to the fi re
detection control panel. The detector can be integra-
ted into an ADM loop by means of a conventional zone
module.
A simple test of the detector can be carried out by
means of the integrated optical self test function, which
does not require additional tools. During this self test,
built-in infrared and ultraviolet light sources simulate a
fi re situation which activates the detector.
The detector has been designed for indoor and outdoor
use. The optional Detector Mounting Bracket 7127 al-
lows stepless horizontal and vertical adjustment for the
easy adaptation of the detector to the required monito-
ring area.
For use in explosion-hazardous areas, an Ex version of
the fl ame detector is available on request.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
UVIR2-16591_DBL_LST_EN_0850.PDF • PAGE 2
ABuilding Safety. Building Security.
Operating voltage 14 – 30VDC
Current consumption at 24VDC max. 8mA (quiescent), 14mA (alarm)
Monitored angle 90°
Range max. 25m
Spectral sensitivity 1 – 2.7µm (infrared)
185 – 260nm (UV)
Contact rating of relay outputs max. 1A at 50VDC
Ambient temperature -10°C to +55°C
Dimensions W × H × D 108 × 142 × 82 (mm)
Colour sky blue, RAL 5015
Weight 2kg
Protection class IP65
Order number 243012
Order name Flame Detector/UVIR2 16591
Detector Mounting Bracket
Material stainless steel
Adjustment range vertical 0 to -45°
Adjustment range horizontal ±45°
Dimensions W × H × D 82 × 98 × 90 (mm)
Weight 650g
Order number 249141
Order name Detector Mounting Bracket/Flame Detector 7127
Specifi cations