manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LST
  6. •
  7. Smoke Alarm
  8. •
  9. LST AI-58000-500 User manual

LST AI-58000-500 User manual

Other LST Smoke Alarm manuals

LST BEAMLRK User manual

LST

LST BEAMLRK User manual

LST ECO1002 User manual

LST

LST ECO1002 User manual

LST MCP5A Series User manual

LST

LST MCP5A Series User manual

LST 1151EIS User manual

LST

LST 1151EIS User manual

LST AO-58000-600 User manual

LST

LST AO-58000-600 User manual

LST HT-11005 User manual

LST

LST HT-11005 User manual

LST HT-11003 User manual

LST

LST HT-11003 User manual

LST HT-11006 User manual

LST

LST HT-11006 User manual

LST HT-11001 User manual

LST

LST HT-11001 User manual

LST 249020 User manual

LST

LST 249020 User manual

LST WMSTR-WR-P01 User manual

LST

LST WMSTR-WR-P01 User manual

LST GD-55000-132 User manual

LST

LST GD-55000-132 User manual

LST SG70-1 User manual

LST

LST SG70-1 User manual

LST ÜMM-55000-833 User manual

LST

LST ÜMM-55000-833 User manual

LST FC600/O User manual

LST

LST FC600/O User manual

LST GO-55000-317 User manual

LST

LST GO-55000-317 User manual

LST ECO1005 User manual

LST

LST ECO1005 User manual

LST FC600/TDIFF/57 User manual

LST

LST FC600/TDIFF/57 User manual

LST OP-12001 User manual

LST

LST OP-12001 User manual

LST AO-55000-620 User manual

LST

LST AO-55000-620 User manual

LST HT-11004 User manual

LST

LST HT-11004 User manual

LST FC600/TMAX/78 User manual

LST

LST FC600/TMAX/78 User manual

LST ECO1003 User manual

LST

LST ECO1003 User manual

LST AOEX-55000-640 User manual

LST

LST AOEX-55000-640 User manual

Popular Smoke Alarm manuals by other brands

Dyna-Glo DGY784BDP installation instructions

Dyna-Glo

Dyna-Glo DGY784BDP installation instructions

NOXE LUMENS Installation and user guide

NOXE

NOXE LUMENS Installation and user guide

Develco SMAZB-141 installation manual

Develco

Develco SMAZB-141 installation manual

Kidde PI2010CA user guide

Kidde

Kidde PI2010CA user guide

Honeywell 5800COMBO Installation and setup guide

Honeywell

Honeywell 5800COMBO Installation and setup guide

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

First Alert PC900V user manual

First Alert

First Alert PC900V user manual

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
AI-58000-500_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
Ionisation Smoke Detector
AI-58000-500
Description
The Ionisation Smoke Detector AI-58000-500 was de-
veloped for the safe detection of a wide range of smoke
aerosols. The modern design of the ionisation chamber
allows to reliably evaluate the characteristics of fi re.
The dual chamber principle with measurement and refe-
rence chamber ensures the automatic compensation of
environmental impact.
The response sensitivity of the detector can be adjus-
ted in 5 steps, via the fi re detection control panel.
The proven ADM loop technology with Apollo/Discovery
protocol establishes a permanent communication be-
tween the fi re detection control panel and the detector.
That ensures a periodical function testing of the detec-
tor. In the control panel all types of fi res are detected by
continuously comparing fi re patterns.
The infl uence of contamination of the measurement
system is compensated for by using intelligent evalu-
ation algorithms. With that, the response sensitivity of
the detector is kept constant for a long time – a further
effective step to avoid false alarms.
The two LEDs with 360° visibility indicate the activated
condition of the detector. The detector address is se-
lected by means of a code card in the detector base.
Therefore the detector can be changed without additi-
onal tools.
The detector can be attached to various bases and it
can be protected against theft.
• ADM loop technology with
Apollo/Discovery protocol
• Sensitivity selectable in 5 steps
• Optional connection of remote
indicator
• Constant response sensitivity
• Sealed electronics
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
AI-58000-500_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
Specifi cations
Operating voltage Supply through loop voltage
Current consumption typ. 500µA (quiescent)
Ambient temperature -20°C to +60°C (no condensation or icing)
Relative humidity 0 – 95% (no condensation)
Radioactive compound Am241, 0.9µCi (33.3kBq)
Dimensions ø × H 100 × 42 (mm)
Colour white
Weight 105g
Approvals VdS G200073
Order number 240026
Order name Ionisation Smoke Detector/Anal./Disc/Apo AI-58000-500