manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LST
  6. •
  7. Smoke Alarm
  8. •
  9. LST AI-58000-500 User manual

LST AI-58000-500 User manual

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
AI-58000-500_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
Ionisation Smoke Detector
AI-58000-500
Description
The Ionisation Smoke Detector AI-58000-500 was de-
veloped for the safe detection of a wide range of smoke
aerosols. The modern design of the ionisation chamber
allows to reliably evaluate the characteristics of fi re.
The dual chamber principle with measurement and refe-
rence chamber ensures the automatic compensation of
environmental impact.
The response sensitivity of the detector can be adjus-
ted in 5 steps, via the fi re detection control panel.
The proven ADM loop technology with Apollo/Discovery
protocol establishes a permanent communication be-
tween the fi re detection control panel and the detector.
That ensures a periodical function testing of the detec-
tor. In the control panel all types of fi res are detected by
continuously comparing fi re patterns.
The infl uence of contamination of the measurement
system is compensated for by using intelligent evalu-
ation algorithms. With that, the response sensitivity of
the detector is kept constant for a long time – a further
effective step to avoid false alarms.
The two LEDs with 360° visibility indicate the activated
condition of the detector. The detector address is se-
lected by means of a code card in the detector base.
Therefore the detector can be changed without additi-
onal tools.
The detector can be attached to various bases and it
can be protected against theft.
• ADM loop technology with
Apollo/Discovery protocol
• Sensitivity selectable in 5 steps
• Optional connection of remote
indicator
• Constant response sensitivity
• Sealed electronics
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
AI-58000-500_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
Specifi cations
Operating voltage Supply through loop voltage
Current consumption typ. 500µA (quiescent)
Ambient temperature -20°C to +60°C (no condensation or icing)
Relative humidity 0 – 95% (no condensation)
Radioactive compound Am241, 0.9µCi (33.3kBq)
Dimensions ø × H 100 × 42 (mm)
Colour white
Weight 105g
Approvals VdS G200073
Order number 240026
Order name Ionisation Smoke Detector/Anal./Disc/Apo AI-58000-500

Other LST Smoke Alarm manuals

LST FC600/TMAX/78 User manual

LST

LST FC600/TMAX/78 User manual

LST ND2251EM User manual

LST

LST ND2251EM User manual

LST SLR-E-IS User manual

LST

LST SLR-E-IS User manual

LST 7251 User manual

LST

LST 7251 User manual

LST ECO1002 User manual

LST

LST ECO1002 User manual

LST 6500R User manual

LST

LST 6500R User manual

LST ECO1003 User manual

LST

LST ECO1003 User manual

LST HT-11003 User manual

LST

LST HT-11003 User manual

LST HT-11004 User manual

LST

LST HT-11004 User manual

LST AOEX-55000-640 User manual

LST

LST AOEX-55000-640 User manual

LST HT-11002 User manual

LST

LST HT-11002 User manual

LST GD-55000-127 User manual

LST

LST GD-55000-127 User manual

LST BEAMLRK User manual

LST

LST BEAMLRK User manual

LST FC600 Series User manual

LST

LST FC600 Series User manual

LST ECO1004T User manual

LST

LST ECO1004T User manual

LST FI750/RF/O User manual

LST

LST FI750/RF/O User manual

LST ÜMS-55000-841 User manual

LST

LST ÜMS-55000-841 User manual

LST AO-58000-600 User manual

LST

LST AO-58000-600 User manual

LST ECO1005T User manual

LST

LST ECO1005T User manual

LST 6500 User manual

LST

LST 6500 User manual

LST OP-12001 User manual

LST

LST OP-12001 User manual

LST HT-11006 User manual

LST

LST HT-11006 User manual

LST 249020 User manual

LST

LST 249020 User manual

LST GI-55000-217 User manual

LST

LST GI-55000-217 User manual

Popular Smoke Alarm manuals by other brands

Gamewell BD-SS quick guide

Gamewell

Gamewell BD-SS quick guide

Kidde i12010SCO user manual

Kidde

Kidde i12010SCO user manual

Universal SS-770 instructions

Universal

Universal SS-770 instructions

Fike 63-1052 Installation and maintenance instructions

Fike

Fike 63-1052 Installation and maintenance instructions

MIIDEX LIGHTING MV3 instructions

MIIDEX LIGHTING

MIIDEX LIGHTING MV3 instructions

ADEMCO PY2700TEM Installation and maintenance instructions

ADEMCO

ADEMCO PY2700TEM Installation and maintenance instructions

Aico Ei100R manual

Aico

Aico Ei100R manual

FireAngel THERMOPTEK ST-623E manual

FireAngel

FireAngel THERMOPTEK ST-623E manual

ARMA NV866H-LSW quick start guide

ARMA

ARMA NV866H-LSW quick start guide

Firex TPCI user manual

Firex

Firex TPCI user manual

EI Ei105R3 Instruction leaflet

EI

EI Ei105R3 Instruction leaflet

Paradox Digiplex EVO192 installation guide

Paradox

Paradox Digiplex EVO192 installation guide

BRK electronic SA520B quick start guide

BRK electronic

BRK electronic SA520B quick start guide

Fire-Lite CP355 Installation and maintenance instructions

Fire-Lite

Fire-Lite CP355 Installation and maintenance instructions

Fire-Lite Keltron 95M3158 TTM-RPS Wiring diagram

Fire-Lite

Fire-Lite Keltron 95M3158 TTM-RPS Wiring diagram

Electronics Ei 605C Installation

Electronics

Electronics Ei 605C Installation

Abus HSRM20000 / RM40 Li user manual

Abus

Abus HSRM20000 / RM40 Li user manual

Sensing TEK SDZ2100 WSN Smoke instruction manual

Sensing TEK

Sensing TEK SDZ2100 WSN Smoke instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.