manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lumascape
  6. •
  7. Lantern
  8. •
  9. Lumascape LS482 Guide

Lumascape LS482 Guide

Other Lumascape Lantern manuals

Lumascape LS345 User manual

Lumascape

Lumascape LS345 User manual

Lumascape LS333ANS-2 User manual

Lumascape

Lumascape LS333ANS-2 User manual

Lumascape LS9160 User manual

Lumascape

Lumascape LS9160 User manual

Lumascape Linealux L3 LS9031 User manual

Lumascape

Lumascape Linealux L3 LS9031 User manual

Lumascape LS9120 User manual

Lumascape

Lumascape LS9120 User manual

Popular Lantern manuals by other brands

DS Produkte TRF18P0752-1 instructions

DS Produkte

DS Produkte TRF18P0752-1 instructions

Stahl ECOLUX 6610 Series operating instructions

Stahl

Stahl ECOLUX 6610 Series operating instructions

SNOWJOE SUNJOE 24V-LGT500-CT Operator's manual

SNOWJOE

SNOWJOE SUNJOE 24V-LGT500-CT Operator's manual

PRG VARI LITE VL5 Service manual

PRG

PRG VARI LITE VL5 Service manual

Raytec VARIO2 series installation guide

Raytec

Raytec VARIO2 series installation guide

ENSA LEDBT18WS2 installation instructions

ENSA

ENSA LEDBT18WS2 installation instructions

LUG OFFICE LB LED N/T Installation instruction

LUG

LUG OFFICE LB LED N/T Installation instruction

Draper RLEDL19/B instructions

Draper

Draper RLEDL19/B instructions

Green Lighting TRI-SENSOR GL4612LU Assembly & fitting instructions

Green Lighting

Green Lighting TRI-SENSOR GL4612LU Assembly & fitting instructions

Panasonic EY3741B57 operating instructions

Panasonic

Panasonic EY3741B57 operating instructions

Clas Ohlson LCC8T instruction manual

Clas Ohlson

Clas Ohlson LCC8T instruction manual

Coolon WDN-140 manual

Coolon

Coolon WDN-140 manual

shada 1000436 instruction manual

shada

shada 1000436 instruction manual

BEGA 84 036 Instructions for use

BEGA

BEGA 84 036 Instructions for use

BEGA 33 596 Instructions for use

BEGA

BEGA 33 596 Instructions for use

Dale Tiffany GT701162 Assembly instructions

Dale Tiffany

Dale Tiffany GT701162 Assembly instructions

Wagan Brite Nite Pop-Up USB Lantern user manual

Wagan

Wagan Brite Nite Pop-Up USB Lantern user manual

Eaton Crouse-Hinds Pauluhn DLLA M2 Series Installation & maintenance information

Eaton

Eaton Crouse-Hinds Pauluhn DLLA M2 Series Installation & maintenance information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IMPORTANT INSTRUCTIONS
C1317US - 2006_07_REV001
For Installation LS482
MODELS LS482
Mains Voltage depicted 12V version available
Check fixture for wattage. A.C.N. 010 572 773
Relamping4
1
2 3
Note: To achieve IP66 rating, use round cable (size 5-10mm) to suit entry gland supplied with fixture.
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19
San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
INC.
Mounting fasteners
not supplied by
Lumascape
Surface Mount Plate
300mm (11.8in)
Direct Burial Post
Mounting fasteners
not supplied by
Lumascape
Discreet Mount
Outside Diameter
Ø150mm
Remove lid from fixture
and pull out gear tray.
Pull cable through gland
and tighten.
Connect leads to
terminal block.
Slide gear tray back into
mounting pole.
Wire up fixture
Check wattage and
insert lamp into fixture.
Test to ensure lamp and
fixture is operational.
Insert lamp into fixture
Put lid on fixture
and seal by
tightening all
three screws
around the base.
Fit cover & seal
1
2
Open fixture as shown in .
Remove old lamp from fixture as shown below.
step 2
3
4
Insert lamp into fixture as shown in .
Seal fixture as shown in .
step 4
step 5
PCD Ø120mm
Hole Size Ø11mm
Warning
Rubber seal protects gear tray from moisture.
Do not use force. Make sure seal fits tightly against pole.
INC.
Lumascape USA Inc.
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
T 1-(650)-595-LUMA(5862)
F 1-(650)-595-5820
E [email protected]
W www.lumascape.com
Free Call US & Canada1-866-695-LUMA(5862)
Lumascape USA Inc. 2006©
www.lumascape.com
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
LUMASCAPE USA INC
Free Call 1-866-695-LUMA(5862)
C1778US 09_2006
Warning: The Luminaire should only be used complete with its protective shield (cover)
IMPORTANT INSTRUCTIONS
For Installation LS482 Halogen Bi-Pin
1
Mounting fasteners
not supplied by
Lumascape
Surface Mount Plate
300mm (11.8in)
Direct Burial Post
Mounting fasteners
not supplied by
Lumascape
Discreet Mount
Outside
33
INTEGRAL MODEL
WIRING ONLY:
Remove gear tray
from post.
Pull cable through
gland and tighten.
Connect leads to
terminal block.
Ensure that the earth
terminal is fitted to the
inside of the post.
Slide gear tray back
into the post.
REMOTE MODEL
WIRING ONLY:
Remove gear tray
from post.
Pull cable through
gland and tighten.
Connect leads to
terminal block.
Slide gear tray back
into the post.
5Fit the head
onto the post
and seal by
tightening all
three screws.
4
Important Notes:
Rubber seal protects
gear tray from moisture.
Do not use force.
Make sure seal fits
tightly against post.
Important Notes:
Rubber seal protects
gear tray from moisture.
Do not use force.
Make sure seal fits
tightly against post.
2Remove the head
from the post by
unscrewing the
three screws.
OR
Relamping
1
2
Remove head as shown in .
Remove old lamp from fixture as shown.
step 2
3
4
Insert lamp into fixture as shown in
Seal fixture as shown in .
step 4.
step 5
Check the lamp wattage and insert
the lamp into the lampholder.
Test to ensure that the lamp and
fixture is operational.
MODELS LS482-293XXXQX BI-PIN INTEGRAL
12V 50watt Halogen Bi-pin Max.
LS482-293XXXRX BI-PIN REMOTE
12V 50watt Halogen Bi-pin Max.
IP66 rated
PCD Ø4.7” (120mm)
Hole Size Ø0.4” (11mm)
.CNI
Lumascape USA Inc.
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
T 1-(650)-595-LUMA(5862)
F 1-(650)-595-5820
E [email protected]
W www.lumascape.com
Free Call US & Canada1-866-695-LUMA(5862)
Lumascape USA Inc. 2006©
www.lumascape.com
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
LUMASCAPE USA INC
Free Call 1-866-695-LUMA(5862)
C1779US 30_2010
Warning: The Luminaire should only be used complete with its protective shield (cover)
IMPORTANT INSTRUCTIONS
Wiring Connections
For Installation LS482 E26 / E27
MODELS LS482-291XXXRX E26 / E27
120V 60watt Incandscent Max.
120V 23watt Self-ballasted CFL Max.
IP66 rated
1
Mounting fasteners
Supply
not supplied by
Lumascape
Surface Mount Plate
Mounting fasteners
not supplied by
Lumascape
Discreet Mount
Relamping
1
2
Remove head as shown in .
Remove old lamp from fixture as shown.
step 2
3
4
Insert lamp into fixture as shown in
Seal fixture as shown in .
step 6.
step 7
7Fit the head onto the
post and seal by
Re-attach earth spade connector.
tightening all three
screws.
6
3 4
2
Check the lamp wattage and insert
Pull out gear tray and make connections
to supply cable.
the lamp into the lampholder.
Test to ensure that the lamp and
fixture is operational.
Remove the head
from the post by
unscrewing the
three screws.
5Re-install the gear tray. Ensure bracket
is fitted into groove.
Outside
PCD Ø4.7” (120mm)