Lumascape LS345 User manual

10-15 MIN.
60
30
45
GIMBAL
LOCKING
SCREW
GIMBAL
ROTATION
LOCKING
SCREW
A
START
HERE
IMPORTANT INSTRUCTIONS
FOR UNDERWATER USE
t90 Ct90 C 1m A.C.N. 010 572 773
1 32
7 8
4 65
Lumascape Lighting Industries 2006©
www.lumascape.com.au
LUMASCAPE
HEAD OFFICE
T 07 3286 2299 F 07 3286 6599
LUMASCAPE
SYDNEY - NSW
T 02 9519 6860 F 02 9519 8834
LUMASCAPE
MELBOURNE - VIC
T 03 9686 1900 F 03 9686 1700
ECC LIGHTING
LUMASCAPE AGENT - NZ
T 09 379 9680 F 09 308 9328
H.I. LIGHTING
LUMASCAPE AGENT - WA
T 08 9321 5422 F 08 9321 5881
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
T 07 4031 4490 F 07 4031 5933
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
LUMASCAPE USA INC
Free Call 1-866-695-LUMA(5862)
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SA
T 08 8232 0074 F 08 8232 0076
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
W www.lumascape.com.au
WARNING
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IF
CABLE ASSEMBLY IS TAMPERED WITH.
If cable damaged replace with cable supplied by LUMASCAPE only.
90o
Locate Fixtures
Site fixture in proximity to cabling.
Use discretion in locating fixtures as
glass can become very hot and may
burn.
100MM
(3.93IN)
100-250MM
(3.93-9.84IN)
160MM
(6.3IN)
Mount Bracket to Fixture
Mount bracket supplied to fixture using
the M10 dome nuts and washers as
shown
DOME NUT
SPRING
WASHER
FLAT
WASHER
BRACKET
Mount Fixture
Mount fixture to secure surface.
Orientate fixture as required and
tighten nuts
30o
90o
BRACKET TOP VIEW
70MM (2.75IN)
2 X 8MM
12MM
30o
90o
Insert Lamp
Check lamp WATTAGE, VOLTAGE, and
TYPE, and insert into lampholder (refer to
lamp manufacturers documentation for
handling precautions).
Adjust Gimbal Position.
Adjust the vertical position of the gimbal to
minimise glare, and tighten locking screw.
Rotate gimbal to desired direction and
tighten locking screw.
Test Fixture
Test to ensure fixture is operational. Allow to
burn for 10-15 minutes to allow any
moisture in fixture to evaporate. C1612US - 2006_07_REV001
Further
information
over page
C1613 - 2007_01_REV-003
Connect Supply
Connect fixture to supply cable according to
local wiring rules.
For Installation LS345: MH, UNDERWATER
1
2
6
5
3
4
Torque Pattern
Seal Fixture
Ensure seal and sealing surface is clean.
Clean glass if necessary. Tighten lid screws
using the 3mm Allen key supplied.
Lumascape recommends tightening in the
above Torque Pattern to 2.5 - 3 N.m.
DO NOT OVER TIGHTEN.
Warning: The Luminaire should only be used complete with its protective shield (cover)
To avoid potential unsafe lamp failure, the luminaire should be switched off at least once a week
DISCONTINUED PRODUCT

GUIDE
PINS
GEAR
ASSEMBLY
6
6
78
B
Warning: The Luminaire should only be used complete with its protective shield (cover)
IMPORTANT INSTRUCTIONS
t90 Ct90 C 1m A.C.N. 010 572 773
A CB
4 5
1 32
C1613 - 2007_01_REV-003
Lumascape Lighting Industries 2006©
LUMASCAPE
HEAD OFFICE
T 07 3286 2299 F 07 3286 6599
LUMASCAPE
SYDNEY - NSW
T 02 9519 6860 F 02 9519 8834
LUMASCAPE
MELBOURNE - VIC
T 03 9686 1900 F 03 9686 1700
ECC LIGHTING
LUMASCAPE AGENT - NZ
T 09 379 9680 F 09 308 9328
H.I. LIGHTING
LUMASCAPE AGENT - WA
T 08 9321 5422 F 08 9321 5881
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
T 07 4031 4490 F 07 4031 5933
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SA
T 08 8232 0074 F 08 8232 0076
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
W www.lumascape.com.au
90o
RELAMPING
LAMP SOURCE CONVERSION INSTRUCTION
6
Isolate and Open Fixture
Ensure the fixture is electrically isolated.
Loosen the screws with the Allen Key
provided. If necessary gently lever lid out
with a large screwdriver.
Replace Lamp
Remove old lamp and check condition of
lampholder. Check new lamp WATTAGE,
VOLTAGE and TYPE. Insert new
lamp,(Refer installation instruction 4 over.)
Adjust, Aim, Test and Seal
68
If necessary, readjust and re-aim gimbal
position.
Test and seal fixture as per installation
Instructions through to , over.
GIMBAL
LOCKING
SCREW
6
6
78
Isolate and
Open Fixture
Ensure the fixture is electrically isolated.
Loosen the screws with the Allen Key
provided. If necessary gently lever lid out
with a large screwdriver.
Remove Gimbal
Remove gimbal by loosening the locking
screw and pulling vertically.
Remove Gear Assembly
Remove gear assembly by pulling vertically
(Note: Gear assembly may be screwed to
fixture body).
Insert New Gear Assembly
Align holes in gear tray with Threaded
Guide Pins in base of fixture and insert
fully, fit S/S nuts to retain
Replace Lamp
Remove old lamp and check condition of
lampholder. Check new lamp WATTAGE,
VOLTAGE and TYPE. Insert new
lamp,(Refer installation instruction 4 over.)
Adjust, Aim, Test and Seal
68
If necessary, readjust and re-aim gimbal
position.
Test and seal fixture as per installation
instructions through to , over.
IMPORTANT INSTRUCTIONS
FOR UNDERWATER USE
www.lumascape.com.au
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
LUMASCAPE USA INC
Free Call 1-866-695-LUMA(5862)
For Installation LS345 UNDERWATER
To avoid potential unsafe lamp failure, the luminaire should be switched off at least once a week
DISCONTINUED PRODUCT

www.lumascape.com.au
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
Tel (07) 3286 2299 Fax (07) 3286 6599 Email [email protected]
LUMASCAPE
HEAD OFFICE - QLD
Tel (07) 3286 2299
Fax (07) 3286 6599
LUMASCAPE
SYDNEY - NSW
Tel (02) 9519 6860
Fax (02) 9519 8834
LUMASCAPE
MELBOURNE - VIC
Tel (03) 9686 1900
Fax (03) 9686 1700
LUMASCAPE USA INC.
SAN FRANCISCO - CA
Tel 1-(650)-595-5862
Fax 1-(650) 595-5820
H.I. LIGHTING
LUMASCAPE AGENT - WA
Tel (08) 9321 5422
Fax (08) 9321 5881
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SA
Tel (08) 8232 0074
Fax (08) 8232 0076
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
Tel (07) 4031 4490
Fax (07) 4031 5933
ECC LIGHTING
LUMASCAPE AGENT - NZ
Tel (09) 379 9680
Fax (09) 308 9328
Copyright ©2006 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773www.lumascape.com.au
IMPORTANT INFORMATION
WARNING - To reduce the risk of FIRE or INJURY:
Luminaires and transformers to be installed by qualified installers only.
Luminaires to be used for intended purpose only. e.g Wall Mount fittings must be wall mounted.
Luminaires can become very hot. Use discretion in placement.
Do not touch hot lens, guard, or enclosure.
CAUTION - HOT SURFACE. Keep away from curtains and other combustible material.
Turn Off/Unplug and allow to cool before replacing lamp.
Keep lamp away from materials that may burn.
Never touch lamp with bare fingers. Oil from skin may damage lamp. Hold lamp with soft cloth when installing or replacing.
Do not operate the luminaires with a missing or damaged parts.
Replace any cracked protective shield
Use only lamp type, voltage and wattage as specified by Lumascape on the product label.
Use only genuine Lumascape parts to replace damaged or missing components.
Luminaires supplied with Loctite Silver Grade Anti Seize lubricant on threads. Reapply if needed.
Refer to instructions for installation and operating requirements.
Ensure installation complies with local regulations
SAVE THESE INSTRUCTIONS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
IMPORTANT SAFETY INSTRUCTIONS
C1721 - 2006_11_REV-002
A
232 0074
08) 8232 0076
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
GHTIN
LUMASCAPE AGENT - NZ
Tel (09) 379 9680
C
ax (09) 308 9328
right ©2006 Lumascape Lighting Industries Pty. Ltd. ABN
DISCONTINUED PRODUCT
Other Lumascape Lantern manuals