manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lumascape
  6. •
  7. Lantern
  8. •
  9. Lumascape LS333ANS-2 User manual

Lumascape LS333ANS-2 User manual

Other Lumascape Lantern manuals

Lumascape LS9160 User manual

Lumascape

Lumascape LS9160 User manual

Lumascape LS482 Guide

Lumascape

Lumascape LS482 Guide

Lumascape Linealux L3 LS9031 User manual

Lumascape

Lumascape Linealux L3 LS9031 User manual

Lumascape LS345 User manual

Lumascape

Lumascape LS345 User manual

Lumascape LS9120 User manual

Lumascape

Lumascape LS9120 User manual

Popular Lantern manuals by other brands

DS Produkte TRF18P0752-1 instructions

DS Produkte

DS Produkte TRF18P0752-1 instructions

Stahl ECOLUX 6610 Series operating instructions

Stahl

Stahl ECOLUX 6610 Series operating instructions

SNOWJOE SUNJOE 24V-LGT500-CT Operator's manual

SNOWJOE

SNOWJOE SUNJOE 24V-LGT500-CT Operator's manual

PRG VARI LITE VL5 Service manual

PRG

PRG VARI LITE VL5 Service manual

Raytec VARIO2 series installation guide

Raytec

Raytec VARIO2 series installation guide

ENSA LEDBT18WS2 installation instructions

ENSA

ENSA LEDBT18WS2 installation instructions

LUG OFFICE LB LED N/T Installation instruction

LUG

LUG OFFICE LB LED N/T Installation instruction

Draper RLEDL19/B instructions

Draper

Draper RLEDL19/B instructions

Green Lighting TRI-SENSOR GL4612LU Assembly & fitting instructions

Green Lighting

Green Lighting TRI-SENSOR GL4612LU Assembly & fitting instructions

Panasonic EY3741B57 operating instructions

Panasonic

Panasonic EY3741B57 operating instructions

Clas Ohlson LCC8T instruction manual

Clas Ohlson

Clas Ohlson LCC8T instruction manual

Coolon WDN-140 manual

Coolon

Coolon WDN-140 manual

shada 1000436 instruction manual

shada

shada 1000436 instruction manual

BEGA 84 036 Instructions for use

BEGA

BEGA 84 036 Instructions for use

BEGA 33 596 Instructions for use

BEGA

BEGA 33 596 Instructions for use

Dale Tiffany GT701162 Assembly instructions

Dale Tiffany

Dale Tiffany GT701162 Assembly instructions

Wagan Brite Nite Pop-Up USB Lantern user manual

Wagan

Wagan Brite Nite Pop-Up USB Lantern user manual

Eaton Crouse-Hinds Pauluhn DLLA M2 Series Installation & maintenance information

Eaton

Eaton Crouse-Hinds Pauluhn DLLA M2 Series Installation & maintenance information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Warranty void if not installed as per installation instructions
INSTALLATION INSTRUCTIONS
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
E [email protected]
W www.lumascape.com.au
IN0040 - 23 October 2013
Copyright ©2013 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
LS333ANS-2: Underwater Luminaire
A.C.N. 0105 72 773
MODEL: LS333ANS-2
INPUT VOLTAGE: 12 V AC
UNDERWATER
tighten gland
tapped brackets
luminaire
1.
3. Run Conduit & Water Proof
Connect conduit to conduit entry with suitable
conduit sealant. Use supplied adaptor if necessary.
Run the conduit to the power supply above water
level and ventilate to prevent siphoning.
7. Terminate Luminaire
Firmly tighten cable gland on the inside of
niche to seal cable entry (Figure 2). Connect
to a suitable power supply in accordance with
local wiring rules for connection and location
of supply. Where it is necessary to joint cables
underwater the connections and cables must be
IP68 rated
8. Install Lamp & Test Luminaire
Open luminaire and install lamp as per re-lamping
instructions on next page. Test the luminaire for
correct operation.
Important Note
Do not locate luminaire near heat sources.
Chlorine levels must be kept below 4 parts per
million. Higher levels may cause corrosion to the
luminaire and void warranty.
10.
9. Install Luminaire
Coil free cable inside niche and install luminaire
in niche by screwing long outer cover screws
into niche brackets (Figure 3). Coil cable inside
luminaire with care. Do not double coils over, or
luminaire will be difficult to remove from niche.
4. Install Temporay Shield on Niche
Fit fibreboard shield to opening of
niche before concreting (Figure 1).
Ensure no concrete enters niche.
5. Concrete-in Niche
Encase niche and conduit in concrete. Once in
place, finish surface of pool flush with front of
niche.
6. Concrete-in Niche
Feed cable into niche, allowing sufficient free
cable in niche to allow the luminaire to be placed
on the poolside for re-lamping and maintenance.
A maximum of 1.3 m of cable can be coiled
inside the niche.
2. Installation Preparation
Locate niche in pool and wire to
reinforcing bars.
The 20 mm conduit entry
should be at top of niche (Figure
1). Although some variation is
accommodated by the outer cover
system on the luminaire, care
should be taken to position the
niche level and to allow for pool
finishing materials.
fibreboard shield
finished surface
reinforcing bars
concrete
AVOID HIGH
CHLORINE LEVELS
NO POWER
TOOLS
WARNING
DANGER
ISOLATE LUMINAIRE FROM POWER
Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
The luminaire should only be used
complete with its protective
shield (cover)
Do not shorten, interfere or
disconnect cable from luminaire.
Warranty will be void if cable
assembly is tampered with.
WARNING
Figure 3
Figure 2
Figure 1
INSTALL AWAY FROM
OTHER HEAT SOURCES
Power supply must be isolated prior to connection
or disconnection of cables. Failure to do so will
result in damage to the luminaire components.
Installation Preparation
To aid installation of the cable the number of elbows
and bends should be kept to a bare minimum. Also,
using 25 mm conduit is highly recommended. Check
cable length required, taking into account voltage
drop and distance to transformer. NOTE: In Australia,
each luminaire must be installed as detailed in
AS3000 Clause 6.4.4.5
IN0040 - 23 October 2013
Copyright ©2013 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
WARNING - To reduce the risk of FIRE or INJURY:
1. Luminaires and transformers to be installed by licensed electrical contractors.
2. Luminaires to be used for intended purpose only.
3. Do not operate the luminaires with a missing or damaged parts.
4. Use only genuine Lumascape parts to replace damaged or missing components.
5. Refer to instructions for installation and operating requirements.
6. Ensure installation complies with local regulations
Voltage insulation test (megger) will permanently damage product and will void warranty.
SAVE THESE INSTRUCTIONS.
SAFETY INSTRUCTIONS
Questions?
Call +61 7 3286 2299
Email [email protected]
www.lumascape.com.au
RELAMPING
1. Remove lamp gimbal from body of luminaire. Gently pull on the lamp holder
leads to remove heatshield/lamp assembly from gimbal ring (fig 4).
2. Once removed, take the rim of the lamp between your thumb and forefinger.
The slots provided in the heatshield allow for ease of grip. Pull to remove
lamp.
to lampholder
terminal block
mounting bracket
terminal block
thermal cutout
IMPORTANT
When installing or re-lamping, the thermal cutout MUST be repositioned
beneath the terminal block mounting bracket, within the LS333ANS-2
luminaire (refer fig 3). Failure to do this will cause the luminaire to cycle.
Figure 5
Figure 4
heatshield/lamp
gimbal ring