manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Power Distribution Unit
  8. •
  9. M-system M6DBS User manual

M-system M6DBS User manual

This manual suits for next models

3

Popular Power Distribution Unit manuals by other brands

Lightcorp Nik installation instructions

Lightcorp

Lightcorp Nik installation instructions

hager SP 015 User instructions

hager

hager SP 015 User instructions

Pakedge PowerPak 9 user guide

Pakedge

Pakedge PowerPak 9 user guide

Pts 9042 Series installation guide

Pts

Pts 9042 Series installation guide

Shure WA405 user guide

Shure

Shure WA405 user guide

CORNING CCH 4U quick start guide

CORNING

CORNING CCH 4U quick start guide

Panamax M4LT-EX datasheet

Panamax

Panamax M4LT-EX datasheet

PANCONNECT FLAT 3M Assembly instruction

PANCONNECT

PANCONNECT FLAT 3M Assembly instruction

Raytheon 138-118 manual

Raytheon

Raytheon 138-118 manual

StarTech.com RKPW161915 Spec sheet

StarTech.com

StarTech.com RKPW161915 Spec sheet

D&R ELECTRONICS PDU-6SS user manual

D&R ELECTRONICS

D&R ELECTRONICS PDU-6SS user manual

Botex PSA 322-6 DL quick start guide

Botex

Botex PSA 322-6 DL quick start guide

GE QuiXtra 4000 Assembly and mounting instructions

GE

GE QuiXtra 4000 Assembly and mounting instructions

Vertiv Knürr DI-Strip Rack PDU manual

Vertiv

Vertiv Knürr DI-Strip Rack PDU manual

ABB PSBS0065 Instruction handbook

ABB

ABB PSBS0065 Instruction handbook

Baumuller BFN 3-1-0007-001 Instruction handbook

Baumuller

Baumuller BFN 3-1-0007-001 Instruction handbook

Eaton StructuredWiringSolutions ESWT41600 Instruction leaflet

Eaton

Eaton StructuredWiringSolutions ESWT41600 Instruction leaflet

GE GEK-45404F instructions

GE

GE GEK-45404F instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7845 Rev.6 P. 1 / 4
INSTRUCTION MANUAL
INSTALLATION BASE MODEL M6DBS
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Installation base..................................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +55°C
(-4 to +131°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
• Keep space of at less 1 cm (0.4 inches) on the left side of
the power supply module (model: M6-PSM).
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
COMPONENT IDENTIFICATION
■FRONT VIEW
12
1
Power Supply
Module
Signal
Conditioner
28
• M6DBS-08A
• • • •
8
• M6DBS-08, M6DBS-08P
Signal Conditioner or
Power Supply Module
• • • •
Install signal conditioners from the slot at either end.
Power Supply Modules (M6DPS1 or M6DPS2) could be
mounted at any slots, however, installing them at either end
is generally recommended.
Power Supply Module, M6-PSM must be mounted on the
power module slot of the M6DBS-08A.
M6DBS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7845 Rev.6 P. 2 / 4
INSTALLATION unit: mm (inch)
■MOUNTING DIRECTION
The unit must be mounted on a vertical panel. Mounting
in any other angle will cause internal temperature to rise,
may shorten the product’s life expectation or deteriorate its
performance.
Panel ceiling or wiring conduit (height ≤ 50 mm or 2 in.)
M6DBS
Panel bottom or wiring conduit (height ≤ 50 mm or 2 in.)
10
(.39)
10
(.39)
14
(.55)
40 (1.6)
■DIN RAIL MOUNTING
DIN Rail
(35 mm wide)
DIN Rail Adaptor
Set the base so that its DIN
rail adaptor is at the bottom.
Pull down the adaptors. Posi-
tion the upper hook at the rear
side of the base on the DIN rail
and push back the adaptors
into the original position.
■SURFACE MOUNTING
3-M4
• M6DBS-08A
24.4 (.96)
24.4 (.96)
11.8 (.46)
n-M4
*1
• M6DBS-08A + M6DBS-08P
• M6DBS-08
• M6DBS-08 + M6DBS-08P
3-M4
n-M4
*1
11.8
(.46)
37 (1.46) 37 (1.46)37 (1.46)37 (1.46)
70 (2.76)
70 (2.76)
70 (2.76)
70 (2.76)
37 (1.46)
37 (1.46)
14 (.55)
14 (.55)
14 (.55)
14 (.55)
*1. n = (Number of bases) x 3
M6DBS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7845 Rev.6 P. 3 / 4
■HOW TO MOUNT SIGNAL CONDITIONERS
1) Remove the connector cover (A) at the bottom of the sig-
nal conditioner.
2) Align its concave portion (B) with the convex portion of
the base.
3) Push in the unit until its lower part (C) is firmly secured
on the base by the DIN rail adaptor.
B
C
5678
1234
A
■HOW TO REMOVE SIGNAL CONDITIONERS
Pull out the unit while pushing down the DIN rail adaptor
with a minus screwdriver.
■HOW TO ATTACH AN EXTENSION BASE
1) Remove the connector cover at the right side of the exist-
ing base and put it on the connector of the extension base.
2) Push the extension base into the right end of the existing
base.
Existing Base
Extension Base
■HOW TO DETACH AN EXTENSION BASE
Pull out the extension base while pushing the hooks at the
top and the bottom.
M6DBS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7845 Rev.6 P. 4 / 4
EXTERNAL DIMENSIONS unit: mm (inch)
72 (2.83)
37 (1.46)
3 (.12)
■
M6DBS-08A
■
M6DBS-08, M6DBS-08P
27 (1.06)
16 (.63)
49 (1.93)
37 (1.46)
11.5 (.45)
14 (.55)
24.4 (.96)
27 (1.06)
22.5 (.89)
116 (4.57)
DIN RAIL
35mm wide
DIN RAIL
35mm wide
[5 (.20)]
14
(.55)
49 (1.93)
[3 (.12)]
3–4.5 (.18) dia. MTG HOLE
2 (.08) deep
70 (2.76)
99 (3.90)5 (.20)
5 (.20)
116 (4.57)
22.5 (.89)
[5 (.20)]
14
(.55)
49 (1.93)
3–4.5 (.18) dia. MTG HOLE
2 (.08) deep
24.4 (.96)
14 (.55)
70 (2.76)
99 (3.90)5 (.20)
5 (.20)
[3 (.12)]