EM-2475 P. 1 / 2
INSTRUCTION MANUAL
CURRENT LOOP SUPPLY
(non isolated) MODEL M5D
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (module + shortcircuit wire)................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES OR UK LEGISLATION
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may affect
the protection level of this unit when it is integrated in
a panel system. The user may have to review the CE or
UKCA requirements in regard to the whole system and
employ additional protective measures to ensure the CE
or UKCA conformity.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 1W
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 0 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations. For 24V DC power supply line,
choose a surge protector with its maximum surge voltage
40V or less between lines. Recommended M-System mod-
el: MDP-D24.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Power LED
Terminal Cover
Body
Specifications
Short Circuit
Wire
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
A
B
DIN Rail
■REMOVING THE UNIT
A)Push down the DIN rail adaptor using a minus screw-
driver.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
A
C
B
Spring Loaded
DIN Rail Adaptor
M5D
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2475 P. 2 / 2
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the
connection diagram on the front of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
94 (3.70)3 (.12)
25 (.98) 41 (1.61) [3.3 (.13)]
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 (.29)
12
34
56
78
■CONNECTION DIAGRAM
5
6
1
2
4
3
*Use either output 1 or output 2.
Shortcircuit the unused output.
** Be sure to match specifications of smart transmitter
when using output 2.
7
8
−
+
–
+
+
−
POWER
OUTPUT 1
+
–
OUTPUT 2
+
–
*
**
2-WIRE
TRANSMITTER
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Power Supply manuals

M-system Mini-M M2DNY User manual

M-system

M-system Mini-M M2DNY User manual

M-system Current Loop Supply M3LDY User manual

M-system

M-system Current Loop Supply M3LDY User manual

M-system M5DY-5-M User manual

M-system

M-system M5DY-5-M User manual

M-system JPS3 User manual

M-system

M-system JPS3 User manual

M-system M8DY User manual

M-system

M-system M8DY User manual

M-system 10DNY User manual

M-system

M-system 10DNY User manual

M-system Current Loop Supply M3LDY User manual

M-system

M-system Current Loop Supply M3LDY User manual

M-system DS User manual

M-system

M-system DS User manual

M-system M5DYH2 User manual

M-system

M-system M5DYH2 User manual

M-system R8-PS1 User manual

M-system

M-system R8-PS1 User manual

M-system MDC6 User manual

M-system

M-system MDC6 User manual

M-system JPS3 User manual

M-system

M-system JPS3 User manual

M-system M5TS Series User manual

M-system

M-system M5TS Series User manual

M-system 18KDY User manual

M-system

M-system 18KDY User manual

M-system KWDNY User manual

M-system

M-system KWDNY User manual

M-system R3S-YV4 User manual

M-system

M-system R3S-YV4 User manual

M-system MDC7 User manual

M-system

M-system MDC7 User manual

M-system 18KDYH2 User manual

M-system

M-system 18KDYH2 User manual

M-system W2DYH2 User manual

M-system

M-system W2DYH2 User manual

M-system 18DU User manual

M-system

M-system 18DU User manual

M-system ABF3 User manual

M-system

M-system ABF3 User manual

M-system R3-PS3 User manual

M-system

M-system R3-PS3 User manual

M-system M5DY User manual

M-system

M-system M5DY User manual

M-system M6SDY User manual

M-system

M-system M6SDY User manual

Popular Power Supply manuals by other brands

Altronix LPS5C24X manual

Altronix

Altronix LPS5C24X manual

EFLOW eFlow102N Series installation guide

EFLOW

EFLOW eFlow102N Series installation guide

EFLOW eFlow 104N Series installation guide

EFLOW

EFLOW eFlow 104N Series installation guide

OCI BDL800IR instruction manual

OCI

OCI BDL800IR instruction manual

Puls CPS20.481 installation manual

Puls

Puls CPS20.481 installation manual

Hyelec HY3002 user manual

Hyelec

Hyelec HY3002 user manual

urmet domus 789 manual

urmet domus

urmet domus 789 manual

VICOR PFC Micro user guide

VICOR

VICOR PFC Micro user guide

Magenta Mini Dense Pack MultiView Series Quick reference & setup guide

Magenta

Magenta Mini Dense Pack MultiView Series Quick reference & setup guide

Atrix MPS-H-3 Series user manual

Atrix

Atrix MPS-H-3 Series user manual

Akyga AK-TB-21 user manual

Akyga

Akyga AK-TB-21 user manual

StarTech.com ATXPOW350DF Instruction guide

StarTech.com

StarTech.com ATXPOW350DF Instruction guide

BASETech LB-153 operating instructions

BASETech

BASETech LB-153 operating instructions

Tektronix 1101A instruction manual

Tektronix

Tektronix 1101A instruction manual

Wiesenfield WIE-EF-480 user manual

Wiesenfield

Wiesenfield WIE-EF-480 user manual

NEC Consolidated Power Supply Unit Configuration guide

NEC

NEC Consolidated Power Supply Unit Configuration guide

Ametek Sorensen XDL 56-4P Operation manual

Ametek

Ametek Sorensen XDL 56-4P Operation manual

Rockwell Automation SLC 500 Thermocouple installation instructions

Rockwell Automation

Rockwell Automation SLC 500 Thermocouple installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.