5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8940 Rev.1 P. 1 / 4
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
DC voltage output module..................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
DC VOLTAGE OUTPUT MODULE
(4 points, isolated, tension clamp terminal block) MODEL R3S-YV4
R3S-YV4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8940 Rev.1 P. 2 / 4
COMPONENT IDENTIFICATION
1
20
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
■ FRONT VIEW ■ SIDE VIEW
ERR LED
RUN LED
Output
Hold
Output 2 (SW1)
or
Output 4 (SW2)
Range
Output 1 (SW1)
or
Output 3 (SW2)
Functions
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Green LED turns on in normal operating
conditions.
■SIDE DIP SW
(*) Factory setting
• Output Range: SW1, SW2
OUTPUT 1 (SW1) OUTPUT 2 (SW1)
RANGEOUTPUT 3 (SW2) OUTPUT 4 (SW2)
12345678
OFF OFF OFF OFF OFF OFF OFF OFF
-10 – +10V DC (*)
ON
OFF OFF OFF
ON
OFF OFF OFF
-5 – +5V DC
OFF
ON
OFF OFF OFF
ON
OFF OFF
1 – +1V DC
ON ON
OFF OFF
ON ON
OFF OFF
0 – 10V DC
OFF OFF
ON
OFF OFF OFF
ON
OFF
0 – 5V DC
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1 – 5V DC
OFF
ON ON
OFF OFF
ON ON
OFF
0 – 1V DC
• Output Hold: SW3-1
SW OUTPUT HOLD
HOLD (*)OFF
SW3-1 OFF ON
Note: Be sure to set unused SW3-2 through 3-4 to OFF.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Adjust -320.00 to +320.00 0.00
Full Adjust -32000 to +32000 1.0000
Unused 0: Enable
1: Disable
0: Enable
R3S-YV4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8940 Rev.1 P. 3 / 4
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
20
130 (5.12)
27.5 (1.08) 109 (4.29)
120 (4.72)
POSITIONING
GUIDE
■CONNECTION DIAGRAM
INTERNAL BUS A
*1INTERNAL BUS B
*1. For dual redundant communication.
*2. To use shield line, connect it to SLD terminal and ground the terminal 20.
Note: Do not connect wide span and narrow span simultaneously within the same
channel. Do not use void terminals.
1
INTERNAL POWER
+
–
+
WIDE SPAN
NARROW SPAN
OUTPUT 1
3
2
5+
–
+
WIDE SPAN
NARROW SPAN
OUTPUT 2
7
6
11
+
–
+
WIDE SPAN
NARROW SPAN
OUTPUT 3
13
12
15
+
–
+
WIDE SPAN
NARROW SPAN
OUTPUT 4
17
16
SLD
SLD
SLD
SLD
SLD
SLD
*2
4
8
18
19
20
14
BUS CONNECTOR
■Wide Span: -10 – +10 V DC, -5 – +5 V DC, 0 – 10 V DC,
0 – 5 V DC, 1 – 5 V DC
■Narrow Span: -1 – +1 V, 0 – 1 V DC
R3S-YV4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8940 Rev.1 P. 4 / 4
WIRING INSTRUCTIONS
■APPLICABLE WIRE SIZE
• Solid: 0.2 to 1.0 mm2(0.55 to 1.12 dia.)
• Stranded: 0.2 to 1.5 mm2
(Tinning wire ends may cause contact failure and therefore
is not recommended.)
• Ferruled:
Unsheathed: 0.25 to 1.5 mm2
Sheathed: 0.25 to 0.75 mm2
• Expose wire conductors by 10 mm (0.39”).
Stripped length
10mm
■CONNECTION PROCEDURE
Insert the wire end until it comes to a full stop while push-
ing slot with the tip of a screw driver as shown below. Be
sure wire insulation is not inside the terminal.
Screw Driver
Power wire
OUTPUT PIN ASSIGNMENT
PIN No. FUNCTION
1 VH1
2 COM1
3 VL1
4 SLD
5 VH2
6 COM2
7 VL2
8 SLD
9 NC
10 NC
11 VH3
12 COM3
13 VL3
14 SLD
15 VH4
16 COM4
17 VL4
18 SLD
19 SLD
20 SLD
FUNCTIONS
■OUTPUT HOLD or OUTPUT OFF
In normal conditions, the module outputs the signal from
the preferred bus A.
When an error is detected, the output is switched to the
data from the bus B.
• Output Hold
If both are in error, the module holds the signal and stands
by until one of the communications recovers.
• Output OFF
If both are in error, the module outputs -15 % (or approx.
-11.5 V) and stands by until one of the communications re-
covers.
At the startup, it outputs -15 % (or approx. -11.5 V) until the
communication is established and normal data is received.

Other M-system Power Supply manuals

M-system MDC User manual

M-system

M-system MDC User manual

M-system Current Loop Supply M3LDY User manual

M-system

M-system Current Loop Supply M3LDY User manual

M-system JPS3 User manual

M-system

M-system JPS3 User manual

M-system R3-PS1 User manual

M-system

M-system R3-PS1 User manual

M-system R3-PS3 User manual

M-system

M-system R3-PS3 User manual

M-system M5DY User manual

M-system

M-system M5DY User manual

M-system Mini-M M2DNY User manual

M-system

M-system Mini-M M2DNY User manual

M-system M5D User manual

M-system

M-system M5D User manual

M-system W2DYH2 User manual

M-system

M-system W2DYH2 User manual

M-system JPS3 User manual

M-system

M-system JPS3 User manual

M-system Current Loop Supply M3LDY User manual

M-system

M-system Current Loop Supply M3LDY User manual

M-system 18KDY User manual

M-system

M-system 18KDY User manual

M-system 10DYH2 User manual

M-system

M-system 10DYH2 User manual

M-system 18DU User manual

M-system

M-system 18DU User manual

M-system 18DY User manual

M-system

M-system 18DY User manual

M-system R5-PS1 User manual

M-system

M-system R5-PS1 User manual

M-system M5DYH2 User manual

M-system

M-system M5DYH2 User manual

M-system ABF3 User manual

M-system

M-system ABF3 User manual

M-system M6SDY User manual

M-system

M-system M6SDY User manual

M-system M3DY User manual

M-system

M-system M3DY User manual

M-system Mini-M M2DYS User manual

M-system

M-system Mini-M M2DYS User manual

M-system KWDNY User manual

M-system

M-system KWDNY User manual

M-system M5DY-5-M User manual

M-system

M-system M5DY-5-M User manual

M-system Mini-M M2DYH User manual

M-system

M-system Mini-M M2DYH User manual

Popular Power Supply manuals by other brands

Array electronic 3645A user manual

Array electronic

Array electronic 3645A user manual

ITW Simco-Ion IQ Power HL Installation and operating instructions

ITW

ITW Simco-Ion IQ Power HL Installation and operating instructions

Skyrc SK100157 instruction manual

Skyrc

Skyrc SK100157 instruction manual

Diamond Systems JMM-5312-APK user manual

Diamond Systems

Diamond Systems JMM-5312-APK user manual

W&T GT-86121-1224-W2E manual

W&T

W&T GT-86121-1224-W2E manual

XPG CYBERCORE PLATINUM Series quick start guide

XPG

XPG CYBERCORE PLATINUM Series quick start guide

XPG Core Reactor Gold Series quick start guide

XPG

XPG Core Reactor Gold Series quick start guide

Helios ICT Platinum Series instruction manual

Helios

Helios ICT Platinum Series instruction manual

GW Instek PSB-2000 series user manual

GW Instek

GW Instek PSB-2000 series user manual

PeakTech 6181 Operation manual

PeakTech

PeakTech 6181 Operation manual

Kramer VA-101P12 user manual

Kramer

Kramer VA-101P12 user manual

Belden Hirschmann PC150/36V/48V-IP67 Description and operating instructions

Belden

Belden Hirschmann PC150/36V/48V-IP67 Description and operating instructions

DABBSSON DBS1300 user manual

DABBSSON

DABBSSON DBS1300 user manual

INIM Electronics SmartLevel SPS24060G Installation and programming manual

INIM Electronics

INIM Electronics SmartLevel SPS24060G Installation and programming manual

Extron electronics PS 124 installation manual

Extron electronics

Extron electronics PS 124 installation manual

EPS PS 8016-20 DT instruction manual

EPS

EPS PS 8016-20 DT instruction manual

Bailey infi 90 Modular Power System II Instruction

Bailey

Bailey infi 90 Modular Power System II Instruction

GRAUPNER PRX-4A operating manual

GRAUPNER

GRAUPNER PRX-4A operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.