5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8359 Rev.5 P. 1 / 2
INSTRUCTION MANUAL
POWER SUPPLY MODULE
(single slot, continuous output current 750 mA) MODEL R3-PS1
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Power supply module ..........................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
85 – 132V AC rating: 85 – 132V, 47 – 66 Hz, approx. 45VA
170 – 264V AC rating: 170 – 264V, 47 – 66 Hz, approx. 45VA
24V DC rating: 24V ±10%, approx. 29W or 1.2A at 24V
110V DC rating: 85 – 150V, approx. 29W or 270mA at 110V
■GENERAL PRECAUTIONS
• Before you remove the unit from its base or mount it, turn
off the power supply for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
For heat dissipation, install the power supply module into
the rightmost slot or leftmost slot. For redundant power
system, install two modules in series into the rightmost slot
or leftmost slot. If there is no problem, the rightmost slot
is recommended.
In case of redundant power system use, be sure to install
two same current capacity power supply modules (model:
R3-PS1) in series. The combination of different current ca-
pacity power supply module or interface module with power
supply is not available.
COMPONENT IDENTIFICATION
■FRONT VIEW
1
2
3
4
5
6
Power LED
Power LED: Green LED turns on when the power is sup-
plied.
R3-PS1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8359 Rev.5 P. 2 / 2
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
2
3
4
5
6
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
6-M3
SCREW
6.2
(.24)
■CONNECTION DIAGRAM
INTERNAL
POWER
2
3
6
U (+)
V (–)
FG
POWER INPUT
BUS CONNECTOR
1
4
RUN +
RUN –
RUN CONTACT
OUTPUT
*1
*1. RUN contact is available with Ver.1. 01 or higher versions.
*2. In order to improve EMC performance, bond the FG terminal
to the ground.
Caution: This terminal is NOT a protective conductor terminal.
*2
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.75 – 1.25 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)

Other M-system Power Supply manuals

M-system R3Y-SS16N User manual

M-system

M-system R3Y-SS16N User manual

M-system JPS3 User manual

M-system

M-system JPS3 User manual

M-system 18DY User manual

M-system

M-system 18DY User manual

M-system Mini-M M2DYH User manual

M-system

M-system Mini-M M2DYH User manual

M-system M5DYH2 User manual

M-system

M-system M5DYH2 User manual

M-system Mini-M M2DYS User manual

M-system

M-system Mini-M M2DYS User manual

M-system 18KDYH2 User manual

M-system

M-system 18KDYH2 User manual

M-system M5D User manual

M-system

M-system M5D User manual

M-system R3-PS3 User manual

M-system

M-system R3-PS3 User manual

M-system JPS3 User manual

M-system

M-system JPS3 User manual

M-system 10DYH2 User manual

M-system

M-system 10DYH2 User manual

M-system MDC6 User manual

M-system

M-system MDC6 User manual

M-system M5DY User manual

M-system

M-system M5DY User manual

M-system M5DY-5-M User manual

M-system

M-system M5DY-5-M User manual

M-system MDC7 User manual

M-system

M-system MDC7 User manual

M-system 18KDY User manual

M-system

M-system 18KDY User manual

M-system 10DNY User manual

M-system

M-system 10DNY User manual

M-system ABF3 User manual

M-system

M-system ABF3 User manual

M-system 18DU User manual

M-system

M-system 18DU User manual

M-system Mini-M M2DNY User manual

M-system

M-system Mini-M M2DNY User manual

M-system M6SDY User manual

M-system

M-system M6SDY User manual

M-system W2DYH2 User manual

M-system

M-system W2DYH2 User manual

M-system Current Loop Supply M3LDY User manual

M-system

M-system Current Loop Supply M3LDY User manual

M-system R5-PS1 User manual

M-system

M-system R5-PS1 User manual

Popular Power Supply manuals by other brands

Extreme Networks Alpine 3804 Installation note

Extreme Networks

Extreme Networks Alpine 3804 Installation note

Velleman LABPS6015SM user manual

Velleman

Velleman LABPS6015SM user manual

Xantrex APG-HPD operating manual

Xantrex

Xantrex APG-HPD operating manual

Puls FPT500.241-001-102 installation manual

Puls

Puls FPT500.241-001-102 installation manual

xtpower XT-600Wh user manual

xtpower

xtpower XT-600Wh user manual

Altronix R1224DC16CBV installation guide

Altronix

Altronix R1224DC16CBV installation guide

Rigol DP800 Series manual

Rigol

Rigol DP800 Series manual

SOMFY 9018244 installation guide

SOMFY

SOMFY 9018244 installation guide

Pulsar PSBS 5024C manual

Pulsar

Pulsar PSBS 5024C manual

Niles iPower AC-8CX Installation & operation guide

Niles

Niles iPower AC-8CX Installation & operation guide

Setty EMX-070124 quick start guide

Setty

Setty EMX-070124 quick start guide

Upsite Environmental Monitoring System 400 quick start guide

Upsite

Upsite Environmental Monitoring System 400 quick start guide

PS Audio Power Plant P1000 Operation manual

PS Audio

PS Audio Power Plant P1000 Operation manual

Telecom RPS-1230-SWM quick start guide

Telecom

Telecom RPS-1230-SWM quick start guide

Kikusui PAT-TM Series Setup guide

Kikusui

Kikusui PAT-TM Series Setup guide

Rosewill PHOTON 550 user manual

Rosewill

Rosewill PHOTON 550 user manual

ZALMAN ZM400-GV user manual

ZALMAN

ZALMAN ZM400-GV user manual

TOOQ TQEP-500SSE user manual

TOOQ

TOOQ TQEP-500SSE user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.