manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transducer
  8. •
  9. M-system 18HZ User manual

M-system 18HZ User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1870 Rev.1 P. 1 / 3
INSTRUCTION MANUAL
FREQUENCY TRANSDUCER MODEL 18HZ
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 60mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT VIEW (with cover open)
Span Adj.
Zero Adj.
1
78
56
2
34
INSTALLATION
Use Standard Rack (model: 18BXx or 18KBXx).
18HZ
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1870 Rev.1 P. 2 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■EXTERNAL DIMENSIONS unit: mm (inch)
110 (4.33 )
93 (3.66)
24 (.94)
7 (.28)
78 (3.07)32 (1.26)
8–M3.5
SCREW
7 (.28)
2–M3
SCREW
■CONNECTION DIAGRAM
12
V
U
v
u
FUSE VT
SOURCE
1
2
+
–
OUTPUT 2
POWER
OUTPUT 1
OUTPUT 2
5
6
CONNECTOR
■TERMINAL ASSIGNMENTS
12
34
78
56
18HZ
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1870 Rev.1 P. 3 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 18BXx or 18KBXx). For the DC power source, be
sure that the ripple level is within 10% p-p.
3) Input: Check that the input shows within 85 – 120% of
the rated voltage.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT 1
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
5) No need of adjustments for the Output 2.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Transducer manuals

M-system BPV User manual

M-system

M-system BPV User manual

M-system LT-UNIT Series User manual

M-system

M-system LT-UNIT Series User manual

M-system L3CK User manual

M-system

M-system L3CK User manual

M-system LWT User manual

M-system

M-system LWT User manual

M-system 18PF User manual

M-system

M-system 18PF User manual

M-system TPV User manual

M-system

M-system TPV User manual

M-system LT-UNIT Series User manual

M-system

M-system LT-UNIT Series User manual

M-system LECA User manual

M-system

M-system LECA User manual

M-system PV User manual

M-system

M-system PV User manual

M-system L2PA User manual

M-system

M-system L2PA User manual

M-system 18PA User manual

M-system

M-system 18PA User manual

M-system LTHZ User manual

M-system

M-system LTHZ User manual

M-system KUWEN User manual

M-system

M-system KUWEN User manual

M-system LTCE User manual

M-system

M-system LTCE User manual

M-system Mini-M M2PV User manual

M-system

M-system Mini-M M2PV User manual

M-system 18PV User manual

M-system

M-system 18PV User manual

M-system LTCE User manual

M-system

M-system LTCE User manual

M-system W2PV User manual

M-system

M-system W2PV User manual

M-system LTWTN User manual

M-system

M-system LTWTN User manual

M-system L3PK User manual

M-system

M-system L3PK User manual

M-system M5XWTU User manual

M-system

M-system M5XWTU User manual

M-system HVPN User manual

M-system

M-system HVPN User manual

M-system 18RP User manual

M-system

M-system 18RP User manual

M-system LTCNE User manual

M-system

M-system LTCNE User manual

Popular Transducer manuals by other brands

DFE TrueTension TI17C instruction manual

DFE

DFE TrueTension TI17C instruction manual

Meggitt Whittaker C173255-1 Maintenance manual

Meggitt

Meggitt Whittaker C173255-1 Maintenance manual

Balluff BTL5-C/E1 Series Condensed guide

Balluff

Balluff BTL5-C/E1 Series Condensed guide

NK TECHNOLOGIES ATQ Series instructions

NK TECHNOLOGIES

NK TECHNOLOGIES ATQ Series instructions

MTS Systems Temposonics II LDT Installation and instruction manual

MTS Systems

MTS Systems Temposonics II LDT Installation and instruction manual

Humminbird transducer manual 

Humminbird

Humminbird transducer manual 

Siedle Novotechnik TH1 CANopen user manual

Siedle

Siedle Novotechnik TH1 CANopen user manual

Nexus NX Wireless Wind Transducer set Installation and operation manual

Nexus

Nexus NX Wireless Wind Transducer set Installation and operation manual

CTC Union IFC-CCF40 Quick installation guide

CTC Union

CTC Union IFC-CCF40 Quick installation guide

Leviton ODC0P-00W Product data

Leviton

Leviton ODC0P-00W Product data

MAMAC SYSTEMS HU-224 installation instructions

MAMAC SYSTEMS

MAMAC SYSTEMS HU-224 installation instructions

CONTINENTAL CONTROL SYSTEMS WattNode Pulse Quick install guide

CONTINENTAL CONTROL SYSTEMS

CONTINENTAL CONTROL SYSTEMS WattNode Pulse Quick install guide

Camille Bauer SINEAX I 552 operating instructions

Camille Bauer

Camille Bauer SINEAX I 552 operating instructions

Dwyer Instruments 2200 Series Installation and operating instructions

Dwyer Instruments

Dwyer Instruments 2200 Series Installation and operating instructions

Dwyer Instruments IS626 Series Installation and operating instructions

Dwyer Instruments

Dwyer Instruments IS626 Series Installation and operating instructions

WIKA WUD-2x-E operating instructions

WIKA

WIKA WUD-2x-E operating instructions

FIAMA MAT2 User manual and maintenance

FIAMA

FIAMA MAT2 User manual and maintenance

Ultrasound Technologies Fetatrack 310 Service manual

Ultrasound Technologies

Ultrasound Technologies Fetatrack 310 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.