BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 35mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT VIEW (with cover open)
+–
Span Adj.
Zero Adj.
INSTALLATION
Use Standard Rack (model: 18BXx or 18KBXx).
18PV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1820 Rev.4 P. 2 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■EXTERNAL DIMENSIONS unit: mm (inch)
98.6 (3.88)
110 (4.33 )
20 (.79)
23.7 (.93)
PNEUMATIC
CONNECTION
Rc 1/4” or 1/4” NPT
76 (2.99)
14.5 (.57)
33 (1.30)
2–M3 SCREW
NPT
FITTING
20 (.79)27 (1.06)
93 (3.66)
■CONNECTION DIAGRAM
PNEUMATIC
INPUT
OUTPUT 2
+
–
CONNECTOR
POWER
OUTPUT 1
OUTPUT 2
■TERMINAL ASSIGNMENTS
+–
18PV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1820 Rev.4 P. 3 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
PIPING
The pneumatic inlet is female screwed of Rc 1/4” (1/4” NPT
optional with a fitting). Tightening torque is at the maxi-
mum of 12 N·m. Check that there is no air leak at the con-
nection after sealing it.
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 18BXx or 18KBXx). For the DC power source, be
sure that the ripple level is within 10% p-p.
3) Input: Check that there is no air leak at the pneumatic
connection.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT 1
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
5) No need of adjustments for the Output 2.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Transducer manuals

M-system LTCE User manual

M-system

M-system LTCE User manual

M-system W2PV User manual

M-system

M-system W2PV User manual

M-system L2PA User manual

M-system

M-system L2PA User manual

M-system L3CK User manual

M-system

M-system L3CK User manual

M-system LT-UNIT Series User manual

M-system

M-system LT-UNIT Series User manual

M-system L2CA User manual

M-system

M-system L2CA User manual

M-system LTHZ User manual

M-system

M-system LTHZ User manual

M-system 18PF User manual

M-system

M-system 18PF User manual

M-system M5XWTU User manual

M-system

M-system M5XWTU User manual

M-system BPV User manual

M-system

M-system BPV User manual

M-system LWT User manual

M-system

M-system LWT User manual

M-system TPV User manual

M-system

M-system TPV User manual

M-system Mini-M M2PV User manual

M-system

M-system Mini-M M2PV User manual

M-system LTWTN User manual

M-system

M-system LTWTN User manual

M-system LECA User manual

M-system

M-system LECA User manual

M-system LTCE User manual

M-system

M-system LTCE User manual

M-system 18HZ User manual

M-system

M-system 18HZ User manual

M-system KUWEN User manual

M-system

M-system KUWEN User manual

M-system LT-UNIT Series User manual

M-system

M-system LT-UNIT Series User manual

M-system LTCNE User manual

M-system

M-system LTCNE User manual

M-system 18PA User manual

M-system

M-system 18PA User manual

M-system L3PK User manual

M-system

M-system L3PK User manual

M-system 18RP User manual

M-system

M-system 18RP User manual

M-system PV User manual

M-system

M-system PV User manual

Popular Transducer manuals by other brands

Humminbird ICE HELIX Series installation guide

Humminbird

Humminbird ICE HELIX Series installation guide

ZIEHL TMU100V operating manual

ZIEHL

ZIEHL TMU100V operating manual

Setra Systems 278 installation guide

Setra Systems

Setra Systems 278 installation guide

Camille Bauer SINEAX I 552 operating instructions

Camille Bauer

Camille Bauer SINEAX I 552 operating instructions

Balluff BTL5-T1 Series manual

Balluff

Balluff BTL5-T1 Series manual

Airmar P39 Owner's guide & installation instructions

Airmar

Airmar P39 Owner's guide & installation instructions

Visi-Trak A49-1120P INSTALLATION AND TESTING PROCEDURE

Visi-Trak

Visi-Trak A49-1120P INSTALLATION AND TESTING PROCEDURE

EarthQuake Q10B user manual

EarthQuake

EarthQuake Q10B user manual

Balluff BTL5-T1 Series user guide

Balluff

Balluff BTL5-T1 Series user guide

Humminbird Trolling Motor Transducer installation guide

Humminbird

Humminbird Trolling Motor Transducer installation guide

Mianyang Weibo Electronic WB Series user manual

Mianyang Weibo Electronic

Mianyang Weibo Electronic WB Series user manual

Lowrance SpotlightScan installation manual

Lowrance

Lowrance SpotlightScan installation manual

Novatech Bitronics PowerPlex II user manual

Novatech

Novatech Bitronics PowerPlex II user manual

Setra Systems 269 installation guide

Setra Systems

Setra Systems 269 installation guide

Airmar B45 Owner's guide & installation instructions

Airmar

Airmar B45 Owner's guide & installation instructions

MAMAC SYSTEMS HU-224 installation guide

MAMAC SYSTEMS

MAMAC SYSTEMS HU-224 installation guide

Raymarine RV-100 RealVision 3D installation instructions

Raymarine

Raymarine RV-100 RealVision 3D installation instructions

S+S Regeltechnik Thermasgard RTM Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik Thermasgard RTM Operating Instructions, Mounting & Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.