manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transducer
  8. •
  9. M-system LTWTN User manual

M-system LTWTN User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3356 Rev.3 P. 1 / 4
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Watt transducer ..................................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• This equipment is suitable for Pollution Degree 2 and
Measurement Category II (input, transient voltage
4000V). Reinforced insulation (signal input to output:
300V) is maintained. Prior to installation, check that the
insulation class of this unit satisfies the system require-
ments.
• Altitude up to 2000 meters.
• The equipment must be mounted inside a panel.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■GENERAL PRECAUTIONS
• Before you remove or mount the unit, turn off the input
signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 85% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as the input sig-
nal is supplied, however, a warm up for 10 minutes is re-
quired for satisfying complete performance described in
the data sheet.
COMPONENT IDENTIFICATION
Span Adjustment
Zero Adjustment
Connection
Diagram
Body
Specifications
INSTALLATION
■DIN RAIL MOUNTING
Set the unit so that its DIN rail adaptor is at the bottom.
Position the upper hook at the rear side of the unit on the
DIN rail and push in the lower. When removing the unit,
push down the DIN rail adaptor utilizing a minus screw-
driver and pull.
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
■WALL MOUNTING
Refer to “EXTERNAL DIMENSIONS.”
WATT TRANSDUCER
(self-powered) MODEL LTWTN
LTWTN
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3356 Rev.3 P. 2 / 4
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
1 2 3 4 5 6
11 12 13 14 15 16
789
10
54 (2.13)
72 (2.83) [4 (.16)]143 (5.63)
3
(.12)
DIN RAIL
35mm wide
8 (.31)
2–M4 MTG HOLE
98 (3.86)
80 (3.15)
111 (4.37)
16–M4 SCREW
TERMINAL COVER (option /T)
10 (.39)
• When mounting, no extra space is needed between units.
LTWTN
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3356 Rev.3 P. 3 / 4
■CONNECTION DIAGRAM
LOAD
+
–
123
SOURCE
P2V
P1U
v
u
FUSE VT
Vv
P3
Uu
k
l
CT
L
K
1L
1S
3L
3S
k
l
L
K
7
9
8
13
14
5
6
2
PULSE OUTPUT
+
–
11
12
DC OUTPUT
LOAD
12
SOURCE
P2V
P1U
v
u
FUSE VT
k
l
CT
L
K
1L
1S
+
–
7
8
13
14
1
2
PULSE OUTPUT
LOAD
1N2
SOURCE
P0V
P1U
v
u
FUSE VT
Vv
P2
Uu
k
l
CT
L
K
1L
1S
2L
2S
k
l
L
K
+
–
7
9
8
13
14
1
5
6
2
PULSE OUTPUT
LOAD
1N23
SOURCE
P2
V
P1U
v
u
FUSE VT
Vv
P3
Uu
Vv
P0
Uu
k
l
CT
L
K
1L
1S
2L
2S
3L
3S
k
l
L
K
k
l
L
K
+
–
13
14
PULSE OUTPUT
7
8
9
10
1
2
3
4
5
6
+
–
11
12
DC OUTPUT
+
–
11
12
DC OUTPUT
+
–
11
12
DC OUTPUT
■ Open Collector
Pulse Output Connection Example
13
14
+
–
■SINGLE-PHASE/2-WIRE
■SINGLE-PHASE/3-WIRE ■3-PHASE/4-WIRE
■3-PHASE/3-WIRE
1
LTWTN
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3356 Rev.3 P. 4 / 4
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 1.2 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Input: Calculate the calibration range and check that the
result is within the usable range.
Calibration Range [W] = Measuring Wattage
(VT Ratio) × (CT Ratio)
3) DC Output: Check that the load resistance meets the
described specifications.
4) Totalizing pulse output: Check that the load connected to
the open collector output is within 35V DC @100mA.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn on the input signal and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Transducer manuals

M-system KUWEN User manual

M-system

M-system KUWEN User manual

M-system HVPN User manual

M-system

M-system HVPN User manual

M-system BPV User manual

M-system

M-system BPV User manual

M-system LTHZ User manual

M-system

M-system LTHZ User manual

M-system LWT User manual

M-system

M-system LWT User manual

M-system W2PV User manual

M-system

M-system W2PV User manual

M-system L2PA User manual

M-system

M-system L2PA User manual

M-system 18PF User manual

M-system

M-system 18PF User manual

M-system M5XWTU User manual

M-system

M-system M5XWTU User manual

M-system 18PA User manual

M-system

M-system 18PA User manual

M-system L3PK User manual

M-system

M-system L3PK User manual

M-system LTCE User manual

M-system

M-system LTCE User manual

M-system LTCNE User manual

M-system

M-system LTCNE User manual

M-system TPV User manual

M-system

M-system TPV User manual

M-system L2CA User manual

M-system

M-system L2CA User manual

M-system PV User manual

M-system

M-system PV User manual

M-system LTCE User manual

M-system

M-system LTCE User manual

M-system LT-UNIT Series User manual

M-system

M-system LT-UNIT Series User manual

M-system Mini-M M2PV User manual

M-system

M-system Mini-M M2PV User manual

M-system LT-UNIT Series User manual

M-system

M-system LT-UNIT Series User manual

M-system 18RP User manual

M-system

M-system 18RP User manual

M-system 18HZ User manual

M-system

M-system 18HZ User manual

M-system 18PV User manual

M-system

M-system 18PV User manual

M-system LECA User manual

M-system

M-system LECA User manual

Popular Transducer manuals by other brands

Siemens ERN 1387 Assemble & disassemble

Siemens

Siemens ERN 1387 Assemble & disassemble

SSET CE-VJ41 -9MSK-0.5 Series instructions

SSET

SSET CE-VJ41 -9MSK-0.5 Series instructions

Lowrance Active Imaging 3-IN-1 installation manual

Lowrance

Lowrance Active Imaging 3-IN-1 installation manual

MKS Baratron 122B instruction manual

MKS

MKS Baratron 122B instruction manual

Lumel P43 user manual

Lumel

Lumel P43 user manual

Sutron ACCUBAR 5600-0120-2 Operation & maintenance manual

Sutron

Sutron ACCUBAR 5600-0120-2 Operation & maintenance manual

Thyracont VSM77PN operating instructions

Thyracont

Thyracont VSM77PN operating instructions

Balluff BTL6-U110-M****-PF-S4 series Condensed guide

Balluff

Balluff BTL6-U110-M****-PF-S4 series Condensed guide

Veris Industries EP3 Series installation guide

Veris Industries

Veris Industries EP3 Series installation guide

MG LTRPN instruction manual

MG

MG LTRPN instruction manual

LEM ITZ 2000-SPR FLEX ULTRASTAB manual

LEM

LEM ITZ 2000-SPR FLEX ULTRASTAB manual

Simrad 50-200 COMBI C -  REV D datasheet

Simrad

Simrad 50-200 COMBI C - REV D datasheet

Agilent Technologies IMG-300 instruction manual

Agilent Technologies

Agilent Technologies IMG-300 instruction manual

TR-Electronic LMP-30-750 PB manual

TR-Electronic

TR-Electronic LMP-30-750 PB manual

S+S Regeltechnik THERMASGARD MWTM-I Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik THERMASGARD MWTM-I Operating Instructions, Mounting & Installation

Siedle Novotechnik TP1 CANopen manual

Siedle

Siedle Novotechnik TP1 CANopen manual

MAMAC SYSTEMS PR-274 technical information

MAMAC SYSTEMS

MAMAC SYSTEMS PR-274 technical information

Airmar B60 installation instructions

Airmar

Airmar B60 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.