M2I TOPRT-Ex Series User manual

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 1 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Thank you for purchasing the industrial HMI touch panel series of M2I corporation.
Please read this manual carefully to know installing, wiring, operating this equipment for safe use of this
product.
M2I Corporation
Industrial HMI Touch Panel
TOPRT -Ex Series
Hardware Manual

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 2 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Index
Index .................................................................................................................................................................................................................. 2
Chapter 1 Safety Precautions................................................................................................................................................................. 3
Chapter 2 Overview.................................................................................................................................................................................... 5
2.1 Introduction of Products.............................................................................................................................................. 5
2.2 Package Contents............................................................................................................................................................ 5
2.3 Explanation of Model name ....................................................................................................................................... 6
Chapter 3 General Specifications......................................................................................................................................................... 6
3.1 Electrical Specifications................................................................................................................................................. 6
3.2 Display Specifications .................................................................................................................................................... 7
3.3 Touch Specifications....................................................................................................................................................... 7
3.4 Sub Function Specifications (*Premium models only) ................................................................................... 7
3.5 Memory Specifications.................................................................................................................................................. 7
3.6 Environment Specifications......................................................................................................................................... 7
3.7 Structure Specifications ................................................................................................................................................ 7
Chapter 4 Part Names and General Specifications...................................................................................................................... 8
4.1 TOPRT1210SD-Ex............................................................................................................................................................. 8
4.2 TOPRT1230XD-Ex / TOPRT1240XD-Ex................................................................................................................... 9
4.3 TOPRT12-Ex Series-Rear Part Names and Specifications ...........................................................................11
4.4 TOPRT12-Ex Series- Side Part Names and Specifications..........................................................................11
4.5 TOPRT12-Ex Series- Top Part Names and Specifications...........................................................................11
4.6 TOPRT12-Ex Series- Bottom Part Names and Specifications ...................................................................12
Chapter 5 External Device Interface..................................................................................................................................................12
5.1 Serial Interface ................................................................................................................................................................12
5.2 Ethernet Communication Specifications .............................................................................................................13
5.3 USB Interface ...................................................................................................................................................................14
Chapter 6 Installation...............................................................................................................................................................................15
6.1 Installation Requirement ............................................................................................................................................15
6.2 TOPRP Assemble............................................................................................................................................................15
6.3 Installation Procedure..................................................................................................................................................16
6.4 Front USB...........................................................................................................................................................................18
Chapter 7 Wiring........................................................................................................................................................................................18
7.1 Power wiring ....................................................................................................................................................................18
7.2 Ground wiring .................................................................................................................................................................19
7.3 Cable Clamp Installation ............................................................................................................................................20
Chapter 8 Maintenance ..........................................................................................................................................................................21
8.1 Cleaning the Display ....................................................................................................................................................21
8.2 Periodic Check Points..................................................................................................................................................21
8.3 Problems with the Device..........................................................................................................................................21
8.4 Setting System Recovery Mode..............................................................................................................................21
Chapter 9 Product and Warning Label............................................................................................................................................22
Chapter 10 Product Label......................................................................................................................................................................23

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 3 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Chapter 1 Safety Precautions
■Before using the product
To use the product safely and effectively, please read the contents of this manual thoroughly before use. Please
keep to the safety precaution, for it is to prevent accidents and potential danger from occurring. Safety precaution
is classified into ‘Warning’ and ‘Caution’ and their meanings are as follows. Also the indicated illustrations on the
product and in the manual have the following meanings.
Violating the instruction may result in serious personal injury or death.
Violating the instruction may result in slight personal injury or product damage.
Be cautious, for danger may be present.
Be cautious, for there is a possibility of an electric shock.
■Anti-Explosion Precautions
Do not open the product when explosive gas is around.
All cables connected with the product should not be connected or disconnected when the power of product
is on.
Do not change SD Card when the power is connected to product.
■General Precautions
Do not press the screen with a hard or sharp object (awl, screwdriver, pen) with too strong a force.
It may cause malfunction of touch due to damage of the front sheet.
Do not use or store in an environment with high vibration.
Do not allow foreign objects such as water, liquids, or metal powders to enter the product. This may cause
breakage or electric shock.
Use the radio or mobile phone at least 30cm away from the main unit.
Two or fewer bright spots may appear on the LCD screen, and certain areas may appear brighter, but this is
not a defect in LCD characteristics.
Do not store or operate in direct sunlight. Direct sunlight can change the properties of the LCD.
■Design Precautions
Install protection circuit on the outside of Products to protect the entire control system when external power
supply or Products have problems.
As the malfunction & incorrect result of Products could damage the stability of the entire systems and human
body, you must install damage preventing interlock circuit such as emergency stop, Protective circuits,
positioning upper and lower limit switch and interlock for forward/reverse operation.
When a computer or other controllers communicate and exchange data with products or change operation
mode of products, set up protective sequence program in PC or Controller for protecting system from
communication error.
The output signal or communication lines should be separated from the power line or high tension wire.
They should be installed 100mm (3.94 Inch) or more from each other.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 4 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
■Wiring Precautions
Be sure the wiring is done correctly by checking the product’s rated voltage and the terminal layout. Incorrect
wiring could result in fire, damage or malfunctions.
Tighten the terminal screw with the specified torque. If the screws of terminal are loose, it could result in
short circuit, fire, malfunctions.
FG Terminal must be used a dedicated ground. Not doing so could result in malfunctions.
a. Grounding should be the Class 3 grounding. The cable for grounding should be more than 2㎟.
b. grounding point be closed to the products and make short the distance to the ground cable if possible.
Please see below.
■Installation Precaution
Do not install the location which exceeds allowed temperature. Product can be damaged or shorten the life.
Especially Install environment as below should be avoided.
Do not Install product to the place which the ambient temperature is out of limits, from -10℃ to 50℃ or on
the surface of control board which high pressure equipment is installed.
Do not install to the place where strong shock or vibration continuously have impacted on product.
For indoor use only.
Use the product under 2000M altitude.
The length of the power cable must be no more than 3 m (10 feet).
■Disposal Precaution
When you dispose of product and battery, please treat it as industrial waste. It can create poisonous substances
or explosion.
■Battery Specification
Mounted on mainboard Model CTL920F Battery is not replaced by the user. If the battery has run out of service,
please contact our Customer Support Center for replacement and inspection.
Item
Content
Battery Voltage
DC 2.3V , 7.7mAh
Battery Model
CTL920F (lithium Rechargeable / non-exchangeable )
Battery Lifetime
Permanent (In case of ambient temperature 25℃)
*The specifications are subject to change depending on the model.
■All field-wiring connections to this unit shall be from Limited Voltage / Limited Current, below 20~28 Vdc
isolated secondary source with an output fuse, or Class 2 secondary circuits.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 5 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Chapter 2 Overview
2.1 Introduction of Products
This industrial HMI touch panel is an industrial control device required in industrial field. It is a device based on
RS-232C and RS-422/485, Ethernet which is used for the basic purpose of communication with another device
(PLC).
2.2 Package Contents
The components of the product are as follows.
Before using the product, please check that all of the following components are included.
Item
Figure
Quantity
Product and User Manual
1
Gasket
1
Mounting Clamp
10
Power Connector and COM3
communication connector
1
USB Cable Clamp
Cable Tie
1
Accessories
(Sold separate)
USB Memory
USB Cable
SD Card
Front Protect Sheet
User Option

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 6 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
2.3 Explanation of Model name
TOPR
T
□□
□□
□
□
-
Ex
□□
Series
Type
Screen
Option
Resolution
Power
-
Anti-Explosion
Reserve
P: Process
08: 8.4"
10: TOPRP10D
+ TOPRD **10*
Q: QVGA(320*240)
D: DC
Ex:: Explosion proof or
special model
Customer option:
No relate to anti-
explosion
D: Display
10: 10.4"
20: TOPRP10D
+ TOPRD **20*
V: VGA(640*480)
A: AC
Blank: Non-explosion
proof or general model
T: P + D
12: 12.1"
30: TOPRP10D
+ TOPRD **30*
S: XGA(800*600)
15: 15.0"
40: TOPRP50D
+ TOPRD **30*
X: XGA(1024*768)
* EX model of
1210" has "S" for
XGA
** TOPRT1210SD-Ex is combined by TOPRP10D and TOPRD1220X.
2.3.1 Process Module (Main Unit)
TOPR
P
□□
□
Series
Type
Option
Power
P: Process
10: Standard
D: DC
T: P + D
50: Standard(10) + Performance improvement
2.3.2 Display Module (Accessory Unit)
TOPR
D
□□
□□
□
Series
Type
Screen
Option
Resolution
D: Display
08: 8.4”
10: Standard
Q: QVGA(320*240)
10:10.4"
20: Premium
V: VGA(640*480)
12: 12.1”
30: "20" Premium + Added Function/Option
S: SVGA(800*600)
15: 15.0”
X: XGA(1024*768)
Chapter 3 General Specifications
3.1 Electrical Specifications
Rated voltage
Powered by Process
12V, 3.3V
Power
Consumption
Process Module
TOPRP10D
9W or less
TOPRP50D
Display Module
TOPRD1220X
6W or less
TOPRD1230X
9W or less
TOPRT1210SD-Ex (TOPRP10D + TOPRD1220X)
15W or less
TOPRT1230XD-Ex (TOPRP10D + TOPRD1230X)
18W or less
TOPRT1240XD-Ex (TOPRP50D + TOPRD1230X)
18W or less

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 7 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
3.2 Display Specifications
Color
16M Colors
Brightness Level
10 Level(by software)
Backlight Type
LED
Backlight Life
50,000 hours
Display Font
MS Windows Vector font possible Image font
Front LED Indicate
Built in
3.3 Touch Specifications
Part
Specification
Model
Touch Type
Built-in, Analog resistive touch sensor
TOPRT ** 10 /30/ 40
3.4 Sub Function Specifications (*Premium models only)
Part
Specification
Model
Front Camera
Built-in, Resolution: VGA(640*480)
TOPRT ** 10 / 30 / 40
Proximity Sensor
Built-in, Sensing Distance 0.7M
TOPRT ** 10 / 30 / 40
Brightness Sensor
Built-in, Brightness controls automatically as 10 level
TOPRT ** 10 / 30 / 40
IrDA
Built-in, 0.7M, Exclusive products only
TOPRT ** 30 / 40
3.5 Memory Specifications
Screen Memory
128MB
Backup Memory
512KB: System buffer(10K Word),Including Alarm/Log/Recipe
Backup Period
Permanent
Real Time Clock
Built in(by Battery)
3.6 Environment Specifications
Operation Temperature(℃)
-10 ~ +50
Storage Temperature(℃)
-20 ~ +60
Operation Humidity(%RH)
0 ~ 90(No dew)
Atmosphere
No corrosive gas
Protection Classification
Front IP54, Rear IP2X)
3.7 Structure Specifications
Cooling System
Natural air circulation
Case Material
AL(Aluminum)

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 8 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Chapter 4 Part Names and General Specifications
4.1 TOPRT1210SD-Ex
4.1.1 TOPRT1210SD-Ex External Dimension
Product
A(mm)
B(mm)
C(mm)
D(mm)
TOPRT1210SD-Ex
320
261
5
66.5

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 9 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
4.1.2 TOPRT1210SD-Ex Front Part Names and Specifications
No.
Part
Description
Support Model
①
Power LED
System Power Status LED
Common
②
Proximity Sensor
Automatically backlight ON/OFF by sensing object coming
Option
③
Brightness Sensor
Automatically brightness controls by ambient brightness
Option
④
USB OTG
UP/Down load project file
Common
⑤
Camera
Resolution VGA(640*480)
Option
⑥
LCD Panel
TFT 16M Color LCD
Common
⑦
Touch Panel
Analog resistive touch sensor
Common
⑧
USB OTG Cover
Front USB OTG cover hole
Common
4.2 TOPRT1230XD-Ex / TOPRT1240XD-Ex

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 10 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
4.2.1 TOPRT1230XD-Ex / TOPRT1240XD-Ex External Dimension
Product
A(mm)
B(mm)
C(mm)
D(mm)
TOPRT1230XD-Ex
320
261
5
66.5
TOPRT1240XD-Ex
320
261
5
66.5
4.2.2 TOPRT1230XD-Ex / TOPRT1240XD-Ex Front Part Names and Specifications
No.
Part
Description
Support Model
①
Power LED
System power status LED
Common
②
Proximity Sensor
Automatically backlight ON/OFF by sensing object coming
Common
③
IR Sensor
Device for communication with dedicated equipment
Common
④
Brightness Sensor
Automatically brightness controls by ambient brightness
Common
⑤
Camera
Resolution VGA (640*480)
Option
⑥
LCD Panel
TFT 16M Color LCD
Common
⑦
Touch Panel
Analog / Capacitive resistive touch sensor
Option
⑧
USB Cover
Front USB cover hole
Common
⑨
USB OTG
Program upload or download
Common

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 11 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
4.3 TOPRT12-Ex Series-Rear Part Names and Specifications
No.
Part
Form
Description
①
Power Connector
TB 5mm 3P
Power Supply for Product(DC 20V~28V)
②
COM3 Connector
TB 3.5mm 3P
RS-485 Serial Communication Connector
③
Extension Connector
-
Expansion module mounting cover
4.4 TOPRT12-Ex Series- Side Part Names and Specifications
4.5 TOPRT12-Ex Series- Top Part Names and Specifications
No.
Part
Form
Description
Etc.
①
External antenna connector
SMA FEMALE
External antenna connector
Option
②
SD Card Cover
Plastic Cover
SD Card, Reset Switch, Mode Switch included
③
SD Card Socket
SD Card Socket
Data upload / download
④
Cover Sensor
Photo coupler
Cover open / close detection
⑤
Mode Switch
DIP Switch 2P
Set Up System Mode
⑥
Reset Switch
Tact Switch
System reset Switch
No.
Part
Form
Description
Model
①
USB HOST
A Type x 2ch.
Connector for option for USB storage. 5V/0.5A limit
TOPRT1210SD-Ex
TOPRT1230XD-Ex
Connector for option for USB storage. 5V/0.9A limit
TOPRT1240XD-Ex

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 12 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
4.6 TOPRT12-Ex Series- Bottom Part Names and Specifications
No
Part
Form
Description
Model
①
Ethernet Connector
RJ45 x 2ch
10BASE-T/100BASE-TX, Auto-MDIX
TOPRT1210SD-Ex
TOPRT1230XD-Ex
10BASE-T/100BASE-TX/1000BASE-T, Auto-MDIX
TOPRT1240XD-Ex
②
COM1
DSUB9
(female)
RS-232C/422/485 communication port
(Switchable the Comm. Software select)
Common
③
COM2
DSUB9
(female)
RS-232C/422/485 communication port
(Switchable the Comm. Software select)
Common
Chapter 5 External Device Interface
In order for the main unit to communicate with an external device, please check below contents.
5.1 Serial Interface
5.1.1 RS-232C
Items
Contents
Protocol
Full Duplex
Synch
Asynchronous
Communication Distance
About 15m
Type of Connection
1:1
Control Code
ASCII Code or HEXA Code
Transmission Speed
2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200, 187500 bps
Data Type
Data Bit
7, 8 bit
Parity Bit
NONE, ODD, EVEN Parity
Stop Bit
1, 2 bit
Modular Jack
DSUB 9Pin
5.1.2 RS-422/485
Items
Contents
Protocol
Full Duplex / Half Duplex
Synch
Asynchronous
Communication Distance
About 500m
Type of Connection
1:N (N ≤31)
Control Code
ASCII Code or HEXA Code
Transmission Speed
2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200, 187500bps
Data Type
Data Bit
7, 8 bit
Parity Bit
NONE, ODD, EVEN Parity
Stop Bit
1, 2 bit
Modular Jack
DSUB 9Pin

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 13 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
5.1.3 COM1 Connector pin number and Signal name
Type
Pin No.
Signal
Direction
Meaning
9Pin Female
1
RDA(RD+)
Input
RS-422/485Data Receive(+)
2
RD(RxD)
Input
RS-232C Data Receive
3
SD(TxD)
Output
RS-232C Data Send
4
RDB(RD-)
Input
RS-422/485Data Receive(-)
5
SG
-
Signal Ground
6
SDA(SD+)
Output
RS-422/485Data Send(+)
7
VCC *1
-
+5V, 0.2A
8
N.C
-
N.C
9
SDB(SD-)
Output
RS-422/485Data Send(-)
*1) If VCC is required for an external device, connect pin 7(+ 5.0V) and pin 5. (* 0.2A output)
5.1.4 COM2 Connector pin number and Signal name
Type
Pin No.
Signal
Direction
Meaning
9Pin Female
1
RDA(RD+)
Input
RS-422/485 Data Receive(+)
2
RD(RxD)
Input
RS-232C Data Receive
3
SD(TxD)
Output
RS-232C Data Send
4
RDB(RD-)
Input
RS-422/485 Data Receive(-)
5
SG
-
Signal Ground
6
SDA(SD+)
Output
RS-422/485 Data Send(+)
7
RTS
Output
RS-232C Send Request Signal
8
CTS
Input
RS-232C Send Available Signal
9
SDB(SD-)
Output
RS-422/485 Data Send(-)
5.1.5 COM3 Connector pin number and Signal name
Type
Pin No.
Signal
Direction
Description
1
D+
I/O
RS-485 Data (+)
2
D-
I/O
RS-485 Data (-)
3
SG
-
Signal Ground
* Be sure to connect the RD and SD to the RS-232C communication line by crossing each other with a Twisted Pair Cable.
Please connect SG directly.
* RS-422/485 communication line must use RDA and RDB as Twisted Pair Cable, SDA and SDB as Twisted Pair Cable.
5.2 Ethernet Communication Specifications
5.2.1 Ethernet
Item
Description
Ethernet
Method
TOPRT1210SD-Ex
IEEE802.3i/IEEE802.3u, 10BaseT / 100BaseT
TOPRT1230XD-Ex, TOPRT1240XD-Ex
IEEE802.3i/IEEE802.3u/IEEE802.3ab,
10BASE-T/100BASE-TX/1000BASE-T
Speed
TOPRT1210SD-Ex
10M / 100Mbps
TOPRT1230XD-Ex, TOPRT1240XD-Ex
10M / 100Mbps / 1Gbps
Communication Method
Base Band
Switching Method
AUTO MDIX
Maximum Segment Length
100M (Hub between product)

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 14 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Communication Cable
UTP (Unshielded Twisted Pair)
Modular Jack
RJ45 x 2ch
5.2.2 RJ-45 Pin Layout
Type
Pin No.
Color
10M/100MHz
1GHz
Model
1
Orange/White
TD+
BI_DA+
Common
2
Orange
TD-
BI_DA-
Common
3
Green/White
RD+
BI_DB+
Common
4
Blue
Unused
BI_DC+
TOPRT1240XD-Ex
5
Blue/White
Unused
BI_DC-
TOPRT1240XD-Ex
6
Green
RD-
BI_DB-
Common
7
Brown/White
Unused
BI_DD+
TOPRT1240XD-Ex
8
Brown
Unused
BI_DD-
TOPRT1240XD-Ex
* When HUB is used, Straight cable should be used.
Ex) Straight Cable Wiring: Connect 1:1 according to the wiring diagram above.
* In case of connected directly without HUB, Cross Cable should be used.
Ex) Cross Cable Wiring: In the above wiring diagram, TD+ and RD+ are changed, and TD- and RD- are exchanged.
5.3 USB Interface
5.3.1 USB Host
Type
Items
Specifications
USB
Interface
TOPRT1210SD-Ex
EHCI/OHCI Specification Version 1.0, USB2.0/1.1 Compatible
TOPRT1230XD-Ex
TOPRT1240XD-Ex
EHCI/OHCI Specification Version 1.0, USB3.0/2.0/1.1
Compatible
Communication Method
Control/Bulk
Transfer
Speed
TOPRT1210SD-Ex
Max. 480Mb/s
TOPRT1230XD-Ex
TOPRT1240XD-Ex
Max. 5Gb/s
Support Device
USB Storage (FAT16/FAT32 Format Available)
Connector Type
Type A(2ch)
5.3.2 USB Device
Type
Items
Specifications
USB Interface
USB 2.0
Communication Method
Interrupt/Bulk/Isochronous
Transfer Speed
480Mb/s
Supported OS
Windows 98SE/2000/XP/VISTA/7/10(32/64bit)
Cable Length
1.5m
Connector Type
Micro USB AB, Female
Connection Method
Through USB Connector on Front Side of Display Module

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 15 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Chapter 6 Installation
6.1 Installation Requirement
(1) It should be installed within -10 ~ 50°C and 10~80% relative-humidity, otherwise the screen may be changed
or cause malfunction and damage.
(2) Be sure that heat from surrounding equipment does not cause product to exceed its standard operating
temperature.
(3) In order to minimize external mechanical hazards for maintaining anti explosion performance, please control
the mechanical hazards of the surrounding environment.
6.2 TOPRP Assemble
Insert Process Module to Guide of Rear of Display Module and Mount with Bolts included in Package.
(Bolt Size: M4 X 8L, 0.2N.m)
-10 ~ 50°C, 10~80%
-10 ~ 50°C, 10~80%
IP2X
Enclosure
Front
Rear
IP54
Enclosure

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 16 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
6.3 Installation Procedure
Please follow to below instructions to install the product.
6.3.1 Direction
It is recommended that the power connector at the rear is located at the top for vertical installation.
(1) TOPRT1210SD-Ex
(2) TOPRT1230XD-Ex / TOPRT1240XD-Ex
6.3.2 Panel Cut-out
Make a panel cut which product is mounted and insert the TOPR to the panel form the front side.
(1) The Size of Panel Cut (Mounting Place)
Making the Panel Cut (Mounting Size) per each model as below Table, Before Installation.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 17 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Model
A(mm)
B(mm)
C (mm)
TOPRT12 Series
306(+1.0/0)
247(+1.0/0)
1.6~5.0(+1.0)
6.3.3 Fixation
Installation methods should be following by using the supplied installation clamps for IP performance.
(1) Insert the clamp into the slot of the product.
(2) Screw the unit into the panel cut with a screwdriver.
Note: If the clamping screw below is over-tightened, the touch sensor may stop working or malfunction. Tighten
to 0.8N.m screwdriver torque.
Caution: IP performance cannot be secured if the clamp is not tightened with a tightening force of 0.8N.m.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 18 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
6.4 Front USB
6.4.1 Front USB Cover Open/Close
(1) TOPRT1210SD-Ex: Turn left or right the locking screw on the USB cover.
(2) TOPRT1230XD-Ex / TOPRT1240XD-Ex: Place the locking screw or horizontally(Open) or vertically(Close).
TOPRT1210XD-Ex
TOPRT1230/40
6.4.2 Data Upload and Download
You can download or Upload Project file data by connecting USB cable.
TOPRT1210SD-Ex
TOPRT1230XD-Ex / TOPRT1240XD-Ex
※Do not use USB in explosive circumstances. There can be an explosion during operation.
Chapter 7 Wiring
7.1 Power wiring
(1) The Power cable should have the following specification.
Power Cable Specification
0.75~2.5mm2(18~12AWG)
F.G Cable Specification
2mm2(14AWG)
Conductor type
Simple or Stranded wire
Bolt torque
≥0.8N.m
Conductor length
Temperature rating of the field installed conductors
65℃ or under

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 19 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
(2) The Power terminal has following specifications.
Caution: The use of the Pin Terminal(ferrule) when installing the power supply and ground terminal is important
for maintaining the performance of the device. Failure to install power and ground using the same Pin
Terminal(ferrule) as below may cause explosion due to spark due to abnormal cable loss. Therefore, please be
sure to familiarize yourself with how to use Pin Terminal(ferrule) below.
B
L
F
E
D
d
1.8~2.0
22~18
12~14
5
3.3~3.8
2~2.5
(3) Wiring of power is as follows.
7.2 Ground wiring
(1) The product has enough anti-noise measure, so except that there are many noises. Especially, the ground is
not needed. When doing ground, please refer to the followings.
(2) The ground should be the exclusive ground. The ground should be type class 3 ground (ground resistor is
less than 100Ω)
(3) When not doing the exclusive ground, do common ground like figure B.
(4) Use the cable width more than 2mm2. Put the point of the ground near product and shorten Ground line.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation 20 / 23
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,
Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
7.3 Cable Clamp Installation
CAUTION: If you use an extension cable on the USB terminal block, install the cable clamp to prevent the USB
connection from being disconnected or sparking because the cable is disconnected.
(1) Place cable clamp at the screw hole on Rear of the product and turn the screw to fix it.
(2) Insert USB connector to USB port of the product and pass the cable tie through hole of cable clamp.
(3) Tighten cable clamp and USB cable with the cable tie sufficiently and check that the USB connector is not
pulled out by external force.
This manual suits for next models
3
Table of contents