INSTALLATION GUIDE
LINDRIVE SERIES
120-130VAC / 12VDC
Magnitude, Inc. Page 1of 2
14711
Bentley
Circle.
T
ustin,
CA
92780
www
.MagnitudeInc.com
[email protected] DOC-GU-XXX Rev. 1General
This driver is to be installed in accordance with Article 450 of the
National Electric Code. The driver must be installed in a well-ventilated
area free from explosive gases and vapors. Proper operation requires
for free flow of air. This driver should only be installed by a qualied
electrician.
Precautions Before Installing
Check the label and ensure the driver has the proper input voltage and
wattage for the job. Check the wire markings to ensure they match the
wiring diagram on this installation guide.
Quick Specs
Input Voltage 100-130V AC
Output Voltage 12V DC
Max. Ambient Temp. -250C to 450C (-13°F - 113°F)
Enclosure IP21 Dry and Damp
Min. Installation Space
Between Drivers 5” Inch
FOR MODELS
SLT20L12, SLT40L12
Mounting
Select a suitable location capable of supporting the weight of the
driver. Use the two key holes in the wire housing and third hold on the
flange when mounting. It is recommended that the driver be mounted
vertically with the wiring compartment pointing down. Recommended
spacing between drivers is 5”.
5” Min.
Spacing
Half hole