MAK AL-2016A User manual

1

2
USER MANUAL
BEFORE INSTALLING AND USING THIS SYSTEM,
YOU ARE STRONGLY RECOMMENDED TO READ THIS MANUAL CAREFULLY.
MENU
1. Basic Configure- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- (01)
2. Words Explain- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -(02)
3. Attention before using- - - - - - - - - - - - - - - - - - - - - - - - - - - - (03)
4. Feature & Function- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - (04)
5. Main part & instruction- - - - - - - - - - - - - - - - - - - - - - - - - - - - (04)
6. Setting & Operation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -(10)
7. Receive the Alarming phone- - - - - - - - - - - - - - - - - - - - - - - -(19)
8. Remote Control Function- - - - - - - - - - - - - - - - - - - - - - - - - - -(21)
9. System Installation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -(21)
10. Technology Parameter- - - - - - - - - - - - - - - - - - - - - - - - - - - -(22)
11. Normal Fault & Solution- - - - - - - - - - - - - - - - - - - - - - - - - - - -(22)
12. Accessories- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - (23)
1. Basic Configure
AL-2016A

3
2. Word Explain
Arm Set to be Armed(Anti-Burglar), Armed or Make Alarm
Disarm Exit the status of Armed or Stop Alarming
Normal Vocal Arm In Armed status, when being triggered, the siren will be warning and dial the
preset phone number
Mute Arm In Armed status, when being triggered, the siren w ill not be warning but dial
the preset phone number
Stay Arm Setting Armed(Anti-Burglar), User could select the security zone to be
working or not working (After setting, do not affect the normal Arm)
Remote Control Remote Control by the phone to Arm/Disarm or monitor
Phone Line Phone line that could make phone call.
Armed Delay Time from setting Arm to be Armed
Alarm Delay Time from being triggered to Alarm and call.
Warning time of Siren
Warning time of Siren
User Password Password for Disarm or remote control
3. Attention before using
(1) Make sure all the Arming zones are on duty.
(2) Avoid heavy impact and unnecessary disassembly which might incur accident or man-made damage.
(3) When installing, avoid touching the electronics components which on the PCB w ith hand or metal
parts.
(4) When installing, make sure the AC power supply is stable (if the AC power supply is cut, the system
will shift to backup battery automatically).
(5) Suggested: main unit should connect w ith phone line. When connect w ith EXT phone, please set the
phone number as requirement. (For Detail, please read below)
(6) When fault, please contact with the dealer or our factory with Invoice & Warrant Card.
4. Feature & Function
(1) LCD DISPLAY
(2) 80 wireless zones, rolling to learn code. 4 wired zones
Wireless transmitting range is more than 200meters.
(3) USA CPU processing circuits, more stable.

4
(4) Billion Code
(5) Available to connect w ith CMS
(6) Available to set each zone to be ON/OFF
(7) Arm/disarm by remote, 2 groups Auto Arm/Disarm, remote to Arm/Disarm, Arm/Disarm by keypad
(8) 72pcs alarm log, show ing event detail & date (year, month, day, hour, minute).
(9) Available to monitor Local, when alarming.
(10) Self-check Function: easy to test & check, for adding new sensor & normal check
(11) Emergency Function.
(12) Built-in 85dB buzzer.
(13) Easy to select w ired/w ireless PIR sensor, Door Sensor, Gas/Smoke Detector and so on.
(14) 12V output port for wired accessories.
5. Main part & instruction
1) Main unit (front)
1. Pow er
indicator
Always on: On duty
Off: Power off
2. Arm/Disarm
Indicator
Always on: in Armed status
Off: in Disarmed status
3. Low-battery
indicator
Always on: Power voltage is lower than
8±0.2V
Off: Power voltage is normal
4.LCD display Display operating menu and event log
5.Keypad For operating
2) Main unit left, right & back side
(1)Antenna: Pull out for better
signal.
(2)Mike: Monitor local, when
answering Arming phone.
(3)Power socket
4) Built-in Buzzer
5) Backup Battery Cover

5
3) Keypad Button
Button
Enable Function
“ “key
Press“ “key
Cancel and go back. Cancel
“ “key
Press“ “key
Confirm and go to next. Confirm
“↑”key Press“↑”key Move upward, left or backspace. Move &
Backspace
“↓”key Press“↓”key Move downward or right. Move
Number Key:“0”— “9”key。
Set to be armed by
keypad
When mainframe displayed “Welcome”, Press “↑” for 1.5sec., sound “Bi”
once, enter vocal arm status.
4) Main unit (top)
AL-2016A
①Power Button:Power ON/OFF
②Phone port:Connect with phone line or user phone
③Alarming Voltage(12V)output port:Alarming time sy nc with Built-in
Buzzer
④Power(12V)output port:Power for wired accessories.
⑤Wired 4 zone, when connect with one detector, signal wire directly
connect with mainf rame. If more than two, before connect with
mainf rame, please connect the detectors in series.
⑥Wired 3 zone, wiring same as above.
⑦Wired 2 zone, wiring same as above.
⑧Wired 1 zone, wiring same as above.
AL-2016A GSM
Power Button①:Power ON/OFF
SIM card slot②:Insert SIM
G③SM indicator:checking GSM status
GSM Antenna④:For better signal.
⑤EXT-siren (12V) port:Warning time is sync with built-in buzzer.
⑥Power (12V) output port:For wired accessories.
⑦Wired 4 zone (no need resistance);Connecting with one detector,
directly connect signal wire with this port (4), the other one connect
with public port (⊥). If connect with two or more, please connect them
with in series then connect the port.
Wired 3 zone⑧,same as above.
Wired ⑨2 zone,same as above.
Wired ⑩1 zone,same as above.
A: Press “A” to open SIM card slot with something like toothpick.

6
5) Built-in DIP Sw itch:
AL-2016A
NO.
Function Setting
1 ON ON Remotely Control by phone (Def ault is “ON”)
1 OFF
2
ON ON Switch for restoring password (Def ault is “2”), when forgot
password, please open the cov er of mainframe, pull the
switch from “2” to “ON”, then power off, power on after
2sec., pull it to be “2” again. Password restored to be
“000000”
2 OFF
3
ON ON Arm/Disarm dial CMS or not (Def ault is “3”). If pull to “ON”
and input CMS No. & User ID, it will dial CMS, when
Arm/Disarm. Pull to “3”, it will not dial CMS when
Arm/Disarm.
3 OFF
4 Undefined
AL-2016A GSM
NO.
Function Setting
1
ON ON Switch f or restoring password(Def ault is “1”), when
f orgot password, please open the cover of mainf rame,
pull the switch f rom “1” to “ON”, then power off, power
on after 2sec., pull it to be “1” again. Password restored
to be “000000”
1 OFF
2
ON ON Sending SMS & dial CMS or not, when Arm/Disarm
(Def ault is “2”). If pull to “ON” and input CMS No., it will
dial CMS. If no input CMS No., it will send SMS to user.
2 OFF
6) Remote Control
OR
Button Enable/Disable Function
ARM KEY
Press key
Sound “Bi”, enter normal ARM
status. To be
Armed
Press key again
Sound “Bi Bi”, enter mute ARM
status.
DISARM
KEY Press key Disarm immediately & exit
alarming status
To be
Disarmed
EMERGENCY
KEY Press key Warn & Dial at once To be
Emergency
PERIMETER
ARM KEY
Press key
Sound “Bi”, enter perimeter
Armed To be
Perimeter
Armed
Press & key at
the same time
Enter v ocal armed status without
any delay.

7
6. System Setting and Operation
Pow er on, LCD w ill be on, then operating as below:
Ⅰ. NORMAL
(1). PHONE
(2). CMS
(3). PASSWORD
(4). TIME&DATE
Ⅱ. ADVANCED

8
(1). LEARN CODE
(2). REMOVE

9
(3). SETTING
(4). SELF CHECK
(5). ALARM LOG
(6). AUTO ARM/DISARM

10
(7)Default setting
1.Delay to be Armed: 0sec. 5.Built-in Buzzer & EXT Siren:
SYNC.
2.Delay to be Disarmed: 0sec. 6.The 1st zone: Normal Zone
3.When Armed, default is:
Global Armed 7.Alarm Phone default is: Null
4.default password: 000000
7. Receive the Alarming call
In armed status, if any accessories are being triggered, the system will make alarm after delay time.
(1) Warning Alarm
If no connecting with phone line or do not input any number, when being triggered, the siren w ill be
warning in any status.
Except the above two vocal alarming situation, If under mute alarm status, the siren w ill not warn.
(2) Phone Alarm
When alarming, the system w ill dial in order. If not being stopped, it will dial three times in cycle. (As
below)
If connecting with CMS, it w ill dial CMS first and send alarming information. If sent successfully, it w ill
not dial CMS again. If not, it will dial CMS three times. Then dial other three groups in cycle. (As below)
When answer the phone, firstly it is the operating voice prompt. It is available to operate according to the
voice prompt. If the user does some operating, it w ill not dial this number in another cycle.

11
Phone Button Function
Press“3#”key When monitoring the alarming place, it is ok to press “3#” for 20sec more.
Press“5#”key Sw itch into Vocal Alarming and hang up, then dial next number
Press“1#”key Exit current alarming and hang up, But mainframe is still in Armed status, if being
triggered, it will make alarm again.
Press“0#”key Disarm
8. Remote Control Function
Phone Button Function Phone buzzer
Press“0#”key Disarm Sound “Bi Bi” once
Press“1#”key ARM Sound “Bi” once
Press“3#”key Monitor Local Sound “Bi” once
9. System Installing
(1) Before using, all w ireless should learn code. Security zone need to be used, should be “ON”.
(2) For safe and better w ireless signal receiving, the mainframe should install at the center. Mainframe &
wireless accessories should avoid the large metal and strong magnetic region.
(3) When using rechargeable battery, it should be charged for more than 72 hours. Please select battery
from standard manufacturer for normally working.
(4) Wiring diagram for wired accessories as below:

12
AL-2016A
AL-2016A GSM

13
10. Technology Parameter:
(1) Power Voltage:AC:110V ~ 245V
(2) Standby Current of Mainframe:≤35mA
(3) Operating Current:≤120mA
(4) Alarming Current:≤300mA(not connecting w ith EXT siren)
(5) Receiving Frequency:433.92±0.5MHz
(6) Preset Phone Number:3pcs phone number, 1pcs CMS NO and 1pcs User ID
(7) Built-in Siren:>85dB
(8) Standby Time:≥8 hours
(9) Size:20x14.5x6.6cm
(10) Wireless receiving range:≥200M
(11) Triggered wired accessories:When disconnect, it will make alarm.
(12) Triggered duration:0.5sec.
(13) Security Zone:Wireless 80,Wired 4
11. Normal Fault & Solution
Fault The possible reasons Solution
Power LED is OFF,LCD
screen does not work.
Backup batter run out or power
is cut
Charge the battery or recover
power supply.
Wireless signal unavailable same frequency interference Contact dealer for help.
Could not dial, when Alarming
Input wrong phone number or
phone line is disconnected.
Input the number, connect the
phone line.
Transmitting short Have not pulled out the antenna
or close to the big metal object
Pull out the antenna or avoid
closing to the big metal
object.
shorten transmitting of the
detector Battery is low of the detector Replace the battery.

14
11. Accessories Instruction
D-106 / D-102A Door Sensor Instruction
Overview:
D-106 / D-102A Door Sensor using imported CPU, more stable.
D-106 Instruction D-102A Instruction
Technology Parameter:
Battery:12V/23A
Static Current: 0uA;
Transmitting Current: ≤15mA;
Ty pe: ASK;
Transmitting Frequency:433.92MHz;
Transmitting Range:≥200M (clearing)
Usage:(PIC1A)
Learn code:Press SW1 for 3sec.
LED1:Signal sending indicator
LED2:Low power indicator (When under voltage,
it will be always on)
Working Method:(PIC2A)
Magnetic Stripe abuts against Door Sensor
closely, and then takes magnetic stripe away more
than 20mm, LED1 will f lash once, sending warning
signal.
Technology Parameter:
Battery:12V/185MAH;
Static Current: 0uA;
Transmitting Current: ≤12mA;
Ty pe: ASK;
Transmitting Frequency:433.92MHz;
Transmitting Range:≥220M (clearing)
Usage(PIC1B)
Learn code:Press K2 f or 3sec.
LED1:Wireless signal sending indicator
LED2:Low power indicator (When under
v oltage, it will be alway s on)
Working Method:(PIC2B)
Magnetic Stripe abuts against Door Sensor
closely, and then takes magnetic stripe away more
than 20mm, LED1 will f lash once, sending warning
signal.

15
AL-413W / PIR-102A Instruction
1.Overview
AL-413W (PIC1A) / PIR-102A (PIC1B) wall mounting w ireless PIR Detector make up of w ireless
sending circuit & infrared detecting device.
Features:
A. Anti-false alarm & outstanding detecting function.
B. Pure w ireless design, w ireless transmitting, easy installing.
C. Pow er saving design, long working time.
2. Parameter
AL-413W Instruction PIR-102A Instruction
Power:1.5V,7 Alkaline Battery 4pcs
Working Current:static<25uA, being triggered<25mA
(6VDC)
EXT Battery:static<40uA, being triggered<25mA
(12VDC)
Transmitting Frequency:433.92MHz
Transmitting Distance:≥200m (open v iew place)
PIR Detector Diagram (View PIC2A)
Sensor:Germany Hayman Sensor
Detecting angle:horizontal 100° Vertical 70°
Detecting range:6-12m
Size: 10.7*5.8*4.7cm
Working Temp:-10℃ to +40℃
Storage Temp:-25℃ to +55℃
Anti-radiation >1V/M
Anti-v isible light >6500LUX
Power:9V High-powered alkaline battery 1pcs
Working Current:static<25uA, being triggered<25mA
(9VDC)
EXT Battery:static<4u A, being
triggered<25mA(12VDC)
Transmitting Frequency:433.92MHz
Transmitting Distance:≥200m (open v iew place) PIR
Detector Diagram (View PIC2B)
Sensor:Germany Hayman Sensor
Detecting angle:horizontal 100° Vertical 70°
Detecting range:6-12m
Size: 6.7*4.5*5.1cm
Working Temp:-10℃ to +40℃
Storage Temp:-25℃ to +55℃
Anti-radiation >1V/M
Anti-v isible light >6500LUX

16
3.Installation & Usage of Detector
3.1 Installing guide to avoid false alarm
A. Avoid sunshine or strong light
B. Using high-powered alkaline battery
C. Avoid the floating subject, e.g. clothes or curtain, strong wind may cause false alarming.
D. Avoid facing heating unit, such as air conditioner, refrigerator, fan and so on.
3.2 Installing
Use screw to fix the bracket on the wall, about 2.1m to 2.8m from the ground. (PIC3A or PIC3B)
3.3 Working Mode
Detecting Indicator:Detected someone w ithin detecting range, red LED w ill be flashing.
Signal transmitting indicator:When transmitting, Green LED w ill be on for.
Low Voltage:When the voltage of battery is low, the Blue LED w ill be always on (indicating: time to
replace battery).
Check when power on:Every time power on, detector w ill enter 1 min self-check mode, and the
Red LED w ill be flashing. If without being triggered, it w ill enter testing mode.
Code learning mode:Under testing or working mode, press code learning sw itch, the Green LED
will be on for 3sec., then enter code learning mode, enter testing mode after 3sec. (PIC5A or PIC4B)
Selecting working time for detector:Pull to 180S,detector will send signal every 180sec. That is
saving power. Pull to 10s,detector will send signal every 10sec. That is for installing test.
3.4 Walk to test
Walk into detect range, it should flash once, start transmitting w ireless alarm signal.
3.5 Code learning
Firstly, enter code learning status, long press code learning switch (PIC5A or PIC4B), Green
indicator will be always on. When mainframe received that signal, it will sound to indicating code learning
finish. If not, please repeat the above operating.
3.6 EXT Power for AL-413W
It is able to connect with 12V DC Pow er. Please check PIC4A for power socket(Default is
unavailable, unless required by user)

17
4. NOTE
A. Avoid to drop or impacts, or w ill cause damage.
B. Avoid touching sensor to keep mirror surface clean.
C. After testing, please set to normally work mode.
D. Do regularly checking for better status.

18
Table of contents
Popular Security System manuals by other brands

Lorex
Lorex L15LD424-251 Specifications

Honeywell
Honeywell Manning GM-JR Instruction and installation manual

Mobeye
Mobeye i110 user manual

Larson Electronics
Larson Electronics CL1B-MS-1227 quick start guide

Ness Security Products
Ness Security Products SecurityGuardII owner's manual

DSC
DSC Envoy NT9010 v1.0 Programming worksheet